OPERATION
Do not switch power on and off in quick succession as this will damage the compressor and
cause the appliance to fail.
After completing electrical installation, power can be switched on at the mains.
On power up the compressor and fans will start and the internal light should illuminate
(ensure light switch is on).
The temperature is controlled by a thermostat which is factory set at position 3 this should not
need adjusting. The cabinet should be left on at all times
Ensure doors are kept closed when not serving failure to do so will cause the cabinet to
have reduced efficiency and will cause condensation and ice build up on the cooling plate.
If excess ice builds up switch cabinet off and allow it to defrost. Remove any excess water from
inside the cabinet.
MAINTENANCE
Please note; maintenance or cleaning should not be carried out while the appliance is
connected to the power supply.
(Due to electrical regulations only a limited amount of user maintenance can be carried out.)
LIGHT AND STARTER
To replace the lamp and or starter switch, turn the cabinet off and un-plug. Remove the lamp
cover then simply twist lamp/starter to remove, replace new in reverse.
CLEANING
Both the interior and exterior can be wiped cleaned with a warm damp cloth do not use
abrasive cream cleaners.
For sliding door cabinets the door channels should be wiped clean every week and any spillage
should be removed immediately
All other maintenance should be carried out by a properly trained and qualified person.
It is recommended that the condenser is cleaned at least once every 12 months. Access is
from the rear of the cabinet by the removal of the right cover panel. The condenser should be
brushed with a stiff brush and debris should be removed with a vacuum cleaner.
Note the
cabinet should be disconnected from the supply before any panel is removed. Failure to
remove the cabinet can result in the warranty being made void.
DISPOSAL
The crossed out wheeled bin symbol means that within the European Union the product must
be taken to a licensed disposal recycling facility.
Do not dispose of these products as unsorted municipal waste.