input
output
L E N
L E N
engine start
DC fuse
as close to
battery as
possible
AC input:
230V/50-60Hz (check model)
Continuous through current
Max 16A AC on 1600
Shore power / gen set
110V/50-60Hz (check model)
Continuous through current
Max 32A AC on 1600
Shore power / gen set
FUSES
Quick Installation
House / Domestic
+ + +
L E N
AC INPUT
(SHORE POWER)
+ + +
L E N
AC OUTPUT
( to consumer unit
with RCD )
DC –
DC +
1
6
7
8
DC low voltage
AC high voltage
Warning:
3
4
11
9
10
2
Alarm
(alarms on box )
fuse
10A
+ + +
+ + +
input
output
AC 230V
power in
AC power out
AC 110V
power in
AC power out
L E N
L E N
R.C.D. /
Earth Leak Detector
Please be aware that fuses are there mainly to protect your cabling, not the device.
L=Live
E=Earth
N=Netural
When the Combi is in inverter mode the
‘through the box’ earth line is
automatically disconnected from the
input earth and joined to the output
neutral. This complies with neutral
earth inverter requirements. If you wish
to maintain a through earth simply
connect the input earth and output
earth.
Auxiliary
Charging
Output
up to 5A
Main
Charging
Output
When ordering the wire using one cable is always best. However, you can add up smaller cable’s mm
sq to equal the equivalent larger size. For example, if you want 100mm sq using 2x50mm sq would be
ample, likewise with 3x 33mm sq etc.. Do not forget that each cable shall need fusing at half (or a third
etc) of the single cable rating, its not safe to put multiple cables on a single fuse .
AC Cable 110V
12 AWG 3.5mmsq 30A
10 AWG 5.0mmsq 50A
AC Cable 230V
2.5mmsq for 16A
3.5mmsq for 30A
DC Cable Sizes and Fuses
NEG POS
5
12
4
2
3
AC input
AC output
MODEL
DC Fuse size Cable size (0 -1.5m) Cable size (1.5 -4.0m)
PCSP(A)121600
200A
50mm2 / 0 AWG
70mm2 / 00 AWG
PCSP(A)241600
150A
35mm2 / 2 AWG
50mm2 / 0 AWG
1) AC input from shore.
7) Rotary switch for battery chemistry selection.
2) Fuse for inverter only (inside) non resettable.
8) Auxiliary charging output (positive only).
3) AC output to your RCD and distribution box.
9) DC negative battery connection.
4) Fuse resettable for through power protection.
10) DC Positive only.
5) Auxiliary charge power board (optional).
11) Reverse polarity tell-tale, warranty void if damaged.
6) Remote port for connecting the remote control.
12) Not Applicable