Sterling Power PCSP121600 Manual Download Page 3

+ + +

+ + +

input

output

L E N

L E N

 

engine start

 

 

 

 

DC fuse

as close to 

battery as

 possible

AC input:

230V/50-60Hz (check model)
Continuous through current 
Max 16A AC on 1600  
Shore power / gen set

110V/50-60Hz (check model)
Continuous through current 
Max 32A AC on 1600  
Shore power / gen set

FUSES

Quick Installation

House / Domestic

+ + +

L  E  N

AC INPUT

(SHORE POWER)

+ + +

L  E  N

AC OUTPUT

( to consumer unit

with RCD )

DC – 

DC +

1

6

7

8

DC low voltage                         

AC high voltage

Warning: 

3

4

11

9

10

2

Alarm
(alarms on box )

fuse
10A

+ + +

+ + +

input

output

AC 230V

 

power in

AC power out

AC 110V 

power in

AC power out

L E N

L E N

R.C.D. /

Earth Leak Detector

Please be aware that fuses are there mainly to protect your cabling, not the device. 

L=Live
E=Earth
N=Netural

When the Combi is in inverter mode the 
‘through  the  box’  earth  line  is 
automatically  disconnected  from  the 
input  earth  and  joined  to  the  output 
neutral.  This  complies  with  neutral 
earth inverter requirements. If you wish 
to  maintain  a  through  earth  simply 
connect  the  input  earth  and  output
earth.   

Auxiliary

Charging 

Output

up to 5A

Main

Charging 

Output

When ordering the wire using one cable is always best. However, you can add up smaller cable’s mm 
sq to equal the equivalent larger size. For example, if you want 100mm sq using 2x50mm sq would be 
ample, likewise with 3x 33mm sq etc.. Do not forget that each cable shall need fusing at half (or a third 
etc) of the single cable rating, its not safe to put multiple  cables on a single fuse . 

AC Cable 110V

12 AWG 3.5mmsq 30A
10 AWG 5.0mmsq 50A

AC Cable 230V

2.5mmsq for 16A
3.5mmsq for 30A

DC Cable Sizes and Fuses

NEG       POS

5

12

4

2

3

AC input

AC output

MODEL

DC Fuse size  Cable size (0 -1.5m) Cable size (1.5 -4.0m)

PCSP(A)121600

200A

50mm2 / 0 AWG

70mm2 / 00 AWG

PCSP(A)241600

150A

35mm2 / 2 AWG

50mm2 / 0 AWG

1)   AC input from shore. 

7) Rotary switch for battery chemistry selection.

2)   Fuse for inverter only (inside) non resettable. 

8)  Auxiliary charging output (positive only).

3)   AC output to your RCD and distribution box.

9)  DC negative battery connection.

4)   Fuse resettable for through power protection. 

10) DC Positive only. 

5)   Auxiliary charge power board (optional). 

11) Reverse polarity tell-tale, warranty void if damaged.

6)   Remote port for connecting the remote control.

12) Not Applicable

Summary of Contents for PCSP121600

Page 1: ...erators from 1 10 KW have poor regulators and produce erratic wave forms when presented with a inductive load The wave form is simply not good enough to run the Combi in battery charger mode However o...

Page 2: ...st unexpected switching off Remove battery connections and ensure unit is off If repair is required only use original parts General safety and installation precautions WARNING these units are heavy do...

Page 3: ...Charging Output up to 5A Main Charging Output When ordering the wire using one cable is always best However you can add up smaller cable s mm sq to equal the equivalent larger size For example if you...

Page 4: ...24V charging terminal that shall generally be connected to the starter cranking battery to keep it topped up It shall charge at a voltage slightly lower 0 3V than the main Combi output It is a trickl...

Page 5: ...only available and due to the high power of the combi the low power supply will not operate the product The solution The Combi S has a power reduction ability for example the 1600 model at 230V would...

Page 6: ...overload Over temperature Back voltage F Flash F Power saver auto mode Power saver off Charge only on Charge on Flash Charge only Inverter Inverter on Alarm alarms on box 1 2 3 Combined pure sine wav...

Page 7: ...rger function This mode consumes 0 000Awhen off Power Saver Off This is very similar to Auto mode However the inverter shall remain online regardless of the load on the AC side For example if a mobile...

Page 8: ...ake care of the matter promptly and at no expense to you This only applies for shipping which was undertaken by our company and does not apply for shipping organised by yourself Please do not throw ou...

Page 9: ...Garantie ACHTUNG FFNEN SIE DAS GER T NICHT HOHE SPANNUNG LESEN SIE DIE ANLEITUNG VOR DER INSTALLATION UND VOR DEM BETRIEB NUR VON PERSONEN MIT FACHKENNTNIS D RFEN DAS GER T INSTALLIEREN Im Wechselric...

Page 10: ...tallation Anschluss Schema Sicherungen und Kabel Seite 4 Installation Installationsroutine Batterieprofile Desulfatierungs Modus Zus tzlicher optionaler Ladeausgang Kombi Betrieb Seite 5 Installation...

Page 11: ...se E Schutz leiter N Neutral Arbeitet das Ger t im Wechselrichter Modus dann wird der Neutral Leiter mit dem Schutzleiter verbunden um die Funktion des FI Schalters zu gew hrleisten Optionaler Ladeaus...

Page 12: ...Kappe nach unten F r den 230V AC Anschluss schrauben Sie die Schraube c d heraus Die Schraube c liegt unter der DC Abdeckkappe Um an die AC Anschl sse zu gelangen muss zuerst die DC Kappe entfernt wer...

Page 13: ...IN Fernbedienung ja Frontpanel Leistung der Spannungsumschaltung 16A Unterspannung 4 110V 230V 90V 190V Minimale Spannung 4 110V 230V 95V 194V berspannung 4 110V 230V 125V 263V Reaktivierung nach S 4...

Page 14: ...d Made in Taiwan 1 2 3 4 5 6 7 8 9 LED Information Spezifikation LED Anzeige Dauer Alarmton Alarmton alle 5 Sekunden Fernbedienungs LEDs Identischer Alarmton wie Ger t Maximalstromladung Ausgleichslad...

Page 15: ...e mode Flashing Charger ON float charge mode Unit over temperature trip Inverter overload trip Power save ON inverter ON charger OFF Aux 12V output charger active Aux 24V output charger active AC Inpu...

Page 16: ...b alle Sicherungen funktionieren und nicht durchgebrannt sind Auch Korrosion kann erheblichen Einfluss auf den Stromfluss haben Ein und Ausschalten des Ger tes mit einer Pause von mindestens 10 Sekund...

Reviews: