5.0 TROUBLESHOOTING
6.0 ILLUSTRATIONS
3
ITEM
5.1
SYMPTOM
Emitter™ Does Not Light
RECOMMENDED ACTION
(in order of priority)
1. Ensure that fixture cover is affixed to base and that it trips the interlock switch.
2. Ensure that on/off switch is set to
on
.
3. Turn off power for 10 seconds, and then turn power back on.
4. Replace Emitter with known working Emitter. Normal replacements recommended
once per year.
5. Check line voltage.
6. Check wiring to Emitter.
7. Replace power supply.
5.2
Low Output (Radiometer Reading)
or Visibly Weak Light
1. Replace Emitter with known working Emitter.
2. Check line voltage.
3. Check wiring to Emitter.
5.3 Red/Orange
Light
1. Check ambient temperature. If the temperature is at or below 35°F, Emitter is too
cold to operate properly.
2. If ambient temperature is in excess of 35°F, follow actions for the
Low Output symptom.