background image

WARRANTY

This Steren product is warranted under normal usage against defects in 

workmanship and materials to the original purchaser for one year from the 

date of purchase.

CONDITIONS

1.- This warranty card with all the required information, invoice or purchase 

ticket,  product  box  or  package,  and  product,  must  be  presented  when          

warranty service is required.

2.- If the product stills on the warranty time, the company will repair it free 

of charge.

3.- The  repairing  time  will  not  exceed  30  natural  days,  from  the  day  the 

claim was received.

4.-  Steren  sell  parts,  components,  consumables  and  accessories  to                

customer, as well as warranty service, at any of the addresses mentioned 

later.

THIS WARRANTY IS VOID IN THE NEXT CASES:

If the product has been damaged by an accident, acts of God, mishandling, 

leaky batteries, failure to follow enclosed instructions, improper repair by 

unauthorized personnel, improper safe keeping,   among others.
a)  The  consumer  can  also  claim  the  warranty  service  in  the  purchase             

establishment.

b) If you lose the warranty card, we can reissue it, if you show the invoice 

or purchase ticket.

RETAILER INFORMATION

Name of the retailer
Address
Product
Brand
Part number
Serial number
Date of delivery

In case your product fails or have questions, please contact your 

nearest dealer. If you are in Mexico, please give a call to our Call    

Center.

   

Call Center

01 800 500 9000

Before using your new Electronic insect killer, please read 

this  instruction manual to prevent any damage. Put it away in 

Before using your new Steren 6 Event digital timer, 

please read this instruction manual to prevent any damage. 

Put it away in a safe place for future references.

Before using your new Electronic insect killer, please read this  

instruction manual to prevent any damage. Put it away in a 

 

Product design and specifications are subject to change     

without previous notice.

Product: 6 Event digital timer

Part number: TEM-300

Brand: Steren

• Keep device out of the reach of children.

• Do not plug this timer into another timer switch.

• Do not plug any device performing mechanical movement directly in the timer.

• Do not insert needles or any other metal objects into mains outlet.

• Do not try to open the device, may cause damages and warranty will be void.

• Do not expose to extreme temperatures.

• Do not use or store the equipment near wet places. May cause malfunction or shock

hazard.

• Avoid dropping the unit as this may cause damage.

• Clean with a soft, dry cloth.

The 6 event digital timer has a small size and it is perfect for lamps.

It is very simple to program and includes a rechargeable and internal battery, allowing 

their continuous use even in case of an outage.

The programmed time is in periods of 5 minutes, it has also, a random mode, with 30

minutes periods. It features polarized plug and outlet, LCD screen and it can display 

timeand program.

6  programmable  events,  Backup  battery,  5  minutes  programming  period,  625W           

maximum output.

IMPORTANT

HIGHLIGHTS

CLOCK TIME SETTING

PROGRAMMING OF SWITCHING TIMES (ON/OFF)

CONTROLS

1

2

3

4

5

 If the LCD doesn’t display, plug the unit into a wall receptacle for 1 hour 

to charge the battery.

1.- 

SET 

:  To  set  the  time  and  the                   

program.

2.- 

+  /  -

  :  To  increase  or  decrease  the 

digit  in  setting.  They  are  active  only  in                   

programming process.

3.- 

ON/OFF

 : To change output state to ON/OFF in AUTO or MANUAL mode.

 

AUTO: Execute all programmed events , automatically.

 

MANUAL: The connected device will be powered on/off only if you press the

on/off button.

4.- 

RESET

 : To initialize or reset the unit.

5.- 

OUTLET

: Use to connect your lamps or devices.

1.- Under the normal working conditions press the SET button. The hour digits will 

flash on display.

2.- Using + or – button set the correct hour. The setting time will increase or decrease

continuously if + or – buttons depressed for more than 1 second.

3.- Press the button SET again to set minutes. The minute digits 

will flash on display.

4.- Using + or – buttons set the correct minutes.

5.- Set time will increase or decrease continuously if + or – button 

depressed for more than 1 second.

6-. Press SET button.

7.- Wait few seconds, the clock will be updated.

1.- After  clock  time  setting  has  been  set,  press  the  SET  button 

again to set the firts “ON” program time. The “PROG 1 ON” will 

appear on the LCD display and flash.

2.- Press the + or – buttons to set the ON time of the first program.

Set time will increase or decrease continuously if press and hold +

or – buttons more than 1 second.

3.- When required ON time completed, press the SET button again

to set the program OFF time. The “PROG 1 OFF” will appear on the LCD display and 

flash.

4.- Using + or – buttons set the first program OFF time. The set time will increase or 

decrease continuously if + or – buttons depressed for more than 1 second.

RANDOM ON/OFF SECURITY FEATURE

SPECIFICATIONS

RESET BUTTON

MANUAL OVERRIDE SETTING

Input:  

 

 

125V~ 60Hz 5A max.

Output:    

 

125V~ 60Hz 5A max.

Operational temperature:  

0°C to 40°C

Resistive load:  

 

625Wmax

Tungsten lamp load:    

250Wmax

Press the RESET button. The “0:00” will appear on the LCD display and the unit will 

turn off your system.

You can choose permanent manual ON, Manual OFF.

Press ON/OFF button under ON or OFF mode, the unit will be forced into ON/OFF mode.

Press ON/OFF permanent override. And the LCD will display AUTO.

 Under the manual override mode the random function will be cancelled.

Simultaneously  press  the  SET  and  ON/OFF  buttons  to            

enter the random mode.

A “R” icon will appear on the display. Programmed ON/

OFF time will randomly fluctuate in a range of +/-30min.

Simultaneously  pressing  the  SET  and  ON/OFF  buttons 

again will exit the random mode.

5.- Pr and – buttons simultaneously will cancel the current program setting.

6.- Repeat 1 – 4 steps to set other programs ON/OFF time.

7.- After program setting has been completed, press SET button to run the unit.