background image

27

Ampere

BEFORE TO START

Place the batteries

Remove the cover and insert two “AAA” 

batteries.

Ensure that place the batteries 

with rightly polarity.

If the        symbol appears in the 

screen, you must change the 

batteries

How to connect the test cables

To place the test cables, insert the 

black connector into the COM terminal 

and the red connector in the     

         terminal  

V

Summary of Contents for MUL-107

Page 1: ...1 Mult metro digital de gancho V V0 0 1216v...

Page 2: ...empre retire los cables de prueba antes de reemplazar las bater as o los fusibles Compruebe el estado de los cables de prueba y del medidor mismo antes de operarlo No mida voltajes que excedan 1000V s...

Page 3: ...un juguete mant ngalo fuera del alcance de los ni os Este aparato NO est destinado a ser utilizado por personas con capacidades diferentes a menos que cuenten con la preparaci n y supervisi n adecuad...

Page 4: ...artes V Terminal COM Gancho de medici n Hold retenci n de datos Luz de fondo Perilla de selecci n Pantalla Terminal Pico m ximo Detecci n de voltaje sin contacto Gatillo rea de detecci n de voltaje si...

Page 5: ...alla PMAX kHz Apagado autom tico Bater a baja Medici n m xima de corriente pico pico m ximo de corriente Ampere Kilohertz hertz Ampere Volt kilo ohm mega ohm ohm Corriente directa Corriente alterna Ho...

Page 6: ...AAA Aseg rese colocar las bater as con la polaridad correcta Si el s mbolo aparece en la pantalla significa que la bater a debe ser reemplazada C mo conectar los cables de prueba Para colocar los cabl...

Page 7: ...tados el mult metro arrojar autom ticamente los resultados en el display Voltaje de Corriente Directa Toque con las puntas el circuito V Cuando el valor detectado sea 0 5 V el resultado de la medici n...

Page 8: ...e Alterna y en la parte superior de la pantalla el valor de la frecuencia Si el valor detectado es 1 0V el resultado ser la resistencia y se mostrar en V Resistencia Toque con las puntas el circuito C...

Page 9: ...al mismo tiempo en el rea de medici n esto producir a resulta dos incorrectos Para obtener lecturas precisas coloque el cable en el centro del rea de medici n Cuando el valor detectado sea 0 01A se mo...

Page 10: ...se muestra en la imagen Cuando el valor detectado sea 0 01A se mostrar en la parte superior de la pantalla la corriente de CA 2 Toque con las puntas el circuito Cuando el valor detectado sea 1 0 V el...

Page 11: ...e el cable del circuito como se muestra en la imagen Cuando el valor detectado sea 0 01A se mostrar en la parte superior de la pantalla la corriente de CA 2 Toque con las puntas el circuito Cuando el...

Page 12: ...para abrir el gancho y coloque el cable como se muestra en la imagen No coloque m s de dos l neas al mismo tiempo en el rea de medici n esto producir a resulta dos incorrectos Para obtener lecturas p...

Page 13: ...si tiene energ a el ctrica cable contacto socket etc En caso de detectar presencia de voltaje el dispositivo emitir una se al audible El dise o del circuito el grosor del aislamiento y otras condicion...

Page 14: ...realizar alguna operaci n entrar en estado de hibernaci n y se apagar la pantalla para ahorrar energ a Presione durante algunos segundos para encender la luz de la pantalla Luz de fondo HOLD Despu s d...

Page 15: ...A 0 01 A 400 A 0 1A 400 A 600 A 0 1 A 3 lectura 2 5 lectura Corriente de entrada m nima 0 01A CA Corriente de entrada m xima 600A CA Rango de frecuencia 45 65Hz Pico m ximo de corriente Rango Resoluc...

Page 16: ...5 lectura Voltaje de entrada m nimo 0 5 V CD Voltaje de entrada m ximo 600 V CD Voltaje de Corriente Alterna Rango Resoluci n Precisi n 6 V 0 001 V 60 V 0 01 V 600 V 0 1 V 0 8 lectura Voltaje de entra...

Page 17: ...000 Hz 1Hz 1 0 lectura Rango de medici n 40Hz 1000 Hz Rango de la se al de entrada 0 2 A CA valor efectivo Posici n B Rango Resoluci n Precisi n 60 0 Hz 0 1 Hz 1000 Hz 1Hz 1 0 lectura Rango de medici...

Page 18: ...M 0 001 M 10 M 0 01 M 0 8 lectura Protecci n de sobrecarga 600V CD o CA valor efectivo Prueba de encendido y apagado de l nea Rango Resoluci n Funci n 1 Si la resistencia es menor de 50 el mult metro...

Page 19: ...Rango de Voltaje CA 1 60 V Resistencia 10 M Frecuencia 40 1 000 Hz Rango de Corriente CA 0 001 600 A Temperatura de operaci n 0 40 C Temperatura de almacenamiento 10 a 60 C Consumo 0 1 mW h Consumo e...

Page 20: ...cionadas posteriormente ESTA P LIZA NO SE HAR EFECTIVA EN LOS SIGUIENTES CASOS 1 Cuando el producto ha sido utilizado en condiciones distintas a las normales 2 Cuando el producto no ha sido operado de...

Page 21: ...21...

Page 22: ...22 Hook Clamp Digital Multi meter V V0 0 1216v...

Page 23: ...ck hazard or graves injuries Always remove the test cables before to replace the batteries Check the cables test status and the meter before to use it Don t measuring voltages that exceed 1000V over g...

Page 24: ...ove the batteries This product is NOT a toy keep it away from children This device cannot be used by people with different abilities at less they have preparation and supervision Don t use the meter i...

Page 25: ...25 DESCRIPTION Parts V COM terminal Measuring hook Hold data reten tion Background light Selection knob Screen terminal Max peak Non contact voltage detector Trigger NVC area...

Page 26: ...nectors Symbols in the screen PMAX kHz Auto off Battery low Max measuring of peak max peak of current Ampere Kilohertz hertz Ampere Volt kilo ohm mega ohm ohm Direct current Altern current Hold Auto d...

Page 27: ...batteries Ensure that place the batteries with rightly polarity If the symbol appears in the screen you must change the batteries How to connect the test cables To place the test cables insert the bla...

Page 28: ...ues the meter show automatically the results in the screen Direct current voltage Touch with the tips the circuit V When the detected value is equal to 0 5 V the result of the measure will be Direct C...

Page 29: ...tage and in the high part of the screen appears the frequency value If the detected value is under 1 0V the result will be the resistance and will show in V Resistance When the detected value is highe...

Page 30: ...the same time this will produce wrong measures To obtain accurate measures place the cable into the core of the measuring area When the detected value is higher than 0 01A it will show the current and...

Page 31: ...in the figure When the detected value is higher than 0 01A it will show and in the high part of the screen appears the AC 2 Touch with the tips the circuit When the detected value is equal to 1 0 V th...

Page 32: ...of the circuit as show in the figure When the detected value is higher than 0 01A it will show and in the high part of the screen appears the AC 2 Touch the circuit with the tips When the detected va...

Page 33: ...Press the trigger to open the hook and place as shown below Don t place more than two lines at the same time this will produce wrong measures To obtain accurate measures place the cable into the core...

Page 34: ...r component that you want to check cable contact socket In case to detect voltage presence the device will emit an audible signal The circuit design the insulation thickness and others variables can i...

Page 35: ...HER FUNCTIONS V After 10 minutes of inactivity the meter will shut off to save energy Press for a few seconds to turn on the background light Background light HOLD After to measure press to hold the r...

Page 36: ...6 A 0 001 A 60 A 0 01 A 400 A 0 1A 400 A 600 A 0 1 A 3 reading 2 5 reading Min input current 0 01AAC Max input current 600AAC Frequency range 45 65Hz Max cuerrent peak Range Resolution Accuracy 900 A...

Page 37: ...V 600 V 0 1 V 0 5 reading Min input voltage 0 5 V DC Max input voltage 600 V DC Alternating Current voltage Range Resolution Accuracy 6 V 0 001 V 60 V 0 01 V 600 V 0 1 V 0 8 reading Min input voltage...

Page 38: ...Hz 0 1 Hz 1000 Hz 1Hz 1 0 reading Measuring range 40Hz 1000 Hz Signal input range 0 2 A CA effective value Position B Range Resolution Accuracy 60 0 Hz 0 1 Hz 1000 Hz 1Hz 1 0 lectura Measuring range 4...

Page 39: ...0 1 k 6 M 0 001 M 10 M 0 01 M 0 8 reading Overload protection 600V DC or AC effective value Turn on and line off test Range Resolution Function 1 If the resistance is samaller to 50 the meter will emi...

Page 40: ...V AC Voltage Range 1 60 V Resistance 10 Mohms Frequency 000 Hz 40 1 AC Current Range 0 001 to 600 A Operating Temperature 0 40 C Storage Temperature 10 to 60 C Consumption 0 1mW h Standby Power Consum...

Page 41: ...stomer as well as warranty service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky batterie...

Page 42: ...42...