BR-600
0816A
V1.1
CAUTION
Parts
Controls
Specifications
• This device cannot be used by people with different abilities, unless they have
preparation and supervision.
• This product is NOT a toy; keep it away from children.
• Never leave the clamps without connecting with the charger connected to the mains.
• Do not use this charger in damp or wet environments.
• Before connecting the charger to the battery voltage check it.
1. Harness with alligator connectors
2. Harness with eyelet connectors
3. Charger
Mode button
Power Error
Charge level
Operation mode
Recovery
Reverse polarity
1. Select type of tips that fit
your needs and connect
corresponding harness to
the charger.
3. Press the MODE button to select the
connected battery voltage (6 or 12 V). It
lights up the LED corresponding to the
selected operating mode
8. The charging will begin and the led indicators will light up one by
one according to the charge level. If battery has very low voltage, the
charger will enter in recovery mode and the corresponding LED will
turn on (a moment may pass). When charging is complete and
100%LED will turn on, the charger will turn to floating charge status(If
floating charge status keep more than 72hours, the battery charger
will be closed for safe protected). When the battery is charged, you can
disconnect the charger.
7. Plug the power cord of
the charger into a home
outlet. The power LED
will turn on.
9. To disconnect the charger, remove the power cord from
the outlet, first remove the red lead, and finally, disconnect
the black tip.
Input: 110 a 120 V ~ 50 / 60 Hz 22 W máx.
Output: 12, 6 / 6,3 V - - - 1 A
Consumption: 13 W/h
Stand-by consumption: 1,8 W/h
5. Connect the black tip of
the charger to the negative
terminal of the battery.
6. Connect the red tip of the
charger to the positive terminal
of the battery.
Please note that if you connect the battery before connect the
power outlet, the battery charger mode can not be selected, it
will use the last select mode(6V or 12V), that will be a frequently
operation error.
4. To disconnect the charger,
remove the power cord from the
outlet, first remove the red lead,
and finally, disconnect the black
tip.
Before using your new product, read the following instructions
Ultrasmart acid battery charger
Functioning
MODE
25%
6 V
12 V
RECOND
REVERSE
50%
75%
100%
MODE
25%
6 V
12 V
RECOND
REVERSE
50%
75%
100%
MODE
25%
6 V
12 V
RECOND
REVERSE
50%
75%
100%
!
-
+
-
+
2. Plug the power cord of the
charger into a home outlet. The
power LED will turn on.
MODE
25%
6 V
12 V
RECOND
REVERSE
50%
75%
100%
MODE
25%
6 V
12 V
RECOND
REVERSE
50%
75%
100%
WARRANTY
This Steren product is warranted under normal usage against defects in workmanship and materials to the original purchaser for one year from the date of
purchase.
CONDITIONS
1. This warranty card with all the required information, invoice, product box or package, and product, must be presented when warranty service is required.
2. If the product is in the warranty time, the company will repair it free of charge.
3. The repairing time will not exceed 30 natural days, from the day the claim was received.
4. Steren sell parts, components, consumables and accessories to customer, as well as warranty service, at any of the addresses mentioned later.
THIS WARRANTY IS VOID IN THE NEXT CASES:
If the product has been damaged by an accident, acts of God, mishandling, leaky batteries,
failure to follow enclosed instructions, improper repair by unauthorized personnel, improper
safe keeping, among others.
a) The consumer can also claim the warranty service in the purchase establishment.
b) If you lose the warranty card, we can reissue it, if you show the invoice or purchase ticket.
RETAILER INFORMATION
Name of the retailer _______________________________________________
Address ______________________________________________________
Product _______________________________________________________
Brand ________________________________________________________
01 800 500 9000
In case your product fails or
have questions, please
contact your nearest dealer. If
you are in Mexico, please
call to our Call Center.
Product: Ultrasmart acid battery charger
Part number: BR-600
Brand: Steren
Other operating conditions:
INDICATOR
CONDITION
PROCESS
RECOND
ERROR
Very low voltage level
(Mode charger
Recovery)
Battery damaged or irrecoverable
Leave the charger connected to the battery for a period of 10 to 15 minutes. It will go to
normally charge(it will light the LED charge level 25%).
REVERSE
Reverse polarity
Correctly connect the tips: The black tip on the negative side and red on the positive.
1
2
3
ERROR led constant light, please try below solution:
1. Please check if the 6V/12V Mode select right, if Mode select wrong, please
select right mode as above "Functioning" step.
2. If Mode is selected right, the battery maybe damaged by over discharge. Please
try below steps to recover the battery:
1)Disconnect the tip of the positive terminal.
2) Wait about 10 seconds to reconnect the tip.
After connecting, it should charge normally (it will light the LED charge level 25%)
or in recond mode((it will light the LED RECOND), if it does not work, please try
several times, and if it still does not work, it means the battery is damaged and
irrecoverable. Please replace the battery.
ERROR led flashing light, it means that the battery can not be recovery or the
battery do not have reserve capacity of electricity. Please replace the battery.
C
M
Y
CM
MY
CY
CMY
K