StepperOnline CL57T User Manual Download Page 4

CL57T(V4.0) Closed-Loop Stepper Drive

2

2.3 Mechanical Specifications

(unit: mm [1inch=25.4mm])

Figure 1: Mechanical specifications

2.4 Heat Dissipation

CL57T(V4.0) reliable working temperature should be no more than 40

(109°F)

It is recommended to mount the drive vertically to maximize heat dissipation. Mount a cooling fan nearby if

necessary.

If multiple CL57T(V4.0) drives are installed, it is suggested to keep a minimal 30mm (12 inches) between two of

them.

Summary of Contents for CL57T

Page 1: ...l CL57T V4 0 Closed Loop Stepper Drive Revision 4 0 Record of Revisions Revision Date Description of Release 1 00 Aug 2019 Initial Release 4 00 Oct 2020 Add S1 rotating switch 5 24V selector switch br...

Page 2: ...er Connector 4 3 5 LED Status Lights 4 3 6 Switches 4 4 Power Supply Selection 5 4 1 Power Supply Sharing 5 4 2 Selecting Supply Voltage 5 5 Switch Configurations 6 5 1 S1 Rotating Switch Configuratio...

Page 3: ...oop control setting by SW6 Step Direction or CW CCW pulse type setting by SW7 Position command filter setting by SW8 Over voltage over current protections position following error etc 2 Specifications...

Page 4: ...2 4 Heat Dissipation CL57T V4 0 reliable working temperature should be no more than 40 109 F It is recommended to mount the drive vertically to maximize heat dissipation Mount a cooling fan nearby if...

Page 5: ...l is at least 1 0 s duty cycle is recommended 50 4 Single pulse step direction or double pulse CW CCW is set by DIP Switch SW7 5 DIR signal requires advance PUL signal minimum 2 s in single pulse mode...

Page 6: ...ector PIN Details A Connect to motor A wire A Connect to motor A wire B Connect to motor B wire B Connect to motor B wire 3 4 P4 Power Connector Pin Details GND Connect to power supply ground connecti...

Page 7: ...to use lower supply voltage to decrease noise heating and improve reliability 4 1 Power Supply Sharing Multiple CL57T V4 0 drives can share one power supply to reduce cost if that power supply has en...

Page 8: ...k 100 and 5 composite parameters indicate the rigidity is strong Sometimes if the motor will rotate after stopping it can increase the value of position loop Kp but if the value is too large the motor...

Page 9: ...control SW7 Pulse Mode CW CCW double pulse PUL DIR single pulse SW8 Pulse Filter Time Yes 10ms No 1 5ms CL57T V4 0 has an advanced feature called Pulse Filter Time to make the input pulse from pulse...

Page 10: ...tial or single ended control signals pulse direction and enable in open collector or PNP connection through the P1 connector figure 2 It is recommend to add an EMI line filter between the power supply...

Page 11: ...thus be detected Fault output connection is optional and it can be connected either in sinking or sourcing Figure 7 Sinking output Figure 8 Sourcing output 6 3 Brake Output Connection This drive has a...

Page 12: ...rive incorporates some built in protection features Blink time s Sequence wave of red LED Description Trouble shooting 1 0 2 S 5 S Over current Turn off the power immediately a Check wiring is short c...

Page 13: ...hat they operate independently It is important to document each step in the troubleshooting process You may need this documentation to refer back to at a later date and these details will greatly assi...

Page 14: ...se another motor with higher torque Acceleration is set too high Reduce the acceleration Power supply voltage too low Choose another power supply with large voltage output Excessive motor drive heatin...

Reviews: