To log into the substation:

1.  Click 

Login 

2.  Enter the default User name: 

admin

3.  Enter the default password: 

alphaadmin

The 

Station Information

 page will now be displayed, 

showing the IP substation configuration.

2.2 

Station Main Settings

 

Click 

Station Main

 > 

Main Settings

 to access  

the page for configuring station mode and IP 

parameters.

Registration Settings

 

Enter the IP address of the AlphaCom server/

exchange in which the IP substation is to be a 

subscriber in the 

AlphaCom IP-address

 field.

 

Enter the directory number of the substation in the 

Directory Number

 field. 

 - If a directory number is not entered, the substation 

will register with its MAC address. The MAC address 

is found on the Station Info page and needs to be 

entered into the AlphaPro programming tool.

IP Settings

 

DHCP 

– Use this option if the IP substation shall 

receive IP Settings from a DHCP server.

 

Static IP 

– Select this option if the IP station shall 

use a static IP address. Enter values for:

 

-

IP-address

 

-

Subnet-mask

 

-

Gateway

 

Click 

Save 

followed by 

Apply

 to apply the new 

configuration settings.

Restoring Default Settings

An IP Substation may have to be reset to its original 

factory default settings if, for instance, the password to 

the web server is forgotten. The defaults can be either 

be set to Static IP or Activated DHCP (when there are 

many new IP Substations in an installation).

3.1 

Reset to Default Settings with Static IP

1.  While pressing the call button, power up the 

substation.

2.  When the substation LED starts blinking, release 

the call button 

after exactly 1 blink

.

3.  Let the LED blink for 

exactly 2 more times

, then 

press the button again.

4.  Keep the button pressed until the LED 

blinks fast 2 

times

 indicating a successful reset with static IP.

5.  Release the button and the substation will restart 

with the factory default settings.

Factory default values

 - Station IP address: 

169.254.1.100

 

 - AlphaCom IP address: 

169.254.1.5

 

 - Username: 

admin

 

 - Password: 

alphaadmin

3.2 

Reset to Default Settings with Activated 

DHCP

1.  While pressing the call button, power up the 

substation.

2.  When the substation LED starts blinking, release 

the call button 

after exactly 2 blinks

.

3.  Let the LED blink for 

exactly 4 more times

, then 

press the button again.

4.  Keep the button pressed until the LED 

blinks fast 

4 times

 indicating a successful reset with activated 

DHCP.

5.  Release the button and the substation will restart 

with the factory default settings.

Factory default values

 - Station IP address: 

determined by DHCP server

 

 - AlphaCom IP address: 

169.254.1.5

 

 - Username: 

admin

 

 - Password: 

alphaadmin