background image

Functioning

The  NC88 Module can control the state of two Reed magnetic sensors : the 
output is activated by pressing the START button only if the contacts of two 
sensors are closed. The opening of even only one input contact (S1 and/or S2), 

leads to a safety situation, by putting the safety outputs in open state and by 
preventing the closing even after the re-closing of the contact and the pressure of 

the START button. 

For automatic start, see connection diagram. 

Input channels work on opposite potentials (S11

-

; S21

+

).

It's available an input (X1-X2) for feedback with contactors or external relays (see 
Ka and Kb on the connection diagram).

The control unit has a dedicated circuit to guarantee  the its correct functionality 

in case of  short voltage dips

The safety is ensured by using guided contacts, by the redundance and by the 

interconnection schematic of the contacts.

The responsibility to choose the adequate components for safety applications, for 
example guided contacts safety relays, falls to the user.   

Assembly

Installation must be performed by authorized personnel only.

The NC88 control unit must be assembled in a suitable operating area (switch 
cabinet, protective housing).
The unit is installed by clipping it to a standard 35 mm top-hat rail.

         Safety Precautions
The manufacturer of a machine or installation is responsible for correct and 
safe overall function.
Auxiliary output Y1/Y2 and Y2Y3 are optoinsulated and gives informations 
about the state of the device; it must not be used as a safety output.

NC88 is not proper for the operation in presence of ionizing and not ionizing 
radiations (rays X, microwaves, laser, ultraviolet rays)   
(CEI EN 60204-1:2006, §4.4.7).

Operating instructions for safety control unit mod. NC8 8

STEM S.r.l.  via della Meccanica, 2  I-27010  Cura Carpignano  Pavia Italia  Tel. +39 0382 583011  Fax +39 0382 583058    www.stemsrl.it     [email protected]

!

Description

The NC88 safety relay is created for use in safety circuit intended by

EN 81-20:2014, EN 81-50:2014

This module is based upon the use of guided-contact safety relays.

!

Electrical Connection
Electrical connection must be performed by authorized personnel only.

All the electrical inputs must either be isolated from the mains supply by a 
separate coils safety transformer in accordance with EN IEC 61558-2-6
with limited output voltage in the event of a defect or by another equivalent 

movable mechanism.

The outputs of the relays have a maximum current of 3 A; the supply 
connectedto the outputs must be protected from overcurrents by devices 
adequate to the loads that have to be protected.  
All the output contacts must have an adequate protective circuit for capacitive 
and inductive loads.

If a common power supply is used, all the inductive and capacitive loads (e.g. 
relay contactors) connected to the power supply must be connected to 

appropriate interference suppressors.

Service and Inspection
The correct functioning of the NC88 safety unit must be controlled by the 
operator and/or by the control circuit of the elevator in which it is used 
periodically, by checking:
- Correct switching function of each sensor by checking:
    a) that the opening of the single sensor will cause the opening of the safety 
outputs (13-14 / 23-24)
    b) that  the closure of the same sensor  will cause the closing of the safety 
outputs (13-14 / 23-24) as a result of a startup command
- secure mounting of components
- correct connection fixing.
The monitoring function of the unit is done at every switching cycle. If the 
elevator is in a door zone and following the eventual start command, the 
safety device does not activate its safety outputs,  do not turn off and turn on 
the device, then proceed to the checking of the possible sensor fault and 
perform the above tests in point a) and b).

In the event of damage or wear and tear, the damaged system component 
must be replaced.

Liability coverage is void under the following circumstances:
- if instructions are not followed
- non-compliance with safety regulations
- installation and electrical connection not performed by authorized personnel
- non-implementation of functional checks.

Setup

If the control unit does not appear to function when operating voltage is 

applied (yellow LED does not light up), the unit must be returned unopened to 
the manufacturer.
Check whether the safety outputs are being switched (see LED display) by 
activating the two inputs S1, S2 and START.

Connections

Y2

Signal  outputs 

Power supply

24 V ac/dc

A1 A2 Y1

Ka

Start

 button

(reset)

Feedback 

control loop

N

M

3

K1

23

X1

Y3 Y4

K1

X2 13 14

L3

L1L2

24

Inputs(Reed sensors)

S22

S21

K2

K3

K2

S11S12

K3

K3

Safety 

outputs

Kb

S2

S1

L

+      -     

Automatic start connections

1) Automatic start with the sync time between inputs infinite 

  (ONLY for use in the lift industry - EN81-20: 2014).

Reed switch sensors ID, IS and IZ.
In this configuration the inputs synchronization time among the closing of IZ 

and one between IS and ID, it is endless, but a correct closing sequence has 
to be respected: the first contact to be closed is IZ, then IS or ID.
This configuration cannot be used with Hall effect sensors.

S12

S11

S22

S21

X1 X2

GND

+

+

NOT CONNECTED

IZ

IS

ID

Feedback loop of the 

external contactor 

(short-circuit if not used) 

MD

N.O

.

N.O

.

MZ

N.O

.

MS

ID

IZ

IS

2) Short-circuit of S33 and S34; in this case there will be a 
synchronism time between inputs of 600 ms.

X1 X2

S

u

b

je

c

to

 t

e

c

h

n

ic

a

m

o

d

if

ic

a

ti

o

n

s

 w

it

h

o

u

n

o

ti

c

e

n

o

 l

ia

b

ili

ty

 w

ill

 b

e

 a

s

s

u

m

e

d

 f

o

a

n

y

 d

e

ta

il.

  

  

  

©

 S

T

E

M

 S

.r

.l

 1

S

M

A

 N

C

8

8

 0

0

0

0

 r

e

v

.4

 1

9

/0

2

/2

0

1

8

Reviews: