background image

S

u

b

je

c

to

 t

e

c

h

n

ic

a

m

o

d

if

ic

a

ti

o

n

s

 w

it

h

o

u

n

o

ti

c

e

n

o

 l

ia

b

ili

ty

 w

ill

 b

e

 a

s

s

u

m

e

d

 f

o

a

n

y

 d

e

ta

il.

  

  

  

©

 S

T

E

M

 S

.r

.l

 1

S

M

A

 N

C

8

8

 0

0

0

0

 r

e

v

.4

 1

9

/0

2

/2

0

1

8

Dimensions

S21

A1

S11

S22

S12

X2

X1

A2

Y1

13

23

Y4

Y3

Y2

START

PWR

NC88

OUT

STEM

S2

S1

 I

n

p

u

ts 

L

2

L

1

L

3

S

ig

n

a

o

u

tp

u

ts

S

u

p

p

ly 

2

4

 V

 a

c/

d

c

N

F

e

e

d

b

a

ck

c

o

n

tr

o

lo

o

p

K

a

M

K

b

S

2

2

Y

2

Made in Italy

Y

1

A

2

A

1

S

2

1

K

3

2

3

K

1

1

4

1

3

X

2

Y

4

Y

3

X

1

K

1

2

4

S

a

fe

ty 

o

u

tp

u

ts

L

K

2

S

1

2

S

1

1

K

2

S

u

p

p

ly:

 2

4

 V

 A

C

/D

C

 +

1

5

%

-1

0

%

 (

A

C

 5

0

 ÷

 6

0

 H

z)

S

a

fe

ty 

o

u

tp

u

ts 

(1

3

-1

4

2

3

-2

4

):

  

3

 A

2

5

0

 V

 A

C

ty

p

e

 

N

C

8

8

S

Ü

D

S

af

et

y

te

st

ed

P

r o

du

ct

io

n

m

on

it

or

ed

0

9

4

8

Operating instructions for safety control unit mod. NC8 8

STEM S.r.l.  via della Meccanica, 2  I-27010  Cura Carpignano  Pavia Italia  Tel. +39 0382 583011  Fax +39 0382 583058    www.stemsrl.it     [email protected]

3

M

14

24

S

T

A

R

T

(r

e

s

e

t)

S1, S2

START

Power

S1, S2

START

LED DISPLAYS

Inputs S1, S2, START: CLOSE

Inputs S1, S2, START: OPEN

Outputs 13/14, 23/24 and Y1/Y2: CLOSE

Outputs 13/14, 23/24 and Y1/Y2: OPEN

Function

Supply Voltage

on

off

on

green

green

-

OUT

off

State

on

Color

(ON)

-

green

OUT

LED

PA 6.6

OUT=off: 50    OUT=on: 100

EN 81-50:2014

EN12015, EN12016, EN 61000-6-2, EN 61000-6-3, EN 55011:1999 

3 (MAX)

3,3

60 (MAX)

55 (MAX)

750

10

2,5 x 10   (250 Vac, 3 A cos

φ

=1) 

5

7

250

1

24 +15%, - 10% (AC 50 ÷ 60 Hz)

115 x 105 x 22,5 / 180 

IP20

3

A

W

mA

Vdc

VA

V AC

V ac/dc

Hz

mA

ms

ms

mm / g

AC-15: 0,9A, 250V

TÜV  n° EDES 007

kPa

°C

kPa

°C

EN 81-20:2014, EN 81-50:2014

cycles

cycles

TECHNICAL DATA

Parameter

Value

Units

Pressure: 86 ... 106 

Relative humidity: 5% ... 95% 

Temperature: -25 ... +70

Pressure: 86 ... 106 

Relative humidity: 4% ... 100% 

Housing conditions

Operating conditions

Temperature: 0 ... +55

Housing Material

Dimensions / Weight

DIN standard 35 mm guide

Connection type

Supply voltage

Plug-in screw terminals

Degree of contamination

Degree of protection (IEC 60529)

Assembly

750 mA  resettable PTC

Typical 120, max 160

Current consuption

Internal fuse on the supply

Max. switching frequency

Input synch. time ts (automatic start -2-)

 

Output response time (t1)

13-14 e 23-24  (normally open)

Y1-Y2, Y3-Y4  (collector-emitter optoinsulated)

Auxiliary outputs terminals

Safety Output switching voltage

Safety output switching current

Safety output switching power

Safety outputs terminals

Auxiliary Output voltage

Auxiliary output current

Auxiliary output power

Usage category

Vibration resistance

Mechanical operation life

EMC compliance

Electrical operation life

Approvals

In accordance with

OFF state response time (t2)

15

ms

13-14 / 23-24

S1

S2

Timing diagram for manual start

START

S1

S2

13-14 / 23-24

Timing diagram automatic start - 2 -
(X1-X2 bridged)

t1

t2

IZ

IS o ID

13-14 / 23-24

t1

t2

ts

ts

ts

ts

Timing diagram automatic start  - 1 -

600

ST

EM

 S

.r.

l.

Via

 d

ell

a M

ecca

nica

, 2

I-2

70

10

 C

ura

 C

arp

ig

na

no

 P

V

IT

AL

IA

ww

w.s

te

msr

l.it

Overvoltage Category

13-14

23-24

S1

S2

Voltage dip

Voltage 
supply

Voltage 
dip

t= 200ms

Reviews: