PROBLEM

DEFECTIVE PART OR PART TO CHECK

The dimmer is hot.

•   Under normal operating conditions, the dimmer housing can reach nearly 

40° C at maximum load. This is normal and will not adversely affect the 

operation of the dimmer.

Heating is always on even if the 

display reads ---.

•   Check if the dimmer is properly connected. Refer to the installation 

section.

Heating does not work even 

though the dimmer indicates 

it is on.

•   Check if the dimmer is properly connected. Refer to the installation 

section.

The display does not come on.

•   Check if the dimmer is properly connected. Refer to the installation 

section. Check  the power supply at the electrical panel.

The display is dim when the 

heating is on.

•   The load is lower than the minimum load. Install a heating unit that is 

within the load limits of the dimmer.

Weak luminosity of the display.

• 

 Possibility of a bad contact. Check the dimmer connections. Refer to the 

installation section.

N.B.  If  you  are  unable  to  solve  the  problem  after  having  verified  these  points,  please  communicate  with  our 

customer service. Consult our website for the phone numbers.

TROUBLESHOOTING

Summary of Contents for SIRHC402-1

Page 1: ...2 1 DIMMER WITHTIMER FOR INFRARED RADIATOR USER S GUIDE For further information or to consult this guide online please visit our website at www stelpro com S Y S T M E Q U A L I T C ERTIFI REGISTERED...

Page 2: ...st be adhered to in order to avoid personal injuries or property damages serious injuries and potentially fatal electric shocks All electric connections must be made by a qualified electrician accordi...

Page 3: ...s using the solderless connectors Refer to the following diagram For connections with aluminum wires you must use CO ALR connectors Please note that the dimmer wires have no polarity which means that...

Page 4: ...RHC402 1_0720 6 Replace the front part of the dimmer on the mounting base and tighten the screw at the bottom of the unit 7 Turn on the power 8 Set the dimmer to the desired setting see the following...

Page 5: ...5 INSSIRHC402 1_0720 Mode in use indicator Power mode Adjustment of power mode Adjustment of timer mode Timer mode OPERATION...

Page 6: ...ation of this operation will not exceed 14 seconds During this operation the Power mode and Timer mode icons will be displayed either as a fixed display or as blinking icons Adjusting the power and th...

Page 7: ...e timer Setting the power to off while the timer is active resets the timer Once the timer has been reset the Power mode with inactive timer will be activated Timer mode In Timer mode the timer symbol...

Page 8: ...time on the timer has run out The three figures at the top of the digital screen will display Saving the parameters The dimmer will not save any parameters Therefore in the event of a power failure th...

Page 9: ...perly connected Refer to the installation section The display does not come on Check if the dimmer is properly connected Refer to the installation section Check the power supply at the electrical pane...

Page 10: ...a 3 year warranty If at any time during this period the unit becomes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service department with...

Reviews: