PREvENTIvE MAINTENANCE
Do not try to repair your furnace yourself. Call a qualified technician.
However, before calling a technician, check the following points.
1. Make sure fuses or circuit breakers are activated.
2. Adjust the temperature set point of the thermostat above the ambient
temperature. If heating does not start, cut off the power supply and call
a technician.
N.B. When calling a technician for maintenance or to order a
replacement part, specify the model of your furnace as well as
its serial number.
AIR FIlTER
excessive dust or dirt accumulation can block the airflow, forcing the
unit to work harder to maintain the desired temperature. Therefore, it
uses more energy and increases heating costs.
Since the air filter supplied is disposable, you should replace it two
to four times a year, according to the model used and the installation
area. Dirtier areas can require more than four filter changes.
To replace a dirty filter, open the access door to the filter, remove the old
filter and insert the new one inside the rack. make sure the new filter has
the same technical specifications and size as the previous one.
N.B. Never operate the unit without a filter in place.
every time a filter is changed, you should check the following points.
- Excessive accumulation of dirt or dust on furnace components.
- Damaged components or surfaces.
- Presence of water inside or outside the furnace.
If you encounter any of these problems, do not operate the furnace.
Call a qualified technician.
blOwER
The blower motor is sealed and permanently lubricated, so it is not
necessary to lubricate it.
even if you change the filter frequently, the blower’s blades and motors
will become dust laden after a few months. The entire blower assembly
should be inspected annually. If needed, vacuum out the dust. If you
cannot clean the blower without removing it from the furnace, this
service must be performed by a qualified technician.
REf. #
PaRT #
DEscRIPTIoN
1
CAP-002
CAPACITOr 20 UF FOr 1 HP AT 240 V wITH SUPPOrT
1
CAP-010
CAPACITOr 6 UF FOr 1/3 HP AT 240 V wITH SUPPOrT
2
mOSeF1023
rePlACemeNT KIT SeF mOTOr/BlOwer 10-23 Kw
2
mOSeF2730
rePlACemeNT KIT SeF mOTOr/BlOwer 27-30 Kw
2
mOSeF1023wB
rePlACemeNT KIT SeF mOTOr ONly 10-23 Kw
2
mOSeF2730wB
rePlACemeNT KIT SeF mOTOr ONly 27-30 Kw
3
BlO-004
SQUIrrel CAge & BlOwer 10-8 FOr 10 TO 23 Kw.
3
BlO-005
SQUIrrel CAge & BlOwer 12-11 FOr 27 & 30 Kw.
4
BreA-001
BreAKer 30 AmPS 120/240 VOlTS 2-POle
4
BreA-002
BreAKer 40 AmPS 120/240 VOlTS 2-POle
4
BreA-003
BreAKer 50 AmPS 120/240 VOlTS 2-POle
5
TRF200040D
TrANSFO 240-208/24/50VA (SeC.10.5 &13)
6
REL-004
relAy 24 V, FOrm X, 18 A reS.
6
REL-005
relAy 240 V, FOrm X, 18 A reS.
6
REL-003
relAy 24 V, FOrm C, 20 A NO, 10 A NC
7
SEQ-005
DOUBle SeQUeNCer 24 V, H1-20 C40-90, H30-90 C1-30
7
SEQ-003
SINgle SeQUeNCer 24 V, H30-90 C1-30
7
SeQ.-007
DOUBle SeQUeNCer 24 V, H40-100 C1-30, H25-60
C25-45
8
PrOT-010
THermAl PrOTeCTION l-160-40 - 10Kw TO 23 Kw
8
PrOT-019
THermAl PrOTeCTION l-140-40 - 27Kw & 30 Kw
9
SWI-004
SPDT SwITCH wITHOUT mArKINgS 16 A, 250 V, 3/4 HP,
250 V, T85
10
PL-001
greeN PIlOT lIgHT 28 V, 04 A
10
PL-002
greeN PIlOT lIgHT 250 V, 1/3 w
11
ELF-SEF0521
elemeNT ASSemBly 5Kw
11
ELF-SEF0421
elemeNT ASSemBly 4Kw
11
ELF-SEF0321
elemeNT ASSemBly 3.5 Kw
11
ELF-SEF0221
elemeNT ASSemBly 2 X 2.5 Kw
A
DETAIL A
B
DETAIL B
C
DETAIL C
5
6
6
6
7
E
DETAIL E
9
10
1
2
3
4
8
11
D
DETAIL D
replacement component list