PREvENTIvE MAINTENANCE

Do not try to repair your furnace yourself. Call a qualified technician. 

However, before calling a technician, check the following points.
1. Make sure fuses or circuit breakers are activated.
2. Adjust the temperature set point of the thermostat above the ambient 

temperature. If heating does not start, cut off the power supply and call 

a technician.

N.B. When calling a technician for maintenance or to order a 

replacement part, specify the model of your furnace as well as 

its serial number.

AIR FIlTER

excessive dust or dirt accumulation can block the airflow, forcing the 

unit to work harder to maintain the desired temperature. Therefore, it 

uses more energy and increases heating costs.
Since the air filter supplied is disposable, you should replace it two 

to four times a year, according to the model used and the installation 

area. Dirtier areas can require more than four filter changes.

To replace a dirty filter, open the access door to the filter, remove the old 

filter and insert the new one inside the rack. make sure the new filter has 

the same technical specifications and size as the previous one.

N.B. Never operate the unit without a filter in place.

every time a filter is changed, you should check the following points.

-  Excessive accumulation of dirt or dust on furnace components.

-  Damaged components or surfaces.

-  Presence of water inside or outside the furnace.
If you encounter any of these problems, do not operate the furnace. 

Call a qualified technician.

blOwER

The blower motor is sealed and permanently lubricated, so it is not 

necessary to lubricate it.
even if you change the filter frequently, the blower’s blades and motors 

will become dust laden after a few months. The entire blower assembly 

should be inspected annually. If needed, vacuum out the dust. If you 

cannot clean the blower without removing it from the furnace, this 

service must be performed by a qualified technician.

REf.  #  

PaRT #

DEscRIPTIoN

1

CAP-002

CAPACITOr 20 UF FOr 1 HP AT 240 V wITH SUPPOrT

1

CAP-010

CAPACITOr 6 UF FOr 1/3 HP AT 240 V wITH SUPPOrT

2

mOSeF1023

rePlACemeNT KIT SeF mOTOr/BlOwer 10-23 Kw

2

mOSeF2730

rePlACemeNT KIT SeF mOTOr/BlOwer 27-30 Kw

2

mOSeF1023wB

rePlACemeNT KIT SeF mOTOr ONly 10-23 Kw

2

mOSeF2730wB

rePlACemeNT KIT SeF mOTOr ONly 27-30 Kw

3

BlO-004

SQUIrrel CAge & BlOwer 10-8 FOr 10 TO 23 Kw.

3

BlO-005

SQUIrrel CAge & BlOwer 12-11 FOr 27 & 30 Kw.

4

BreA-001

BreAKer 30 AmPS 120/240 VOlTS 2-POle

4

BreA-002

BreAKer 40 AmPS 120/240 VOlTS 2-POle

4

BreA-003

BreAKer 50 AmPS 120/240 VOlTS 2-POle

5

TRF200040D

TrANSFO 240-208/24/50VA (SeC.10.5 &13)

6

REL-004

relAy 24 V, FOrm X, 18 A reS.

6

REL-005

relAy 240 V, FOrm X, 18 A reS.

6

REL-003

relAy 24 V, FOrm C, 20 A NO, 10 A NC

7

SEQ-005

DOUBle SeQUeNCer 24 V, H1-20 C40-90, H30-90 C1-30

7

SEQ-003

SINgle SeQUeNCer 24 V, H30-90 C1-30

7

SeQ.-007

DOUBle SeQUeNCer 24 V, H40-100 C1-30, H25-60 

C25-45

8

PrOT-010

THermAl PrOTeCTION l-160-40 - 10Kw TO 23 Kw

8

PrOT-019

THermAl PrOTeCTION l-140-40 - 27Kw & 30 Kw

9

SWI-004

SPDT SwITCH wITHOUT mArKINgS 16 A, 250 V, 3/4 HP, 

250 V, T85

10

PL-001

greeN PIlOT lIgHT 28 V, 04 A

10

PL-002

greeN PIlOT lIgHT 250 V, 1/3 w

11

ELF-SEF0521

elemeNT ASSemBly 5Kw

11

ELF-SEF0421

elemeNT ASSemBly 4Kw

11

ELF-SEF0321

elemeNT ASSemBly 3.5 Kw

11

ELF-SEF0221

elemeNT ASSemBly 2 X 2.5 Kw

A

DETAIL A

B

DETAIL B

C

DETAIL C

5

6

6

6

7

E

DETAIL E

9

10

1

2

3

4

8

11

D

DETAIL D

replacement component list