This product is designed and manufactured to prevent water pipes from freezing. Improper 

installation, use or maintenance of this electrical heating cable can cause fire, electric shock or 

freezing of pipe.

Heating cables must be installed in compliance with all national, state, provincial and local 

codes. Check with your local electrical inspector for specific details.

WARNING: Never install the heating cable on a plastic pipe unless the pipe 
is continually filled with water. Use plastic (including PEX tubing) piping 
material suitable for residential water applications. Never spiral heating 
 cable on the pipe. Install the heating cable straight along the pipe. To 
 ensure even heat distribution, we strongly recommend wrapping plastic 
pipes with aluminum adhesive foil tape before applying the heating cable.

WARNING: Use on water pipes only and comply with these important 
 instructions. The minimum pipe length should be 3 ft (90 cm).

WARNING: Strictly adhere to the following guidelines. Failure to do so 
could cause the heating cable to overheat and result in a serious fire 
hazard or electrical shock.

1. 

Never

 plug in the heating cable while it is coiled.

2. 

Never

 install so that external heat sources might overheat installation. Do not use the 

 heating cable on pipes heated above 65°C (150°F) such as steam lines.

3. 

Never

 alter this heating cable in any way. If made shorter, it will overheat. Any attempt to 

physically alter the heating cable will void the warranty. Once cut, the heating cable cannot 

be repaired.

4.  The temperature sensor and the entire heating cable must be in contact with the pipe.
5. 

Never

 use metal binding to secure heating cable to the pipe.

6.  Do not install the same cable on more than one pipe. Doing so could cause the heating 

cable to overheat and may result in fire or electrical shock.

7. 

Never

 allow the heating cable to touch, cross or overlap itself at any point. Doing so will 

cause the heating cable to overheat and could result in fire or electrical shock.

8. 

Never

 install heating cable in walls, floors or ceilings.

9.  Combustible material must not be within ½ in. (13 mm) of the completed installation.

Summary of Contents for SCPT Series

Page 1: ...I T C ERTIFI REGISTERED Q U A L I T Y S Y S T E M WWW STELPRO COM 1 844 STELPRO SCPT CONSTANT WATTAGE PIPE FREEZE PROTECTION HEATING CABLE THANK YOU FOR YOUR PURCHASE NEED ASSISTANCE CONTACT STELPRO...

Page 2: ...NG Strictly adhere to the following guidelines Failure to do so could cause the heating cable to overheat and result in a serious fire hazard or electrical shock 1 Never plug in the heating cable whil...

Page 3: ...ustration below The maximum overrun in the middle of the pipe should not exceed 3 ft 90 cm Do not install on pipes shorter than 3 ft 90 cm long 2 CABLE INSTALLATION To protect standard length pipes wi...

Page 4: ...N TOOLS REQUIRED Marking pencil Scissors Measuring tape File Note Accessories are sold separately ACCESSORIES REQUIRED Fibreglass or aluminum adhesive foil tape in 13 mm thick fibreglass or equivalent...

Page 5: ...ever install the SCPT heating cable when it is colder than this temperature If the heating cable is stiff due to cold first uncoil it and then plug it into a 120 V power outlet until it is warm and pl...

Page 6: ...tion that s more than in 13 mm thick Over insulation could cause the heating cable to overheat and result in a serious fire hazard or electrical shock WARNING In compliance with all national state pro...

Page 7: ...ny physical damage This cable does not contain any serviceable parts The heating cable may remain on the pipe all year round but we recommend always turning off or disconnecting the power at the end o...

Page 8: ...elating thereto Without limiting the generality of the foregoing STELPRO expressly disclaims any liability for property or personal injury damages penalties special or punitive damages damages for los...

Reviews: