12
Snow sensor
sensitivity
Number of
snow sensors
Test
conditions
mode
Save changes
and return to
normal display
Snow detection
threshold
Snow sensor
sensitivity
Number of
snow sensors
Test
conditions
mode
Save changes
and return to
normal display
Snow detection
threshold
Snow sensor
sensitivity
Number of
snow sensors
Test
conditions
mode
Save changes
and return to
normal display
Snow detection
threshold
Snow sensor
sensitivity
Number of
snow sensors
Test
conditions
mode
Save changes
and return to
normal display
Snow detection
threshold
1.
Press the [SELECT] and [+]
buttons simultaneously. “P88”
and the snow sensor threshold
will appear on the display.
2.
Use the [+] and [-] buttons to
adjust the threshold. Range:
00...60 minutes. Default:
1 minute. If the threshold is not
reached, snow detection will
not affect the logic for turning the heaters ON
or OFF. During countdown to threshold time,
the snowflake icon will flash.
1.
Press the [SELECT] and [+]
buttons simultaneously. “P09”
and the number of snow
sensors connected will appear
on the display.
2.
Use the [+] and [-] buttons
to select 1, 2, 3 or 4 snow
sensors. Default: 1
Turn ON test conditions to check the functionality of the system regardless of sensor parameters (i.e.
during the summer). In test conditions, the ambient temperature is always -5°C/23°F.
Note :
To trigger the system and activate the heaters, use some water to wet the circuit on top of the
snow sensor.
1.
Press the [SELECT] and [+] buttons simultaneously. “P10” will appear on the display. The hours will
blink.
2.
Use the [+] button to enter test/commissioning mode – “Test” will appear on the display.
3.
Use the [+] button to manually exit test/commissioning mode – “Test” will disappear from display.
Note :
If the technician did not manually exit test/commissioning mode, the unit will automatically
return to normal mode after 5 hours.
P88
SNOW DETECTION THRESHOLD
P09
NUMBER OF SNOW
SENSORS CONNECTED
P10
TEST CONDITIONS MODE / TECHNICIAN COMMISSIONING MODE
Snow detection
threshold
Number of snow
sensors
Test conditions
mode
IMPORTANT: Make sure the unit is turned
OFF (the word “OFF” should appear on
the display).
1.
Move DIP switch S1 to ON position.
2.
Press and hold the [ON] button for 10 seconds.
The thermostat will beep.
3.
Move DIP switch S1 back to OFF position.
RESTORE DEFAULT VALUES
SAVE CHANGES AND RETURN
TO NORMAL DISPLAY
Move DIP switch S1 back to
OFF position.
Save changes and
return to normal display