INS_CUST UL REV E
Page 28
D. IN-LINE POWERVENT PREPARATIONS
*,1/,1(32:(59(1735(3$5$7,21656,)
)LJXUH*6LOKRXHWWH&LUFOHRQ,QWDNH
SILHOUETTE CIRCLE
SILHOUETTE CIRCLE
)LJXUH*7HQ,QFK%9HQW&ROODU
)LJXUH*,Q/LQH3RZHUYHQW56,)
INTAKE SIDE
INTAKE SIDE
Perform the following steps when installing the RSIF180 on 6', 7'
& 8' models.
1. Attach the provided 10 inch B-Vent collar to the intake side
of the powervent. The intake side is located opposite the fan
motor as shown in Figure 8G.1. The 10 inch B-Vent collar is
packaged separately from the powervent. See Figure 8G.2.
2. Note the silhouette circle printed on the intake side of the
powervent. The pre-drilled screw holes within the circle will
be matched with the holes on the intake collar of the base
plate. See Figure 8G.3.
3. Place the intake collar base plate onto the silhouette,
matching up the holes as shown in Figure 8G.4. Fasten the
EDVHSODWHWRWKHVLOKRXHWWHXVLQJ¿YHVHOIWDSSLQJVFUHZV
4. Add the rope gasket included with the kit to the outlet side of
the inline powervent.
5. An adapter to increase from eight inch pipe to ten inch pipe
is required on the outlet side of the in-line powervent. The
adapter is included in the RSIF180 kit. See Figure 8G.5.
Connect the adapter directly to the eight inch outlet collar of
the in-line powervent. Connect the ten inch exhaust B-Vent
to the collar and continue the vent run.
OUTLET
OUTLET
FAN MOTOR
FAN MOTOR
)LJXUH*%DVH3ODWH)DVWHQHGWR,QWDNH
6&5(:6727$/
6&5(:6727$/
)LJXUH*
Summary of Contents for 3-4S-2-GL