![Stellar Hearth Products 3BY-24GL Installation And Operating Manual Download Page 37](http://html1.mh-extra.com/html/stellar-hearth-products/3by-24gl/3by-24gl_installation-and-operating-manual_1371591037.webp)
Page 37
16400-7802 GBY REV G
10 - ELECTRIC
To light the fireplace: Activate the switch.
The fireplace has a pre and post timer, set at the factory for 30 seconds.
The powervent will start after the switch is activated.
The flame will not turn on for 30-60 seconds after switch is activated
and the powervent will run for 30 seconds after it has been shut off.
*
# FUNCTION
1 120 VAC SW2 LIGHTS
2 120VAC SW2 LIGHTS
3 120VAC SW1 MAIN FLAME
4 120 VAC SW1 MAIN FLAME
5 120 VAC SUPPLY
6 NEUTRAL
7 NEUTRAL POWERVENT
8 120VAC POWERVENT
9 24VAC FLUE DAMPER POWER
10 24VAC FLUE DAMPER NEUTRAL
11 SW3 FLUE DAMPER PROVE
12 SW3 DAMPER PROVE
13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
NOTES:
120 VOLT LOOP
120 VOLT LOOP
120 VOLT LOOP
120 VOLT LOOP
CONNECT TO CONSTANT POWER SOURCE
CONNECT TO CONSTANT POWER SOURCE
DO NOT SHARE NEUTRAL
FROM SPEED CONTROL
OPTIONAL
OPTIONAL
OPTIONAL. USE PURPLE AND WHITE, NOT RED
OPTIONAL. USE PURPLE AND WHITE, NOT RED
FOUR SIDED ONLY
FOUR SIDED ONLY
# FUNCTION
1 120 VAC SW2 LIGHTS
2 120VAC SW2 LIGHTS
3 120VAC SW1 MAIN FLAME
4 120 VAC SW1 MAIN FLAME
5 120 VAC SUPPLY
6 NEUTRAL
7 NEUTRAL POWERVENT
8 120VAC POWERVENT
9 24VAC FLUE DAMPER POWER
10 24VAC FLUE DAMPER NEUTRAL
11 SW3 FLUE DAMPER PROVE
12 SW3 DAMPER PROVE
13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
Powervent
Voltage Chart
Supply
Voltage Chart (N/L1)
Figure 10A
A. ELECTRIC - AT INSTALL
Summary of Contents for 3BY-24GL
Page 2: ...INS_CUST UL REV E Page 2...
Page 35: ...Page 35 16400 7802 GBY REV G...
Page 51: ...Page 51 16400 7802 GBY REV G...
Page 52: ...INS_CUST UL REV E Page 52...