background image

 

 

6913400050

 

 

 

9

 

protective glass according to  standards (degree of 
protection DIN 10). 
-  warn  people  in  the  vicinity  not  to  look  directly  at 
the arc. 

 
PREVENTION OF FIRE 

Welding produces splashes of molten metal. 
Take the following precautions to prevent fire: 
-  ensure  that  there  is  a  fire  extinguisher  in  the 
welding area. 
-  remove  all  inflammable  material  from  the 
immediate vicinity of the welding area. 
-  cool  the  welded  material  or  let  it  cool  before 
touching it or putting it in contact with combustible 
material 
- never  use  the  machine for  welding  containers  of 
potentially  inflammable  material. These  containers 
must  be  completely  cleaned  before  they  are 
welded. 
-  ventilate  the  potentially  inflammable  area  before 
using the machine. 
-  do  not  use  the  machine  in  atmospheres 
containing  high  concentrations  of  powders, 
inflammable gases or combustible vapours. 

 

GENERAL 
CHARACTERISTICS 

This  new  series  of  welding  machines  with 
electronic 

regulation 

controlled 

by 

microprocessor  ,allows  you  to  achieve  excellent 
welding 

quality, 

thanks 

to 

the 

advanced 

technologies  applied.  The  microprocessor  circuit 
controls  and  optimises  the  transfer  of  the  arc 
irrespective  of  the  load  variation  and  of  the 
impedance of the welding cables. 
The  controls  on  the  front  panel  allow  easy 
programming of the welding sequences depending 
on the operating requirements. 
The  inverter  technology  used  has  allowed  the 
following to be obtained: 
- machines with extremely low weight and compact 
dimensions; 
- reduced energy consumption ; 
- excellent dynamic response; 
- very high power factor and yields; 
- better welding characteristics; 
- viewing of the data and of the set functions on the 
display. 
 
The  electronic  components  are  enclosed  in  a 
sturdy  structure  that  is  easy  to  carry  and  cooled 
with forced air by fans with low noise production. 

 

N.B.  This  welding  machine    is  not  suitable  for 
thawing pipes. 
 
 
 
 
 

DELIVERY OF THE MATERIAL 

The package contains: 
- N. 1 welding machine  
- N. 1 instruction manual 
Check that all the material listed above is included 
in the package. Inform your distributor if anything is 
missing. Check that all the material listed above is 
included  in  the  package.  Inform  your  distributor  if 
anything  is  missing.  Check  that  the  machine  has 
not been damaged in transport. If you see any sign 
of  damage,  consult  the  COMPLAINTS  section  for 
instructions. Before working with the machine, read 
the SAFETY and USE section of this manual. 
 

COMPLAINTS 

Complaints for damage during transport

: If your 

equipment  is  damaged  during  transit  you  must 
present a claim to the carrier. 

Complaints  for  faulty  goods

:  All  the  equipment 

shipped  by  STEL  is  subjected  to  strict  quality 
control. However, if your equipment does not work 
properly, consult your authorised dealer. 

 

TECHNICAL DATA 

 

 

 
A) IDENTIFICATION 
Name, address of the manufacturer 
Type of welding machine 
Identification with reference to serial number 
Symbol of the type of welding machine 
Reference to the construction standards 
 
B) WELDING OUTPUT 
Symbol of the work process  
Symbol  for  welding  machines  suitable  for  working  in 
an environment with a  high risk of electric shock. 
Symbol of the welding current  
Assigned no-load voltage (operating voltage) 
Range of the welding current 
Values of the intermittence cycle (in 10 minutes) 
Values of the assigned welding current  
Values of the conventional loaded voltage 
 
 
 
 


Summary of Contents for MAX 223C PIPELINE

Page 1: ...ALDATRICE INSTRUCTION MANUAL FOR WELDING MACHINE BETRIEBSANLEITUNG FÜR SCHWEIßGERÄTE MANUAL D INSTRUCTION POUR POSTE DES SOUDAGE MAX MAX MAX MAX 223C PIPELINE 223C PIPELINE 223C PIPELINE 223C PIPELINE Info www stelgroup it tel 39 0444 639525 ...

Page 2: ...0444 639682 www stelgroup it The following harmonized standard in force within the EEA has been used in the design EN 60974 1 Arc welding equipment Part 1 Welding power sources EN 60974 10 Arc welding equipment Part 10 Electromagnetic compatibility EMC requirements Additional information Restrictive use Class A equipment intended for use in locations other than residential By signing this document...

Page 3: ...A SALUTE Tenere il capo fuori dalla portata dei fumi Provvedere per una ventilazione adeguata dell area di lavoro Se la ventilazione non è sufficiente usare un aspiratore che aspiri dal basso IL CALORE GLI SCHIZZI DEL METALLO FUSO E LE SCINTILLE POSSONO PROVOCARE INCENDI Non saldare vicino a materiali infiammabili Evitare di portare con sé qualsiasi tipo di combustibile come accendini o fiammiferi...

Page 4: ...di ottenere generatori con peso e dimensioni estremamente contenuti ridotto consumo energetico eccellente risposta dinamica fattore di potenza e rendimenti molto alti caratteristiche di saldatura migliori visualizzazione su display dei dati e delle funzioni impostate I componenti elettronici sono racchiusi in una robusta carpenteria facilmente trasportabile e raffreddati ad aria forzata con ventil...

Page 5: ...tensione di alimentazione MAX 223C PIPELINE 400V 3P 10 e Fuse rating di 16 AT Fuse COLLEGAMENTO Prima di effettuare connessioni elettriche tra il generatore di corrente e l interruttore di linea accertarsi che quest ultimo sia aperto Il quadro di distribuzione deve essere conforme alle normative vigenti nel paese di utilizzo L impianto di rete deve essere di tipo industriale Predisporre una apposi...

Page 6: ... sotto alimentazione non lampeggerà più ATTENZIONE per effettuare la regolazione dell Hot Start bisogna avere la funzione VRD disinserita V R D ATTIVO SOLO IN ELETTRODO GESTIONE V R D La sigla V R D sta per VOLTAGE REDUCTION DEVICE che non è altro che un sistema per la riduzione della tensione a vuoto Quando si installa il V R D in una saldatrice esso riduce la tensione a vuoto massima ad una tens...

Page 7: ...E ELETTRICHE ED ELETTRONICHE Non smaltire le apparecchiature elettriche assieme ai rifiuti normali In ottemperanza alla Direttiva Europea 2002 96 CE sui rifiuti da apparecchiature elettriche ed elettroniche e relativa attuazione nell ambito della legislazione nazionale le apparecchiature elettriche giunte a fine vita devono essere raccolte separatamente e conferite ad un impianto di riciclo ecocom...

Page 8: ...cause burns Keep the tip of the electrode far from your body and from other persons PREVENTION OF ELECTRIC SHOCKS Take the following precautions when working with a welding machine keep yourself and your clothes clean do not be in contact with damp or wet parts when working with the welding machine maintain suitable insulation against electric shock If the operator has to work in a damp environmen...

Page 9: ...tter welding characteristics viewing of the data and of the set functions on the display The electronic components are enclosed in a sturdy structure that is easy to carry and cooled with forced air by fans with low noise production N B This welding machine is not suitable for thawing pipes DELIVERY OF THE MATERIAL The package contains N 1 welding machine N 1 instruction manual Check that all the ...

Page 10: ...operates from the following mains supply voltage MAX 223C PIPELINE 400V 3P 10 e Fuse rating di 16 AT Fuse CONNECTION Before making the electrical connections between the welding machine and the line switch ensure that the switch is turned off The distribution panel must comply with the regulations in force in the country of use The mains system must be of the industrial type For longer connecting ...

Page 11: ...led stop to blink ATTENTION for setting the Hot Start the VRD function must be switched off V R D AVAILABLE ONLY IN MMAMODE V R D MANAGEMENT The initials V R D means VOLTAGE REDUCTION DEVICE which is a system for reducing the no load voltage OCV When the V R D is installed in a welding machine it reduces the maximum no load voltage to a safety voltage which is normally less than 25 V The V R D is ...

Page 12: ...spose of electrical equipment together with normal waste In observance of European Directive 2002 96 EC on Waste Electrical and Electronic Equipment and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get...

Page 13: ...ine entflammbaren Dinge mit sich wie Feuerzeuge oder Streichhölzer Der Lichtbogen kann Brände verursachen Halten Sie die Spitze der Elektrode von Ihrem Körper sowie von Personen in Ihrer Nähe fern VORSICHTSMASSNAHMEN UM EINEN ELEKTROSCHOCK ZU VERHINDERN Treffen Sie folgende Vorkehrungen wenn Sie mit einem Schweißgerät arbeiten Halten Sie sich und Ihre Kleidung sauber Berühren Sie keine feuchten od...

Page 14: ...len Die Mikroprozessorschaltung steuert und optimiert den Transfer des Lichtbogens ungeachtet der Lastschwankung und des Schweißkabelwiderstands Die Steuerung an der Frontplatte ermöglicht ein einfaches Programmieren der Schweißfolge in Abhängigkeit der Arbeitsanforderungen Die eingesetzte Inverter Technologie ermöglicht folgende Punkte Maschinen mit extrem geringem Gewicht und kompakten Abmessung...

Page 15: ...er Staub in das Gerät einsaugt Vermeiden Sie Stöße und Scheuern und setzen sie das Gerät niemals Spritzwasser exzessiven Hitzequellen oder anderen bnormalen Situationen aus NETZSPANNUNG Die Schweißgerate funktioniert von der folgenden Netzspannung MAX 223C PIPELINE 400V 3P 10 mit einer Netz Absicherung von 16 A Fuse ANSCHLUSS Bevor Sie den elektrischen Anschluss zwischen dem Schweißgerät und dem L...

Page 16: ...ie VRD Funktion abgeschaltet werden V R D nur erhältlich im MMA Modus V R D MANAGEMENT Die Buchstaben V R D stehen für VOLTAGE REDUCTION DEVICE welches ein System zur Absenkung der Leerlaufspannung OCV ist Wenn V R D im Schweißgerät installiert ist reduziert es die maximale Leerlaufspannung auf eine Schutzspannung die normalerweise weniger als 25V beträgt Das V R D wird als zusätzliche Hilfe zur A...

Page 17: ...D ELEKTRONISCHEN GERÄTEN Entsorgen Sie keine elektrischen Geräte zusammen mit normalem Müll Gemäß Europäischer Richtlinie 2002 96 EG über Elektro und Elektronik Altgeräte und Umsetzung in nationales Recht müssen verbrauchte Elektro und Elektronikgeräte getrennt gesammelt und einer umweltgerechten Wiederverwertung zugeführt werden Als Eigentümer des Geräts sollten Sie bei Ihrem lokalen Händler Info...

Page 18: ... pour la santé Gardez votre tête loin de fumées Assurer une ventilation adéquate pour la zone de travail Si la ventilation est insuffisante utiliser un aspirateur pour aspirer par le bas CHALEUR les croquis de hot metal et les étincelles peuvent provoquer des incendies Ne pas souder à proximité de matières inflammables Ne pas transporter tout type de carburant tels que les briquets ou des allumett...

Page 19: ...pérationnels La technologie d onduleur utilisé a donné la chance d obtenir Générateurs d un très faible poids et les dimensions Consommation d énergie réduite Excellente réponse dynamique Facteur de puissance et de rendement très élevé Caractéristiques de soudage de meilleure qualité Affichage visuel de données et les fonctions de réglage Les composants électroniques sont enfermés dans un métal ro...

Page 20: ... situations anormales TENSION Le générateur fonctionne avec ces tension d alimentation MAX 223C PIPELINE 400V 3P 10 et Fusible 16 AFusible T CONNEXION Avant d effectuer des connexions électriques entre le générateur de puissance et commutateur de ligne assurez vous que cette dernière est ouverte Le tableau de distribution doit se conformer à la réglementation du pays d utilisation L Réseau du syst...

Page 21: ...ne éteint et la del verte puovoir sous arête de clignoter ATTENTION POUR RÉGLER LA FONCTION DE DÉMARRAGE À HOT START DOIT AVOIR LE VRD DECONNECT V R D Seulement actif dans ÉLECTRODE GESTION V R D Le V R D abréviation signifie SYSTEM DE REDUCTION DE TENSION un système pour réduire la tension de charge a vide Lorsque vous installez le V R D un soudage elle réduit la tension en circuit ouvert maximal...

Page 22: ...T ELECTRONIQUES Ne jetez pas de l équipement électrique avec les déchets normaux Dans le respect de la directive européenne 2002 96 CE relative aux déchets d équipements électriques et électroniques et sa mise en œuvre dans le droit national l équipement électrique arrivé en fin de vie doit être collecté séparément et est retourné à un centre de recyclage respectueux de l environnement En tant que...

Page 23: ...6913400050 23 WIRING DIAGRAM MAX 223C PIPELINE ...

Page 24: ...6913400050 24 EXPLODED VIEW MAX 223C PIPELINE ...

Page 25: ...ntermediate panel Fan Power cable support Power cable Cable grommet Switch Switch support Front and rear panel Rear Fan Support Filter line PCB Secondary power PCB Diodes Heatsink Flyback PCB PCB support Power resistor Left intermediate panel TR XL support Front Fan Support 6607520K 6607540K 620212U0 620148CG 61203600 6202530T 66079120 64188000 66106200 66079700 64274000 66079000 612142 620209CM 6...

Page 26: ...H A NEGATIVE EARTH CLAMP B POSITIVE TIG LIFT TORCH CONNECTOR C PIN 7 PIN CONNECTOR PIN DESCRIPTION 3 SWITCH TORCH 2 TORCH TRIGGER 7 SWITCH TORCH 1 3 SWITCH TORCH 2 MIN 7 SWITCH TORCH 1 2 MAX 5 DOWN REG 1 SENSE 1 PEDAL 6 SENSE 2 RESISTOR 220K 3 MIN 2 MAX 5 REG POT 1 SENSE 1 REMOTE CONTROL 6 SENSE 2 RESISTOR 220K 3 SWITCH TORCH 2 MIN 7 SWITCH TORCH 1 4 UP 5 DOWN 1 SENSE 1 UP DOWN 6 SENSE 2 JUMPER A ...

Page 27: ...E The Hot start supplies a extra current upon starting which allows the electrode to be immediately removed and promptly begin welding The Hot Start is adjustable HOT START 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 time Current extra energy IDEAL SETTING ELECTRODE TYPE DIAMETER CURRENT HOT START ARC FORCE 6013 2 5 80 10 Min RUTILE 6013 3 25 115 10 Min 7018 2 5 90 ...

Page 28: ...6913400050 28 Info www stelgroup it tel 39 0444 639525 ...