– 8 –
– 9 –
GB
GB
1� About this document
Please read carefully and keep in a safe place.
–
Under copyright. Reproduction either in whole or in
part only with our consent.
–
Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
...
Reference to other information in the
document.
2� General safety precautions
!
Disconnect the power supply before
attempting any work on the unit.
• During installation, the electric power cable to be
connected must not be live. Therefore, switch off the
power first and use a voltage tester to make sure the
wiring is off-circuit.
• Installing the LED luminaire involves work on the
mains voltage supply. This work must therefore
be carried out by a qualified electrician in accord-
ance with applicable national wiring regulations and
electrical operating conditions. ( e. g.
DE
- VDE 0100,
AT
- ÖVE-ÖNORM E8001-1,
CH
- SEV 1000 )
• Only use genuine replacement parts.
• Repairs may only be made by specialist workshops.
• The light source in this light may only replaced by the
manufacturer or a service engineer authorised by the
manufacturer or by a similarly qualified person.
3� RS PRO Connect 5100 LED SL
Proper use:
–
Luminaire with LED as the source of light
–
Suitable for installing in rooms exposed to moisture
–
As single luminaire or for interconnection with the
master version with sensors
Suitable for use in an environment in which
conductive dust is expected to settle on the
light.
Package contents
( Fig� 3�1 )
– LED luminaire
– 2 mounting clips
Product dimensions
( Fig� 3�2 )
Product components
( Fig� 3�3 )
A
Screwed cable gland
B
Twist lock
C
Connecting terminal
D
Mounting clamp
E
End caps
F
Light enclosure
4� Electrical connection
Wiring diagram
( Fig. 4.1 )
The supply lead consist of three wires:
L
= phase conductor ( usually black, brown or grey )
N
= neutral conductor ( usually blue )
E
= protective-earth conductor ( green/yellow )
If you are in any doubt, identify the conductors using a
voltage tester; then disconnect from the power supply
again. Connect phase (
L
), neutral conductor (
N
) and
protective-earth conductor (
E
) to the plug-in terminal.
Important
:
Incorrectly wired connections will produce a short
circuit later on in the product or your
fuse box
. In this
case, you must identify the individual conductors once
again and reconnect them. A mains power switch for
turning the unit ON and OFF may of course be installed
in the mains supply lead.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• When installing the LED luminaire, make sure the
installation site is not subject to vibration.
Note:
For wall mounting, the light must be installed horizontally.
Mounting procedure
• Switch OFF power supply
( Fig. 4.1 )
• Mark drill holes
( Fig. 5.1 )
• Drill holes and insert wall plugs
( Fig. 5.2 )
• Screw on mounting clips
( Fig. 5.3 )
• Fit light enclosure
( Fig. 5.4 )
• A click confirms proper engagement
• Open screwed cable gland and twist lock
( Fig. 5.5 )
• Guide connecting cable through screwed cable
gland and twist lock and connect to plug-in terminal
( Fig. 5.6 )
• Close screwed cable gland and twist lock
( Fig. 5.7 )
• Switch ON power supply
( Fig. 5.7 )
6. Maintenance and care
The product requires no maintenance. The light
enclosure can be cleaned with a damp cloth ( without
detergents ) if dirty.
7� Disposal
Electrical and electronic equipment, accessories and
packaging must be recycled in an environmentally
compatible manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Elec-
trical and Electronic Equipment and its implementation
in national law, electrical and electronic equipment no
longer suitable for use must be collected separately
and recycled in an environmentally compatible manner.
8� Manufacturer's Warranty
As purchaser, you are entitled to your statutory rights
against the vendor. If these rights exist in your country,
they are neither curtailed nor restricted by our Warranty
Declaration. We guarantee that your STEINEL Profes-
sional sensor product will remain in perfect condition
and proper working order for a period of 5 years. We
guarantee that this product is free from material-, man-
ufacturing- and design flaws. In addition, we guarantee
that all electronic components and cables function in
the proper manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your product
complete and carriage paid with the original receipt of
purchase, which must show the date of purchase and
product designation, either to your retailer or contact
us at
STEINEL ( UK ) Limited, 25 Manasty Road, Axis
Park, Orton Southgate, Peterborough, PE2 6UP
, for
a returns number. For this reason, we recommend that
you keep your receipt of purchase in a safe place until
the warranty period expires. STEINEL shall assume
no liability for the costs or risks involved in returning a
product.
For information on making claims under the terms of
the warranty, please go to
www�steinel-professional�
de/garantie
If you have a warranty claim or would like to ask any
question regarding your product, you are welcome to
call us at any time on our Service Hotline
01733 366700
.
MANUFACTURER'S
1
3
5
Y E A R
G B
WARRANTY
MANUFACTURER'S
Y E A R
WARRANTY
MANUFACTURER'S
Y E A R
WARRANTY
Dimensions ( H × L × W )
58 × 1370 × 87 mm
Power supply
220-240 V / 50/60 Hz
Output
30 W / 4310 lm / 143 lm/W
Colour temperature
4000 K ( neutral white )
Power factor
0.93
Mains current
142 mA
LED life expectancy
60,000 h / L80B10
Max. area covered
approx. 50 m
2
Temperature range
-20°C to +40°C
IP rating
IP66
Protection class
II
Material
PC IK07
Power consumption
0.45 W
Through-wiring
max. 16 A
9� Technical specifications