Package contents for surface-mounted installation
(Fig� 3�1)
Package contents for concealed installation
(Fig� 3�2)
Product components (Fig� 3�3)
A
Load module, power supply lead, surface-mounted
B
Load module, power supply lead, concealed installation
C
Designer trim, round or square
D
Sensor module
E
Shroud
Product dimensions
Surface-mounted / concealed
(Fig� 3�4)
IS 3360 DALI, IS 3360 MX DALI, IS 345 DALI
Surface-mounted / concealed
(Fig� 3�5)
IS 345 MX DALI
Surface-mounted / wall-mounted
(Fig� 3�6)
IS 3180 DALI
4� Electrical installation
The mounting location should be at least 50 cm away from other lights because heat
radiated from these may activate the system.
An optional corner wall mount (product no. 648015 black or 035174 white) is available
for mounting the IS 3180 DALI.
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N
= neutral conductor (usually blue)
PE
= protective-earth conductor (green/yellow)
Wiring example
(Fig� 4�1)
– Surface-mounted installation
If the rubber seal is damaged, the cable entry openings must be sealed with an M16 or
M20 (at least IP 54) double seal cable gland.
For mounting the IS 3180 DALI on the wall, a condensation water drainage hole
(Ø 5 mm drill bit) is marked next to the rubber seal. This must be opened if necessary.
Master/slave (Fig� 4�2)
The DALI sensor is suitable for use in master/slave networks. In this case, the DALI sen-
sor is the master, the LiveLink sensor the slave. The master/slave configuration permits
detection of movement in larger rooms or spaces (load connected = master, no load =
slave). The level of brightness prevailing in the room is only evaluated at the master.
The slaves report movements detected to the master. Lighting is only switched ON and
OFF by the master. As many as 30 users can be connected.
GB
1� About this document
– Please read carefully and keep in a safe place.
– Under copyright.
Reproduction either in whole or in part only with our consent.
– Subject to change in the interest of technical progress.
Symbols
Hazard warning!
Reference to other information in the document�
2� General safety precautions
Disconnect the power supply before attempting any work on the sensor�
• During installation, the electric power cable to be connected must not be live.
Therefore, switch off the power first and use a voltage tester to make sure the wiring
is off-circuit.
• Installing the sensor involves work on the mains power supply. This work must there-
fore be carried out professionally in accordance with national wiring regulations and
electrical operating conditions. (
DE
- VDE 0100,
AT
- ÖVE-EN 1,
CH
- SEV 1000)
3� IS 3360, IS 3360 MX, IS 345, IS 345 MX, IS 3180 DALI
Proper use
– IS 3360 MX DALI and IS 345 MX DALI are suitable for indoor ceiling mounting.
– IS 3360 DALI and IS 345 DALI are suitable for indoor and outdoor ceiling mounting.
– IS 3180 DALI is suitable for wall mounting indoors and outdoors.
– The concealed versions are only suitable for installing indoors.
The motion detector is equipped with pyro sensors that detect the invisible heat
emitted from moving objects (people, animals etc.). The heat detected in this way is
converted electronically into a signal that switches a connected load ON (e.g. a light).
Heat is not detected through obstacles, such as walls or panes of glass.
Heat radiation of this type will, therefore, not trigger the sensor.
Optionally, all function settings can be made via the RC5, RC8 remote controls as well
as the Smart Remote.
(
➔
"7� Accessories")
!
...
!
GB