Translation of the original operating instructions

GB

   During installation, the 

electrical wiring you are 
connecting must be dead.

 

Therefore, switch off the 
power first and use a volt-
age tester to make sure the 
wiring is off circuit.

   Installing this unit involves 

work on the mains voltage 

supply. This work must 
therefore be carried out by 
a qualified electrician in 
accordance with applicable 
national wiring regulations 
and electrical operating 
conditions (

D

- VDE 0100, 

A

-ÖVE-ÖNORM E8001-1, 

-SEV 1000).

   Only use genuine replace-

ment parts.

   Do not dismantle the unit 

yourself. It must only be 
repaired by a specialist 
workshop.

S

afety precautions

Installation

The IS 2360 is a sensor for mounting on indoor and outdoor ceilings.

L

 = 

 

live conductor (usually 
black, brown or grey)

N

 = 

 

neutral conductor 
(usually blue)

PE

 =  any protective earth 

conductor (green/yellow)

Note:

 Loop the protective-

earth conductor through if 
necessary. A mains power 
switch for turning the unit 
ON and OFF may of course 
be installed in the mains 
supply lead.

Important:

 Reversing the 

connections may result in 
damage to the unit.

If ncecessary, the conden-
sation water drainage hole 

 must be drilled open with 

a 5 mm drill bit.

Principle

Movement triggers lights, 
alarms and many other de-
vices. For your convenience, 
safety and peace of mind. 
The integrated pyroelectric 
infrared detector senses the 

invisible heat radiated from 
moving objects (people, ani-
mals, etc.). The heat detected 
in this way is converted elec-
tronically into a signal that 
switches ON the connected 

load. Heat is not detected 
through obstacles, such as 
walls or panes of glass, and 
will therefore not activate the 
light.

S

ystem Components

 Wall mount

  Load module with lens

 Designer trim

 Sealing plug

 Light-level setting

 Time setting

 

Condensation water    

 drainage 

hole

 Concealed 

wiring

 Surface wiring

Functions

Light-level setting 

(Factory setting: daylight operation 2000 lux):

The sensor's response threshold can be infinitely varied from 
2 – 2000 lux.

Control dial set to 

 = daylight operation approx. 2000 lux.

Control dial set to

 

 

= twilight operation approx. 2 lux. 

To adjust the detection zone in daylight, the control dial must be 
set to

 

 

(daylight operation).

Time setting 

(Factory setting: 8 sec.)

Light ON duration can be infinitely varied from 8 sec. to 35 min.

Control dial set to 

 = shortest time (8 sec.)

Control dial set to 

+

 = longest time (35 min.)

When setting the detection zone, it is recommended to select 
the shortest time 

.

Declaration of Conformity

This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC

2 – 2000 lux

8 sec. – 35 min.