Translation of the original operating instructions
GB
During installation, the
electrical wiring you are
connecting must be dead.
Therefore, switch off the
power first and use a volt-
age tester to make sure the
wiring is off circuit.
Installing this unit involves
work on the mains voltage
supply. This work must
therefore be carried out by
a qualified electrician in
accordance with applicable
national wiring regulations
and electrical operating
conditions (
D
- VDE 0100,
A
-ÖVE-ÖNORM E8001-1,
-SEV 1000).
Only use genuine replace-
ment parts.
Do not dismantle the unit
yourself. It must only be
repaired by a specialist
workshop.
S
afety precautions
Installation
The IS 2360 is a sensor for mounting on indoor and outdoor ceilings.
L
=
live conductor (usually
black, brown or grey)
N
=
neutral conductor
(usually blue)
PE
= any protective earth
conductor (green/yellow)
Note:
Loop the protective-
earth conductor through if
necessary. A mains power
switch for turning the unit
ON and OFF may of course
be installed in the mains
supply lead.
Important:
Reversing the
connections may result in
damage to the unit.
If ncecessary, the conden-
sation water drainage hole
must be drilled open with
a 5 mm drill bit.
Principle
Movement triggers lights,
alarms and many other de-
vices. For your convenience,
safety and peace of mind.
The integrated pyroelectric
infrared detector senses the
invisible heat radiated from
moving objects (people, ani-
mals, etc.). The heat detected
in this way is converted elec-
tronically into a signal that
switches ON the connected
load. Heat is not detected
through obstacles, such as
walls or panes of glass, and
will therefore not activate the
light.
S
ystem Components
Wall mount
Load module with lens
Designer trim
Sealing plug
Light-level setting
Time setting
Condensation water
drainage
hole
Concealed
wiring
Surface wiring
Functions
Light-level setting
(Factory setting: daylight operation 2000 lux):
The sensor's response threshold can be infinitely varied from
2 – 2000 lux.
Control dial set to
= daylight operation approx. 2000 lux.
Control dial set to
= twilight operation approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be
set to
(daylight operation).
–
Time setting
(Factory setting: 8 sec.)
Light ON duration can be infinitely varied from 8 sec. to 35 min.
Control dial set to
–
= shortest time (8 sec.)
Control dial set to
+
= longest time (35 min.)
When setting the detection zone, it is recommended to select
the shortest time
–
.
Declaration of Conformity
This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC
2 – 2000 lux
8 sec. – 35 min.