background image

- 18 -

- 19 -

segments to limit reach as required. 

Inadvertent triggering is ruled out or 

the sensor can be targeted to watch 

over danger spots. 

(Fig. 5.4)

7. Integration into Z-Wave 

networks

This product can be operated in any  

Z-Wave network with other Z-Wave 

certified devices from other manu-

facturers. All non-battery operated 

nodes within the network will act as 

repeaters regardless of vendor to 

increase reliability of the network.

Inclusion

Add

Exclusion

Remove

These instructions for including and 

excluding STEINEL Z-Wave products 

have been written for the Smart 

Friends system. They may not always 

apply to other Z-Wave products. You 

will find further details in the descrip-

tion of your Z-Wave controller. (To 

start the motion detector's inclusion 

or exclusion mode, turn the device's 

control dial   to "Set" and back to 

"0" within 5 seconds).

Following exclusion, all configuration 

parameters (time, sensitivity etc.) 

remain intact until next inclusion and 

the light now works in standalone 

mode – as a result, Z-Wave can also 

be used for the light’s standalone 

setting.

6. Function

The motion detector will also work 

without being integrated into a 

Z-Wave network. In this case, the 

time setting is permanently set to 

3 minutes. When putting the motion 

detector into operation, it will switch 

OFF after the 10-second calibration 

phase and is then activated for sen-

sor mode. The motion detector can 

now be integrated into the Z-Wave 

network.

The settings can be made via the 

control dials or via Z-Wave network. 

The settings last selected will always 

be in effect regardless of whether 

they were made via the control dials 

or via Z-Wave network.

Factory settings

Twilight level  : 2000 lux

Time setting: 3 min

Twilight setting (Fig. 5.1/C)  

can be infinitely varied
Control dial set to 

 =  

twilight operation, approx. 2 lux
Control dial set to 

 =  

daylight operation, approx. 2000 lux

Note:

 To adjust the detection zone in 

daylight, the control dial must be set 

to 

 = daylight operation.

Reach setting/adjustment

The detection zone can be optimised 

to suit requirements.
Sensor unit

 

– Sensor unit swivels through 180°. 

(Fig. 5.2)

 

– Sensor unit tilts through 90°. 

(Fig. 5.5) 

Adhesive shrouds

 (Fig. 5.3)

The film shroud can be used for 

masking out any number of lens 

3

  To put the device into exclusion 

mode, turn the device's control dial 

 to "Set" and back to "0" within 

5 seconds. The red status LED   

lights up to show that this mode is 

selected.

4

  The app displays a confirmation 

message once exclusion has been 

successfully completed.

Setting IS 140-2 with the app

 

– After programming, an ON/OFF 

scene is automatically created in 

the app.

 

– The following setting values are 

then automatically stored:

a)  Twilight setting = control-dial 

setting

b)  Time setting = 3 min switch-

OFF delay

 

– The twilight and time settings can 

be selected to the accuracy of a 

lux / second in the "Scene" menu.

Resetting the IS 140-2 to factory 

settings:

Please only perform these steps if the 

main network controller is missing or 

not working for other reasons.

1

  Turn the device's control dial   to 

"Set" and move it to "Reset" within 

5 seconds.

2

   Status  LED 

 briefly flashes to 

show that the light has been reset.

3

  The device is now no longer includ-

ed in the Z-Wave system and has 

been reset to factory settings.

Note:

 the current firmware version for 

the light is available for downloading 

from 

z-wave.steinel.de

.

Z-Wave control dial

 

(E)

Control dial for 

inclusion and 

exclusion as well as 

for returning the 

device to the factory 

setting.

Adding IS 140-2 to the  

Smart Friends system:
1

   Download Smart Friends app from 

the app store.

2

  In the rooms view, activate the  

edit mode.

3

  Select the chosen room and press 

the "Add device" button.

4

  To put the device into inclusion 

mode, turn the device's control dial 

 to "Set" and back to "0" within 

5 seconds. Status LED   lights up 

to show that this mode is selected.

5

  The app displays a confirmation 

message once inclusion has been 

successfully completed.

Removing IS 140-2 from the  

Smart Friends system:
1

  In the rooms view, activate the  

edit mode.

2

  Select the device in the chosen 

room and press the "delete" 

 

button. Press delete and follow the 

instructions in the app.

Summary of Contents for IS 140-2 Z-Wave

Page 1: ...000000000 07 2013 Technische nderungen vorbehalten STEINEL Vertrieb GmbH Dieselstra e 80 84 33442 Herzebrock Clarholz Tel 49 5245 448 188 www steinel de Contact www steinel de contact DE GB FR NL IT...

Page 2: ...1 99 86 107 82 3 4 E D C B A 3 5 L N L N L N L N I O F Textteil beachten Follow written instructions Suivre les instructions ci apr s Tekstpassage in acht nemen Seguire attentamente le istruzioni DE 8...

Page 3: ...4 5 4 1 max 14 m 2 m 4 2 max 14 m 4 3 5 m 4 4 4 5 4 6 4 7 6 4 8 4 9 4 10 4 11 5 4 12 L L N 4 13 4 14 4 15 I O 5 1 C E...

Page 4: ...6 7 5 2 180 90 90 5 3 5 4 5 5 90 90...

Page 5: ...Z Wave controllers it is recommended to use the Smart Friends box This smart home control centre can be used for interconnect ing Z Wave products from STEINEL and the Smart Friends products from ABUS...

Page 6: ...Reach setting adjustment The detection zone can be optimised to suit requirements Sensor unit Sensor unit swivels through 180 Fig 5 2 Sensor unit tilts through 90 Fig 5 5 Adhesive shrouds Fig 5 3 The...

Page 7: ...will remedy defects caused by material flaws or manufacturing faults The warranty will be met by repair or replacement of defective parts at our own discretion The warranty shall not cover damage to w...

Page 8: ...heck detection zone Check detection zone Tilt sensor higher or fit shrouds to target sensor adjust detection zone or fit shrouds Switches ON when it should not Wind is moving trees and bushes in the d...

Reviews: