– 16 –
11. Troubleshooting
Malfunction
Cause
Remedy
Light without power
■
Fuse faulty, not switched ON,
break in wiring
■
Fit new fuse, turn ON mains
switch, check wiring with voltage
tester
Light not switching ON
■
Surroundings still too bright
(S only)
■
Mains switch OFF
■
Fuse blown
■
Detection zone not correctly
adjusted (S only)
■
Wait until response threshold is
reached or adjust setting
■
Switch ON
■
Fit new fuse, check connection
if necessary
■
Readjust
Light not switching OFF
■
Continued movement within
the detection zone (S only)
■
Check detection zone and
readjust if necessary
Light switches ON when it
should not
■
Cars in the street are detected,
for example (S only)
■
Check detection zone and
readjust if necessary
Changing reach
■
Differing ambient temperatures
(S only)
■
When it is cold, shorten reach
by tilting sensor down,
move it up in warm weather