STEINEL PROFESSIONAL sensIQ S Information Download Page 5

- 15 -

- 14 -

Connection examples

I     Light without existing neutral conductor 
II    Light fitted with a neutral conductor 
III   Connection by means of two-circuit  

single-interruption switch for manual 
and automatic operation 

IV   Connection by means of two-way switch 

for manual override and automatic  
operation

 

     Setting I:  Automatic operation 
     Position II: Manual operation 

Light ON permanently 

     Note: 

The system cannot be switched OFF, 

it is only possible to select operation at 
setting I or II.

a)   

Loads, lighting of 2000 W max.  
(see Technical specifications) 

b)

  Sensor connection terminals 

c)

  Indoor switch 

d)   

Indoor series switch, manual, automatic 

e)   

Indoor two-way switch, automatic  
operation, manual override

Technical specifications

Dimensions (H × W × D):

74 × 114 × 128 mm 

Output: 

 

 

    

Power supply:

100 - 240 V AC  50/60 Hz 

Minimum load: 

3 W 

Angle of coverage:

300° with 180° angle of aperture, as well as sneak-by guard  
for coverage directly below the sensor. Capability of masking  
out individual segments 

Reach:

Adjustable in 3 directions independently from one another by  
control dial, (2  – 20 m max., temperature-stabilised) 

Sensor technology:

4 sensors, 6 levels for long-distance detection and  
5 for sneak-by guard, 1360 switching zones 

Time setting:

5 sec. – 15 min., pulse mode 

Twilight setting:

2 – 1000 lux 

Manual override:

selectable (4 hrs.) / (by remote control only) 

Permanently OFF:

selectable (4 hrs.) / (by remote control only) 

IP rating:

IP54 through 2-component injection mould technology 

 

Incandescent / halogen lamp load

2000 W

Fluorescent-lamp electronic ballasts 

1500 W

Fluorescent lamps, uncorrected 

1000 VA

Fluorescent lamps, series-corrected

700 VA

Fluorescent lamps, parallel-corrected

1000 VA

Low-voltage halogen lamps

1000 VA

LED < 2 W 

100 W

2 W < LED < 8 W 

300 W

LED > 8 W 

600 W

Capacitive load

176 μF

GB  Installation instructions 

Principle

Dear Customer, 
 

Congratulations on purchasing your new 
STEINEL Infrared Sensor and thank you for the 
confidence you have shown in us. You have 
chosen a pioneering product that has been 
manufactured, tested and packed with the 
greatest care.

Please familiarise yourself with these instruc-
tions before attempting to install the sensor  
light because prolonged reliable and trouble-
free operation will only be ensured if it is fitted 
properly. 
We hope your new Infrared Sensor will give you 
lasting satisfaction.

The unit is equipped with pyro sensors that  
detect the invisible heat emitted from moving 
objects (people, animals etc.). The heat thus 
detected is electronically converted and 
switches ON connected consumers (e.g.  

a light). No heat radiation is detected through 
obstacles such as walls or panes of glass  
for example and consequently no switching 
occurs.

Safety warnings

During installation, the electrical wiring you 
are connecting must be dead. Therefore, 
switch off the power first and use a voltage 
tester to check that the power supply is  
disconnected. 

Installing the sensor involves work on  
the mains power supply. This work must 
therefore be carried out professionally in 

accordance with applicable national wiring 
regulations and electrical operating condi-
tions. (

DE

-VDE 0100, 

AT

-ÖVE/ÖNORM E 

8001-1, 

CH

-SEV 1000) 

Only use genuine replacement parts. 

Repairs may only be carried out by special-
ist workshops.

Installation

The site of installation should be at least 50 cm 
away from another light because heat radiated 
from it may activate the system. 
In order to achieve optimum detection, the 
sensor must be installed tangentially to the 
walking direction. 
 
A corner wall mount is included for mounting 
on outside corners. 
 
The mains supply lead is a 3-core cable  
(max. conductor Ø 9 mm): 

=

 

phase (usually black, brown or grey) 

N

= neutral conductor 

PE

= protective-earth conductor 

If the rubber seal is damaged, the cable entry 
openings must be sealed with an M 16 or M 20 
double seal cable gland. 
 
A condensation water drainage hole is outlined 
in the housing 

. This can be opened for wall  

installation. 
 
Wall mount 

 must be renewed if any subse-

quent change is made to wiring run. 
 
To release the cable, the connection terminal 
must be pressed in with a flat-tip screwdriver 
at the notch provided for this purpose 

.

System components

Surface-mounting adapter 

Sealing plug 

Film shroud 

Lens enclosure 

Condensation water drainage hole 

Wall mount / sensor unit 

 

Corner wall mount 

Plug-in terminals 

Locking screw 

Light-level setting 

Time setting 

Reach setting 

    Mains connection, concealed wiring 
    Mains connection, surface wiring

II

I

GB