background image

STEINDORFF

®

 

 

- 2 -

 

General Rules

 

NYMCS-VM400 is a multifunctional digital microscope. It realized Full HD, high object distance, multifunction, 
multi-output at the same time. With help of the Andonstar measuring software, it can easily meet many different 
requirements in many industries, such as industrial overhaul and teaching demonstration. And it’s appearance 
design  combines  more  ergonomic  consideration,  provides  users  better  experience.  We  sincerely  wish  this 
product can release your eyes and improve your work quality. Thanks for your support.   
 

This operation manual allows you to work safely with the digital Microscope. Please keep this manual for your 

information. Liability is void for any damage caused by not follow this manual.   

Failure to follow the warnings and instructions may cause electric shock, fire and/or serious injury. 

Not following this note can cause permanent damage to the device. 

Storage and transport: Improper transport can harm the device; Always transport this device in the provided 

box in order to prevent damage. 

Information on disposal: Electronic equipment does not belong to domestic waste, but must be disposed in 

accordance with the applicable statutory provisions. 

In order to bring customers a better experience, we may change the product a little bit during perfecting it. The 

description in this instruction is for reference ONLY. Thanks for understanding. 

Safety 

1.Keep the tool dry, clean, free from oil, water, gas or other materials capable of causing corrosion. 
2.This appliance is not intended for use by people with limited physical, sensory or mental capabilities. 
3.Keep bystanders, children away while operating the tool. 
4.Do not overreach, keep proper footing and balance at all time. 
 

Basic Parameters 

Image sensor 

3 Mega Pixels HD Sensor   

Video output 

1080P Full HD (via HDMI) ;720P (via PC) 

Video format 

MOV 

Magnification ratio 

Up to 260x (HDMI monitor 22 inch) 

Photo resolution 

12M 

Photo format 

JPEG 

Focus range 

5cm to 15cm 

Frame rate 

Max 30f/s under 600 Lux Brightness 

Video-output interface 

HDMI/AV   

Storage 

Micro-SD card, up to 32G (option) 

PC support 

Yes, for Windows XP/7/8/10, PC software with measurement (gift) 

Power source 

5V/2A 

Stand size 

20cm*12cm*17cm 

Screen size 

5 inch 

Accessories 

Stand*1, Power Adaptor*1, USB Cable*1, HDMI Cable*1, Manual*1, 
IR controller*1 

Packing data 

28*22*17cm/1.9kg 

Summary of Contents for NYMCS-VM400

Page 1: ...STEINDORFF NYMCS VM400 Instructions...

Page 2: ...ameters 2 Parts List 3 Main Device 3 Remote Controller 4 Connect Outputs 5 General Use 6 Use Individually 6 HDMI 7 USB 7 Software Installation 7 Software Operation 8 Icons Definitions 8 Interface Defi...

Page 3: ...lectronic equipment does not belong to domestic waste but must be disposed in accordance with the applicable statutory provisions In order to bring customers a better experience we may change the prod...

Page 4: ...EINDORFF 3 Parts List Main Device Fasten screw It aim to adjust the compactness between the Lifting stand and the Distance controllers so users can fasten the distance from the lens to the object tabl...

Page 5: ...the file when it s recording So the video file which has been locked won t be covered by new files when the memory card is full Sharpness up down there are three levels of sharpness Soft Normal Strong...

Page 6: ...them AV output You need a separated AV cable to connect the device to the monitor when you need to use AV output There is no AV cable in the standard configuration Memory card In order to save video...

Page 7: ...e UP DOWN to zoom in out To switch mode 1 Press M shortly Or press the Mode on the remote 2 Icons definition in different modes standby mode capture mode record mode image playback mode video playback...

Page 8: ...ther equipment So it s normal that when you use it as HDMI output the 5 inch screen keeps being dark You still can take pictures and save them if you have a memory card inside the microscope But you c...

Page 9: ...stance of a line and a circle Radius length Distance of 2 horizontal points Add a square mark Distance of 2 vertical points Add a circle mark Distance of any 2 points Add text Measuring a rectangular...

Page 10: ...w all pictures they ve captured Users can also edit the picture by right clicking the picture and open it in the main operating window Choose View Toolbars and Docking Windows Picture browser to show...

Page 11: ...Shows the size of the Calibrations Users can apply whole view Users Can or delete the one they want change it in File Videosetting Video capture pin S Where to set new Shows all results of Calibrators...

Page 12: ...any more 2 In the Calibration management set the name and unit length of the new calibration refer the picture on the right Then click Calibration meanwhile the in the toolbar should have been chosen...

Page 13: ...ce the results of measuring in a proper place around the target 3 Special Effect Includes Edge detection Inverse color Flip horizontal Relief Sharpen and Smooth Steps 1 Choose the special effect you n...

Page 14: ...on or initiator procedure Please confirm that in the system there are Microsoft Net Framework 4 0 and Microsoft Visual C 2010 Runtimes 2 The software works fine but the software can not recognize the...

Page 15: ...ly high temperature environment etc 3 If the fault caused by accident oversight mis operation or natural disasters etc 4 If the fault caused by people who are not belong to authorized organizations of...

Reviews: