PACKING LIST
The EF110 pump is supplied complete with:
-
Bracket for wall installation
-
Standard kit including suction and head tube, foot filter and injection valve
-
Power cable, 1.5 m (internally pre-wired)
-
Instruction manual
TECHNICAL DATA
Flow rate / Pressure
1.8 l/h @ 1 bar, other versions upon request (0.6, 1.2, 2.4 l/h @ 1 bar)
Suction / Delivery Hoses
4x6 mm, PVC Crystal
Materials
Case:
PP
Front:
Lexan control panel,
polycarbonate transparent protection
Roller-holder: PBT
Rollers:
Delrin (self-lubricant)
Internal tube: Santoprene (or silicone)
Connections: PP
Environment
Working temperature
max 45°C
Storage temperature
max 60°C
RH
max 90% noncondensing
Protection Rate
IP54
Dimensions
100 x 160 x 135 mm
Weight
approx. 2 kg
Power Supply
230 V~, 50 Hz, single phase
Power Consumption
max 10 VA
Electrical Protection
Fuse 1 A (@ 230 V~), 5x20 mm
Display
LED, 3 digit
Level Input
on proper connector, accept ohmic contact from level sensor,
5 V / 5 mA
pH / ORP input
on BNC connector, input impedance greater than 10^12
Ω
,
precision better than 1% FS, repeatability better than 0.2% FS
Measure Ranges
0.00 to 14.00 pH; 0 to +1000 mV (ORP)
PRINCIPLE OF OPERATIONS
The principle of operation of the peristaltic pumps is based on the pressure and subsequent release of the
internal tube by the roller mounted on the roller-holder, which is driven by the motor. The dual action of
pressure and release of the tube generates a suction force along the tube itself which primes the liquid
and guide it to the injection line.
The command is sent to the motor by the electronic unit according to the program, to the detected
measurement and to the absence of alarms / errors.
These pumps are also equipped with a built-in instrument, that detects and manages pH and redox
measurements.