Page 1: ...Owner s Manual Generstor SP GG120 Injury II Must ReadAnd Unde stand n_ FOR SERVIC CALL aQO Oa_ _OQt PARA SERVICIQ LLAM _lD_m_im_lIJ_lgP A...

Page 2: ...her partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far a...

Page 3: ...ing Specifications Wiring Diagram Page 3 4 5 6 14 15 16 22 23 24 25 26 27 Warning Read and understand all safety precautions in this manual before operating Failure to comply with instructions in this...

Page 4: ...hours at the service center location and the availability of replacement parts All decisions of Steele with regard to this limited warranty shall be final This warranty gives you specific legal rights...

Page 5: ...ed oil adjustments or other installation and start up costs o Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period o...

Page 6: ...s Be sure to retain them for future use WARNING WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBiLiTY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED CAUTION CAUTIONS INDICATE A POSSIBILITY...

Page 7: ...ery powered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You could have carbon monoxide...

Page 8: ...or hot engine shutdown If this occurs open exhaust system drain plugs if equipped and allow the gases to dissipate before attempting to restart the generator Use only engine manufacturer recommended f...

Page 9: ...ized plug where one blade is wider than the other This plug fits in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qua...

Page 10: ...lectrical characteristics and rated capacities of the generator o Before servicing equipment powered by the generator disconnect the equipment from its power input o Keep all electrical equipment clea...

Page 11: ...turn it on or off Any generator that cannot be controlled with the power switch is dangerous and must be replaced Generator Use and Care Make sure the power switch is in its OFF position and disconnec...

Page 12: ...nce instructions may create a risk of electric shock or injury Heart Pacemakers WARNING PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN S BEFORE USING THIS PRODUCT ELECTROMAGNETIC FIELDS IN CLOS...

Page 13: ...he generator frame at its low side o For trailer installation the generator should be mounted on the center point of the trailer over the wheels The trailer must be capable of supporting the weight of...

Page 14: ...fety eye goggles and safety hat o Do not alter or adjust any part of the generator that is assembled and supplied by the man ufacturer o Always follow and complete scheduled engine and generator maint...

Page 15: ...re to use only UL approved cords having the correct gauge and length according to the following table Nameplate Amps full load Cord Lengths oft 5oft 5off _ooft _ooft _5oft _5off 2oo ft 0 5 16 AWG 16 A...

Page 16: ...Owner s al3ual Assembly There is no assembly required with this generator 15...

Page 17: ...GINE S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE FILL THE ENGINE S CRANKCASE UNTIL THE OiL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DIPSTICK THEN SCREW THE DIPSTICK BACK INTO...

Page 18: ...hasenoughoil and fuel Alsodisconnectall loads from generator Turn the fuel valve to the OPEN position Put the Choke lever to the CHOKE position L _ Turn the engine switch to the ON position Pull the...

Page 19: ...Owner s anual Operation cont d Shutting Down Generator NOTE Disconnectall loadsfrom generator Turn the engine switch to the OFF position Turn the fuel valve to the CLOSE position 18...

Page 20: ...SE OF AN APPROVED LiNE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT STEELE iS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LiNE CONDiTiONER generator is runn...

Page 21: ...art and run the engine as described above 3 When finished using the generator turn the engine power switch to its OFF position Turn the fuel valve to its OFF position 4 After the engine and generator...

Page 22: ...acked or chipped Clean the spark plug with a wire brush if it is to be reused 4 Measure the plug gap with a feeler gauge 5 Check that the spark plug washer is in good condition 6 After the spark plug...

Page 23: ...qualified service technician before further use Do not use damaged equipment o Before each use make sure the engine s oil and fue levels are adequate If necessary fill the crankcase until the oil lev...

Page 24: ...quired Check the oil level o Fil fuel o Check recoil start Check air intake and cooling area Check fuel hose for cracks or damage Check oil o Check and adjust idle speed o Check air cleaner filter o C...

Page 25: ...WEIGHS APPROXIMATELY 53 POUNDS USE CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING IT TO THE iNSTALLATION LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Locat...

Page 26: ...the concrete slab using 3 8 diameter expansion anchor bolts not supplied Grounding NOTE IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED ELECTRICIAN PERFORM THIS PROCEDURE Connect a 6 AWG grounding...

Page 27: ...n Backfires Skips Overheats High Fuel Specifications GENERATOR Model 1200 Type Single Phase Frequency 60Hz Voltage 120 v Max 1200 w Rated 1050 w AC Output 120 v 8 75 DC Output 12 v 8 3 Amps ENGINE Typ...

Page 28: ..._ _milllkllf f lllml ii 1 i Olt w_p_ U_ I r i i i r i I i i i i w i STATOll _NF I i Ihdll ilktk CONTROL PANEL MUll STop Smt r ll 1 _ _ _ IC _ IlltHtt i i l m i i I _ i i _ i I I I i _lln i llt l IN _...

Page 29: ...00 A 10 SP GG 1200 A 11 SP GG 1200 A 12 Description FLANGE BOLT M6 x 12 CLIP HEAD COVER COMP HEAD COVER PACKING FLANGE BOLT M8 X 55 SPARK PLUG EXHAUST PIPE STUD BOLT CYLINDER HEAD COME CARBURETOR STUD...

Page 30: ...CM B 15 SP GG 120CM B 16 Description FLANGE BOLT M6 x 12 OIL LEVEL SWITCH ASSY CRANK CASE BALL BEARING 6203 WASHER 8 3 17 1 LOCK PIN 10mm GOVERNOR ARM SHAFT SNAP RING 8 DRAIN PLUG WASHER 12mm DRAIN PL...

Page 31: ...P GG120CM C 05 SP GG120CM C 06 SP GG120CM C 07 SP GG120CM C 08 Description FLANGE BOLT M6 x 25 OIL SEAL _ 30X _ 17X6 CRANKCASE COVER OIL SCALE SEAL RING OIL SCALE DOWEL PIN _ 8 12 CRANKCASE COVER PAD...

Page 32: ...Crankshaft system assy SP Part No SP GG120CM D 01 Description CRANKSHAFT COMP Part No GE90 D 01 4...

Page 33: ...0 E 06 SP GG1200 E 07 SP GG1200 E 08 SP GG1200 E 09 SP GG1200 E 10 Description COMPRESSION RING A COMPRESSION RING B OIL RING A OIL RING B PISTON PIN CLIP 14mm PISTON PIN PISTON CONNECTION ROD CONNECT...

Page 34: ...GG1200 F 08 SP GG1200 F 09 SP GG1200 F 10 SP GG1200 F 11 SP GG1200 F 12 SP GG1200 F 13 SP GG1200 F 14 SP GG1200 F 15 SP GG1200 F 16 5 8 5 GE90 F 04 GE90 F 05 GE90 F 06 GE90 F 07 GE90 F 08 GE90 F 09 G...

Page 35: ...SP GG1200 G 04 SP GG1200 G 05 SP GG1200 G 06 SP GG1200 G 07 SP GG1200 G 08 SP GG1200 G 09 SP GG 1200 G 10 SP GG1200 G 11 SP GG1200 G 12 SPRING FRICTION STARTER RATCHET RETURN SPRING RECOIL STARTER RE...

Page 36: ...1 SP Part No Description SP GG 1200 H 01 FLANGE BOLT M6 12 GE90 A 01 SP GG 1200 H 02 SHROUD G E90 H 01 SP GG1200 H 03 SIDE PLACE A GE90 H 02 SP GG1200 H 04 SIDE PLACE B GE90 H 03 SP GG1200 H 05 FAN C...

Page 37: ...Carburetor system assy I Description SP Part No Part No SP GG1200 1 01 CARBURETOR ASSY GE90 1 01 SP GG 1200 1 02 CARBU RETOR GASKET GE90 1 02 SP GG1200 1 03 CARBURETORINSULATINGPLATE GE90 1 03 9...

Page 38: ...Part No SP GG1200 J 01 SP GG1200 J 02 SP GG1200 J 03 SP GG1200 J 04 SP GG1200 J 05 Description FLYWHEEL SPECIAL WOODRUFF KEY COOLING FAN STARTER PULLEY FLYWHEEL NUT M12 Part No GE90 J 01 GE90 J 02 GE...

Page 39: ...m assy 1 SP Part No Description Part No SP GG1200 K 01 SPARK PLUG CAP GE90 K 01 SP GG1200 K 02 IGNITION GOIL ASSY GE90 K 02 SP GG1200 K 03 STOP SWITCH CORD GE90 K 03 SP GG1200 K 04 FLANGE BOLT M6 20 G...

Page 40: ...07 SP GG1200 L 08 SP GG1200 L 09 SP GG1200 L 10 Description CONTROL ASSY CONTROL BASE COME CONTROL ADJUSTING SPRING PAN SCREW M5 30 FLANGE BOLT M6 8 GOVERNOR SPRING GOVERNOR ARM FLANGE NUT M M6 GOVERN...

Page 41: ...P GG1200 M 09 44 z Description Part No MUFFLER COME FLANGE NUT _ OBSTRUCT COMBUSTIONSPONGE FLANGE BOLT M6 x 12 MUFFLER SIDE PROTECTOR MUFFLER SIDEPROTECTOR ASBESTOS MUFFLER TOPPROTECTOR ASBESTOS MUFFL...

Page 42: ...tion AIR CLEANER CASE COMP AIR CLEANER CASE PLATE SP GG1200 N 04 AIR CLEANER SEAL SP GG1200 N 05 AIR CLEANER ELEMENT SP GG1200 N 06 AIR CLEANER COVER COMP SP GG1200 N 07 FLAT SCREW M6 x 12 Part No GE9...

Page 43: ...GG 1200 O 13 SP GG1200 O 14 SP GG 1200 O 15 SP GG1200 O 16 FUEL TANK COMP FUEL TANK BRACKET FUEL TANK ASBESTOS FLANGE BOLT M6 12 TUBE CLIP qb9 FUEL TUBE _ 5 5 FUEL VALVE FUEL VALVE CLAMP FLAT SCREW M5...

Page 44: ...200 P 07 SP GG1200 P 08 SP GG1200 P 09 Description CONTROL PANEL COMP 120V RECEPTACLE Ru Ru 22 PILOT LAMP ENGINE SWITCH DC 12V OUTPUT CIRCUIT BREAKER 9A CIRCUIT BREAKER 10A PLAT SCREW M4 X 10 PLAT SCR...

Page 45: ...Q 12 SP GG 1200 Q 13 SP GG 1200 Q 14 SP GG 1200 Q 15 SP GG 1200 Q 16 SP GG 1200 Q 17 Part No FLANGE BOLT M6 12 FRONT FRAME COVER RECTIFIER COMP TAPPING SCREW ST4 2 18 FLAT SCREW M5 x 16 GG1200Q Q 01 G...

Page 46: ...n ENGINE PLATE REAR FRAME COVER SPARK PLUG SERVICE COVER MUFFLER EXHAUST PROTECTOR PLATE A MUFFLER EXHAUST PROTECTOR ASBESTOS A MUFFLER EXHAUST PROTECTOR PLATE B MUFFLER EXHAUST PROTECTOR ASBESTOS B M...

Page 47: ...OVE R GG 1200Q R 06 SP GG 1200 R 07 G EN ERATOR STAY GG 1200Q R 07 SP GG1200 R 08 SP GG1200 R 09 SP GG1200 R 10 SP GG1200 R 11 SP GG1200 R 12 SP GG1200 R 13 SP GG1200 R 14 SP GG1200 R 15 SP GG1200 R 1...