Steelcase Migration SE Height-Adjustable Desk and Bench User Manual Download Page 3

1.  Read all instructions before using  

this furnishing.

2.   Always unplug this furnishing from  

the electrical outlet before cleaning  

or servicing.

3.  Use this table only for its intended use as 

described in these instructions. Do not 

use attachments not recommended by 

the manufacturer.

4.  Never operate this table if it has a damaged 

cord or plug, if it is not working properly,  

or if it has been dropped or damaged.

5.  Keep the cord away from heated surfaces.

6.  Never drop or insert any object into  

any opening.

7.  Do not use outdoors.
8.  For tables not provided with work 

surfaces, if the obtained work surfaces are 

not installed according to the assembly 

instructions, it could cause the product 

to be unstable. Table may collapse and 

the electrical components may fail.

9.  For loading always put heavier items at 

the bottom and not near the top in order 

to help prevent the possibility of the 

furnishing tipping over.

To reduce the risk of burns, fire, electric shock,  

or injury to persons:

The desk or table shall be positioned near power socket  

and the plug shall be easily accessible. 
When using an electrical furnishing, basic precautions should 

always be followed, including the following:

POLARIZED PLUG INSTRUCTIONS:

 

To reduce the risk of electrical shock, 

some furnishings have a polarized plug 

(one blade is wider than the other) like the 

plug illustrated in 

Fig. 1

. This plug will fit 

in a polarized outlet only one way. If the 

plug does not fit fully in the outlet, reverse 

the plug. If it still does not fit, contact a 

qualified electrician to install the proper 

outlet. Do not change the plug in any way.

INSTRUCTIONS FOR DOUBLE 

INSULATED PRODUCTS:

  

No grounding means is provided on a 

double-insulated product. Nor is a means 

for grounding to be added to the product. 

The plug looks like the plug illustrated 

in 

Fig. 1

. A double insulated product is 

marked with the words “double insulation”, 

“double insulated”, or 

.

GROUNDING INSTRUCTIONS:  

Some products must be grounded. 

Connect these types of appliances to a 

properly grounded outlet in accordance 

with all local codes and ordinances.
For products sold in North America and 

other 120V regions: the product is for use 

on a nominal 120-V circuit. These products 

use a grounded plug that looks like the plug 

illustrated in sketch A in 

Fig. 2

. Make sure 

that the product is connected to an outlet 

having the same configuration as the plug. 

No adapter should be used with this product.

WARNING - RISK OF FIRE AND 

SHOCK, USE ONLY TYPE SJT 18  

AWG CORD

PLUG ILLUSTRATION DISCLAIMER:

 Illustrations shown here may not match your product. 

Depending on your region, the plug pin size and shape may change.

Grounding Pin

(sketch A)

Fig. 2 Grounding Methods

Fig. 1 Polarized Plug

Grounded 

Outlet

Grounded 

Outlet Box

Products with Polarized Plugs

Products with Grounded Plugs

Summary of Contents for Migration SE Height-Adjustable Desk and Bench

Page 1: ...Migration SE USER GUIDE Important safety information included Save and keep with desk Height Adjustable Desk and Bench ...

Page 2: ...t pulling cords trapping body parts or colliding with anything shelves electrical plugs and cords door knobs window sills storage cabinets etc DO NOT PLACE FEET OR OTHER BODY PARTS ON CABINETS OR OBJECTS BELOW DESKTOP X NO CHILDREN DO NOT STAND ON THIS PRODUCT USE ONLY AS INTENDED Regularly inspect for damage or broken parts and loose fasteners screws etc If any of these conditions exist remove fr...

Page 3: ... blade is wider than the other like the plug illustrated in Fig 1 This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way INSTRUCTIONS FOR DOUBLE INSULATED PRODUCTS No grounding means is provided on a double insulated pr...

Page 4: ...oller has seven buttons for user control Two of the buttons are the up and down buttons controlling the movement of the desk One of the buttons is the memory button which is used to set heights to be stored The remaining four buttons are memory position buttons The controller also has a digital display which displays the numerical height of the desk in inches or cm Press and hold either the up or ...

Page 5: ...shown on the display ERROR CODES In the event of a fault the digital display may show an error code Refer to the troubleshooting guide CABLE MANAGEMENT When installing equipment either on the worksurface or below be sure that the connecting cables are free from obstruction Clips and ties are provided to manage excess control box and base controller wires and can be attached to the underside of the...

Page 6: ...is fully plugged into the control box under the desk Check that the desk is not overloaded The weight load should be evenly distributed Synchronize the lifting columns as outlined on the next page POWER SAVING CONTROL BOX The control box automatically powers down into standby mode after 20 seconds of inactivity During standby mode the control box only consumes 0 2 watt of power With the control bo...

Page 7: ...ote When legs are not synchronized the desk will only move in the down direction at a slower speed Follow the steps below to synchronize the desk 1 Operate the desk all the way down to the lowest position and release the down button 2 Press the down button again and hold After a few seconds the desk will visibly move up and down settling to its correct bottom position The lifting columns are now s...

Page 8: ...f the worksurface 220 lbs 99 8 kg Wire Management Included Yes Controller Up Down Digital Preset Decibel Rating 55 dBA Volts 120V AC Frequency Phase 60 Hz Single Phase Amps 4A Watts 480W Standby Power 0 2W Adjustability Speed 1 3 sec 33 mm sec Duty Cycle 10 PRODUCT SPECIFICATION Weight of Worksurface 4 03 lb ft2 19 97 kg m2 or 0 028 lbs in2 0 019 g mm2 Rectangular tops weigh between 38 70 lbs 17 3...

Page 9: ...terference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet or a circuit different from that to which the receiver is ...

Page 10: ...Para descargar este documento en español visite www steelcase com migrationse userguide es Pour télécharger ce document en français visitez www steelcase com migrationse userguide fr ...

Page 11: ...Part Number 1323350001 Rev C 9 19 2019 All rights reserved All specifications subject to change without notice Printed in U S A Visit steelcase com ...