Steelcase 1465047001 Manual Download Page 4

Page 4 of 22

P/n 1465047001

Doc # 159081 Rev A

®

 

IMPORTANT SAFETY INSTRUCTIONS

GROUNDED
OUTLET

GROUNDED

OUTLET BOX

1. Always unplug this furnishing from the electrical outlet before cleaning.
2. Use this table only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. 
3. Never operate this table if it has a damaged cord or plug, if it is not working properly, or if it has been dropped or damaged.

4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8. For loading always put heavier items at the bottom and not near the top in order to help prevent the possibility of the furnishing tipping over.

The desk or table shall be installed near power socket & the plug shall be easily accessible. 

POLARIZED PLUG INSTRUCTIONS (Only for Products with Polarized Plug) -

To reduce the risk of electrical shock, some

furnishings have a polarized plug (one blade is wider than the other) like the plug illustrated in Figure 1. This plug will fit in a polarized 

outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet. Do not change the plug in any way.

GROUNDING INSTRUCTIONS (For Grounded Products only) -

 Some products must be grounded. Connect these types of appliances to a

properly grounded outlet in accordance with all local codes and ordinances.

GROUNDING PIN 

Figure 1

Polarized Plug

Figure 2

Grounding methods

PLUG ILLUSTRATION DISCLAIMER - Illustrations shown here may not match your product. Depending on your region, the plug pin size
and shape may change.

Please refer to the provided User Guide, which is also available at www.steelcase.com

OPERATING INSTRUCTIONS

Products with Grounded Plugs

Products with Polarized Plugs

9. Do not sit/stand on product.

10. Inspect regularly, stop using if damaged or loose parts found.

WARNING - Risk of electrical shock.

WARNING

To reduce the risk of burns, fire, electric shock or injury to persons:

PLEASE SAVE THESE INSTRUCTIONS, AND THE USER GUIDE, IN AN OBVIOUS PLACE FOR THE END USER AFTER ASSEMBLY.

When using an electrical furnishing, basic precautions should always be followed, including the following:

Read all instructions before using this furnishing. 

INSTRUCTIONS FOR DOUBLE INSULATED PRODUCTS:

No grounding means is provided on a double-insulated product. Nor

is a means for grounding to be added to the product. The plug looks like the plug illustrated in Figure 1. A double insulated

product is marked with the words “double insulation”, “double insulated” or     .

For products sold in North America and other 120V regions: the product is for use on a nominal 120-V circuit. These products use a

grounding plug that looks like the plug illustrated in sketch A in Figure 2. Make sure that the product is connected to an outlet having  
the same configuration as the plug. No adapter should be used with this product.

WARNING - Risk of fire and shock. Use only type SJT 18 AWG cord.

(sketch A)

Summary of Contents for 1465047001

Page 1: ...Height Adjustable Desk Page 1 of 22 P n 1465047001 Doc 159081 Rev A 2021 Steelcase Inc Grand Rapids MI 49501 U S A Printed in U S A 2x Directions Assembly INCLUDED Integrated Freestanding Phillips 2...

Page 2: ...Leg Installing Integrated Leg Wire Management Attachment Bracket Attachment Cable Tray Attachment Brace Attachment End Cap Attachment End Panel Alignment Suggested Thru Mount Grommet Monitor Arm Mode...

Page 3: ...and nearby objects to allow movement of desktop through full range without pulling cords trapping body parts or colliding with anything shelves electrical plugs and cords door knobs window sills stor...

Page 4: ...es of appliances to a properly grounded outlet in accordance with all local codes and ordinances GROUNDING PIN Figure 1 Polarized Plug Figure 2 Grounding methods PLUG ILLUSTRATION DISCLAIMER Illustrat...

Page 5: ...eous Boat Brace 1455351001 or 145535002 Work Surface Assembly Work Surface Freestanding 145540902X or 145443501X Work Surface Integrated 145540901X or 145443401X Leg Assembly Shrouded Leg Assembly 145...

Page 6: ...d to gage the shroud position on the worksurface Then secure with 2 screws as shown Installing Slim Leg 6x M6x12mm Top View Top View Gage Tool Front Edge Side Edge Back Edge 10 X 1 SCREWS 1 2 Start wi...

Page 7: ...upside down screw Upper Shroud and Column to Worksurface 3 2X 4X Slide Lower Shroud around column through hole and bolt at the bottom in four locations Prevent scratching 3 20x 10x1 4x M6x25 Page 7 o...

Page 8: ...Installing Integrated Leg 4 Attach Foot and Glide assembly with 4 bolts 6x M6x12 2a 2b 4 1c 1b 1a 1b Prevent scratching 14x 10x1 4x M6x25 Page 8 of 22 P n 1465047001 Doc 159081 Rev A...

Page 9: ...Filter Controller Lifting Column 2 Lifting Column 1 Motor Cable Motor Cable Contoller Sensor Power Wire Management Attachment 10 12 X 2 SCREWS 6 X 1 5 SCREWS 5 1a 1b 1c Page 9 of 22 P n 1465047001 Doc...

Page 10: ...wire cover bracket Bracket Attachment 6 CABLE MANAGEMENT CLIPS TIP Cable clips provided for installer to apply where necessary outside of cable tray Prevent sensor damage 10x 10x1 3x 5x5 8 Page 10 of...

Page 11: ...Cable Tray Attachment 1a 135 o 2x 1b 7 Page 11 of 22 P n 1465047001 Doc 159081 Rev A...

Page 12: ...Brace Attachment Attach Brace 8 CENTER 16mm 14x 10x1 Use all provided screws for brace Screw amount is dependent on brace size Page 12 of 22 P n 1465047001 Doc 159081 Rev A...

Page 13: ...End Cap Attachment 9 INTEGRATED TABLE ONLY 4x 10x1 Page 13 of 22 P n 1465047001 Doc 159081 Rev A...

Page 14: ...Page 14 of 22 P n 1465047001 Doc 159081 Rev A 2x...

Page 15: ...End Panel Alignment 10 Page 15 of 22 P n 1465047001 Doc 159081 Rev A...

Page 16: ...End Panel Attachment Page 16 of 22 P n 1465047001 Doc 159081 Rev A 10a 10b...

Page 17: ...1 Doc 159081 Rev A 38 10 mm 1 5 158 75 mm 6 25 101 6 mm 4 Grommet thru mount uses same space for both freestanding and integrated tables 101 6 mm 4 115 mm 4 5 28 Plan Depth Plan Depth 100 29 Plan Dept...

Page 18: ...Modesty Panel Attachment 11 6x 10x1 Page 18 of 22 P n 1465047001 Doc 159081 Rev A...

Page 19: ...12 Modesty Panel Attachment 8x 10x1 NOTE Installation is the same for Freestanding Integrated tables Page 19 of 22 P n 1465047001 Doc 159081 Rev A...

Page 20: ...Case Installation 2x 13 Case is built seperately Not part of Slim HAD UL 962 Listing Refer to case installation document 133317 Page 20 of 22 P n 1465047001 Doc 159081 Rev A...

Page 21: ...Case Installation Page 21 of 22 P n 1465047001 Doc 159081 Rev A...

Page 22: ...Magnetic Cable Tray Page 22 of 22 P n 1465047001 Doc 159081 Rev A Not part of Slim HAD UL 962 Listing...

Reviews: