4
COUNTERWEIGHTS
(5 USED)
3
5
Page 5 of 6
939500395 Rev E
NOTE: 1.5 -Hi cases with a 12” file drawer
require the same counterweight packages
for Universal and Bases with Feet.
Case Ht. Size
Base
Case Config. CW Pkg.
18 x 30 Univ., F1, or c:scape
D/D or O/D
A
18 x 36 Univ., F1, or c:scape
D/D or O/D
B
18 x 42 Univ., F1, or c:scape
D/D or O/D
C
24 x 30 Univ., F1, or c:scape
D/D or O/D
A
24 x 36 Univ., F1, or c:scape
D/D or O/D
B
18 x 30 Univ., F1, or c:scape
D/O
D
18 x 36 Univ., F1, or c:scape
D/O
E
18 x 42 Univ., F1, or c:scape
D/O
F
24 x 30 Univ., F1, or c:scape
D/O
D
24 x 36 Univ., F1 or c:scape
D/O
E
1.5H
Univ. = Universal
D = Drawer
F1 = FrameOne Feet
O = Open
c:scape = c:scape glides
3.
Rotate case assembly onto its back.
4.
Lay the five (5) counterweight plates in the
back of the case assembly.
5.
Place the counterweight cover over the
counterweight plates and secure with two (2)
#8 x 3/8” self-drilling screws.
NOTE:
If the case will be attached to a panel via a
storage to panel bracket, the counterweight will need
to be installed slightly off center in 30” & 36” wide
cases (approx. 1/8” for 30” cases and 1/16” for 36”
wide cases) to prevent interference with the storage
to panel bracket hex nuts. For all other applications,
center the counterweight in the back of the case.
6.
Rotate case assembly back onto its glides.
7.
Re-install suspensions removed in Step 2.