Steel
King
Industries,
Inc
I
‐
Beam
Cantilever
Installation
Guide
8
D.
For
non
‐
seismic
applications,
anchor
the
upright
and
base
assemblies
to
the
slab
‐
on
‐
grade
per
the
following
configurations
using
¾”
diameter
x
5½”
long
anchor
bolts.
The
recommended
installation
torque
for
theses
anchor
bolts
is
150
foot
‐
pounds.
Anchor
holes
are
to
be
vacuumed
out
before
inserting
the
anchor
bolts.
Proper
Anchor
Configurations
For
Single
and
Double
Sided
I
‐
Beam
Cantilever
Racks
Single
Sided,
I
‐
Beam
Cantilever
Anchor
Configuration
–
Top
View
Double
Sided
I
‐
Beam
Cantilever
Anchor
Configuration
–
Top
View
Step
#7:
Clean
up:
A.
Vacuum
all
dust
and
debris
associated
with
setting
anchors.
B.
Dispose
of
all
dunnage,
strapping
and
debris.
Sweep
the
floor
with
a
broom
if
necessary.
If
you
have
any
further
questions,
contact
your
local
Steel
King
Representative
for
customer
assistance
or
contact
Steel
King
Industries
directly
at
(800)
826
‐
0203.