24
754.923 | Z02 | 15.51
EN
6
Care, maintenance and service
The inverter is maintenance-free. If functional faults occur, please consult your
dealer and present the payment receipt / invoice.
X
Before cleaning the inverter, switch off all consumer devices and switch off
the inverter via the rotary switch.
X
Regularly clean the outside of the case with a damp cloth. Do not use
solvents.
X
Ensure that the ventilation slots on the upper and lower sides of the device
are not obstructed and that the air can freely circulate. If necessary, remove
dust by vacuuming.
7 Technical
data
7.1 Device
data
500-12
550-24
1100-24
1500-48
Inverter type
PI 500-12
PI 550-24
PI 1100-24
PI 1500-48
Characterisation of the operating performance
System voltage
12 V
24 V
24 V
48 V
Continuous power
450 VA
450 VA
900 VA
900 VA
Power 30 min.
500 VA
550 VA
1,100 VA
1,500 VA
Power 5 sec.
500 VA
1,000 VA
1,400 VA
2,800 VA
Max. efficiency
93 %
94 %
Own consumption standby / ON
0.5 W / 6 W
0.7 W / 10 W
DC input side
Battery voltage
10.5 V ... 16 V
21 V ... 32 V
21 V ... 32 V
42 V ... 64 V
Reconnection voltage (LVR)
12.5 V
25 V
25 V
50 V
Deep discharge protection (LVD)
1
10.5 V
21 V
21 V
42 V
AC output side
Output voltage
230 V AC +/- 10 % (model -L60: 115 V AC +/- 10 %)
Output frequency
50 Hz (model -60 and -L60: 60 Hz)
Load detection (standby)
adjustable: 2 W ... 50 W
Safety
Safety class
II (double insulated)
Electrical protection
reverse polarity battery, reverse polarity AC, over voltage, over current, over temperature
Operating conditions
Operating temperature
0 °C … +50 °C
Storage temperature
-20 °C … +70 °C
Rel. humidity
< 95 %, non-condensing
Maximum altitude
2000 m above sea level
Fitting and construction
Cable length battery / AC
1.5 m / 1.5 m
Cable cross-section battery / AC
16 mm
2
/ 1.5 mm
2
Degree of protection
IP 20
Dimensions (X x Y x Z)
212 x 395 x 130 mm
2)
Weight
6.6 kg
2)
9 kg
2)
1)
adjustable via charge controller with compatible parallel switch box
Technical data at 25 °C / 77 °F
2)
per inverter