SteamSpa 10.5KW User Manual Download Page 20

SteamSpa

 

PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com [email protected]

Page 20

INST

ALLA

TION & USER GUIDE

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSES

SOLUTIONS

The machine does not start when 

powered

1.  Burned out fused

2.  The electrical wiring became loose

3.  Control panel connection loose

1.  Replace fuse (0.8A/240V)

2.  Cut power Supply and reconnect 

wiring

3.  Reconnect control panel and reset 

4.  Controller (turn off and on)

 Breakers are tripping

1.  The wire connector is dampened or 

damaged

2.  Damaged heating element

1.  Check whether the wire connector 

is dampened or damaged, and dry if 

dampened

2.  Replace heating element

When the machine is started, hot water 

comes out with little or no steam

1.  Bad water drainage valve

1.  Replace water drainage valve

The display screen on the control panel 

does not display anything

1.  The control panel wire is not 

connected properly

2.  Trouble  with  generator 

motherboard

1.  Check whether the connection plug 

between the control panel and the 

generator has become loose, and 

whether the power circuitry has 

good contact

2.  Replace the motherboard

Water leakage

1.  The water pipe connector becomes 

loose or pipe is broken.

2.  Water leakage in the water input 

valve or the water drainage valve

1.  Tighten the loose connection or 

change the broken pipe

2.  Change the water input valve or the 

water drainage valve

No steam when starting the machine

1.  No electricity

2.  No water

3.  The set temperature is too low

4.  Wiring connection problem

1.  Check the power supply and 

connections

2.  Check the water input pipe and water 

input valve

3.  Reset the temperature

4.  Check wiring connection and tighten

The steam does not come out, the water 

sounds in the machine

1.  Possible steam pipe blockage

1.  Cut power supply and check 

blockage in steam pipe 

Light doesn’t turn on

1.  Bad LED light bulb

2.  Wiring connection improperly 

connected or light cable damage

1.  Change LED light bulb

2.  Tighten connection or replace light 

cable 

Summary of Contents for 10.5KW

Page 1: ...GUIDE 4 5KW 6KW 7 5KW 9KW 10 5KW 12KW 15KW MODELS Steam Spa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com W HIS P E R QUI E T B U I L T IN A UTO D R A I N C O N TIN U O U S ST E A M Q UIC K S TAR T ...

Page 2: ...Steam Spa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com ...

Page 3: ...RATOR 4 PLUMBINGINSTALLATION 6 STEAM GENERATORSPECIFICATIONS 8 ELECTRICALREQUIREMENTS 9 ASSEMBLYGRAPH FORPOWERWIRE 10 INSTALLATIONOFTHE TOP LIGHT 12 STEAM GENERATORDISSECTIONDIAGRAM 13 CARE USEFORTHE CONTROL PANEL 14 CONTROLLERBOXCONTENT 14 CONTROLPANELINSTALLATIONINSTRUCTIONS 15 TESTINGTHEMACHINE 16 CONTROLPANELDIAGRAM 16 CONTROLPANELOPERATION 17 STEAM GENERATORMAINTENANCE 18 TECHNICALPARAMETERS ...

Page 4: ...ofdelivery 3 Read installation instructionsindetailforasecureandeffectiveinstallationofSteamSpagenerators 4 SteamSparecommendstheuseofalicensedplumberandelectricianforproperinstallationofSteamSpagenerators 5 SteamSpashallnotberesponsibleforproductdamageormalfunctioncausedbyself installationorinstallation procedures which do not complywithusermanual 6 SteamSpageneratorsareforindooruseonly CHOOSINGT...

Page 5: ...designofsteam room pleaseconsult withaqualified designer architect or builder Dual Steam Outlet for 10 5kw 12kw 15kw Single Steam Outlet Control Panel AROMA TRAY RESERVOIR Supply Pressure Relief Valve Steam Generator Water Inlet 3 8 stainless steel braided flex hose Water Drain Valve 12 12 SAFETY VALVE WATER INLET PIPE WATER DRAINAGE 3 8 STAINLESS STEEL BRAIDED FLEX HOSE 1 2 CONNECTION WATERLINE S...

Page 6: ...NTION Theillustrationisjustanexample thepracticalinstallationmustcomplywiththenation selectricalcriteria andbe done byaprofessionalelectrician Control Panel outside room Control Panel inside room Control Panel inside room The steam outlet The spare place under the wash pan possible location The steam generator Light ...

Page 7: ...pperpipeasthesteampipebetweenthesteamgeneratorandthesteamnozzle 3 Theheat insulationmaterialusedtoinsulatethesteampipeshouldberesistanttotemperaturesashighas250 Forhigher 4 Theshorter thedistance thebetter Trytodecreasethenumberofelbowstopreventcreatingvalleysortraps STEAM HEAD 3 4 ATTENTION Steam Headandthesteamoutletgetveryhot trytoavoidinstallingthesteamheadinapositionwhichwilleasily comeinto c...

Page 8: ...not connectthesafetyvalveorsteamlinetodrainline SAFETYVALVE 3 4 1 Safetyvalveisanautomaticsystemthatisactuatedbypressureinordertopreventsteampressureincreasingintheinterior ofthegenerator 2 Thepressurelimitrangeofthesafetyvalveis15PSIandthepressurewillbegintodecreaseifpressureshouldcomeoverthis value 3 Ifit isallowed bylocalcodes providethesafetyvalvewithexteriordrainpipe 4 Donot dismantlethepress...

Page 9: ...age 206mm 188mm 151mm 32mm 43mm 142mm 266mm 302mm 395mm Fuse for wire power supply Power wire hole C ontr olle r w ir e and light wire hole 304mm 400mm 160m m 100m m 30mm 30mm 1 8 0 mm 2 6 0m m 3 7 0 mm Steam outlet S a f e t y valve Water inlet Water drainage Fuse for wire power supply Power wire hole C o n tro ller wire an d lig h t wir e hole Fuse for wire power supply Fuse for wire power suppl...

Page 10: ...mgenerator 2 Insulated copper wireshouldbeusedwithananti heattemperatureof90Candaspecifiedvoltageof300V Refertonational orlocalelectricityconsumptioncodeforthespecifications Refertotheammeterfortheampere 3 Connect suitablysizedequipment groundingwireintothegroundterminal 4 All theconnectionsmustbeinaccordancewithnationalandlocalelectricityconsumptioncodesandbeinstalledby professional electricians ...

Page 11: ...otconnectelectriccurrentdirectlytoheatingelements WARNING Thisgraphisforexplanationonly Foractualinstallation refertonationaland localelectricityconsumptioncodesby professional electricians Ampere Meter Ty p e Power KW S600 S750 6 7 5 9 240V 240V 240V 25 32 38 10 8 8 150 225 300 Applicable space of the room cu Ft El e c t r i c i t y supply 1PH E l e c t r i c current A Specifications for power wi...

Page 12: ...ter valve Drai n water valve Term inal B lock J1 1 J2 1 J3 1 J3 2 J2 2 J1 2 J1 J2 J3 S S G Yellow Green R ed B lack Red Black White Black Yellow R ed B lack Red Red Red Red Su p p ly R ed B lack Red Black L1 L2 Water Level Sensor Red S h o r t P i n Bl ack Lo n g P i n Yel l o w Mi d d l e P i n Red Red Red S750 S900 Red Red Black Black Black Black Black Blac k Red Black J1 1 J1 2 J1 S S L1 G S450...

Page 13: ... C ontrol P anel Fill water valve Drain water valve Term inal B lock J1 1 J2 1 J2 2 J1 2 J1 J2 S S G Yellow Green R ed B lack Re d Black White Bla c k Yellow R ed B lack Red Red Red Red Su p p ly R ed B lack Black L1 Water Level Sensor Red S h o r t P i n Bl ack Lo n g P i n Yel l o w Mi d d l e P i n S1200 L2 Red Black Red Red Black Black Red S1050 To C ontrol P anel Fill water valve Drain water ...

Page 14: ...IONDIAGRAM 1 2 3 4 6 5 7 13 14 12 9 11 8 10 15 17 16 1 ENCLOSURE 2 INSULATIONBRACKET 3 CIRCUITBOARD 4 STEAMOUTLET 5 PRESSURERELIEF VALVE 6 WATERFILLVALVE 7 WATERDRAINVALVE 8 SUBSIDIARYWATERTANK 9 MAINWATERTANK 10 HEATINGELEMENT 11 221FHI LIMIT 12 TRANSFORMER 13 TERMINALBLOCK 14 FUSE 15 GROUNDWIRECONNECTOR 16 RELAY 17 WATERLEVELSENSOR ...

Page 15: ...r inoperativeinstallation SingleControl PanelwithTemperaturesensormustbeinstalledinsidebathingarea5feetabovefloor Donotinstall Control directlyaboveSteam Headorbelowshowerheadbutratherintheseatingareaonaverticalwall Doingsomayresultinimproper temperaturereading and orinoperablecontrol DualControl PanelwithTemperaturesensorinMasterControlmustbeinstalledinsidebathingarea5feetabovefloor Donot install...

Page 16: ...esteamgeneratorandconnectwith thecorresponding wireinthegenerator Connectingthewireofcontrol paneloutsideroom tothewireofcontrolpanel insidetheroom When connecting wirespleasefollowarrowsonconnectorheadsforproper connection Failureto dosowillresultindamagingofcontrol pins STEPFOUR Startthepower supplyofsteamgenerator checkandadjustconnection checkeach item on thepagetomakesureallfunctionsworkwell ...

Page 17: ...y Astimegoeson thetemperaturedisplayedinthecontrolpanelwillrise withthe temperaturein theroombeforeitstopsandstaysatthesettemperature 5 Based on differentrequirementsoftheuserfortemperatureandsteamtime thecontrolpanelcanadjusttemperatureand steam time Whiletestingthemachine setthetimetobe30minutesandthetemperaturetobe120F 6 When theset steamtimeisdue thesystemwillshutoffthesteamandlightfunctionaut...

Page 18: ...illdisplaycurrentroomtemperaturenormally Whenthesystem ison press buttontoturnoffthesystem orwhenthesteamtimeisover thesystem shutsoff 10minutesafterthesystemisshutoff thedrainagefunctionwillbestarted automaticallyfor 7 minutes TIMEANDTEMPERATURE SETTING Whensystem ison pressbuttontwice systemwillcycleswitchintimesetting TEMPsetting andambient TEMP displaystate Fig 4 Whenthedigitaltubedisplaysdash...

Page 19: ...argedcompletelybeforecuttingoffpowersupply 2 Thereshould not beanyleakageordamageamongthesteamgenerator steamnozzle componentsandpipes Theyshould be checked and repairedannually 3 Clean thewater supplypipesofthesteamgeneratoronceayear 4 Checkallthefaucetconnections toensurewethertheyaretightandnotdamagedduetooverheat 5 Checkthesedimentsaccumulatedinthewatertankandelectricheatingtube Ifthesedimenti...

Page 20: ...not connectedproperly 2 Trouble with generator motherboard 1 Checkwhethertheconnectionplug betweenthecontrolpanelandthe generatorhasbecome loose and whetherthepowercircuitryhas goodcontact 2 Replacethemotherboard Water leakage 1 Thewaterpipeconnectorbecomes looseorpipeisbroken 2 Waterleakageinthewaterinput valveorthewaterdrainagevalve 1 Tightenthelooseconnectionor changethebrokenpipe 2 Changethewa...

Page 21: ... 12V 3W 12V 3W TemperatureRange F 50 130 50 130 50 130 50 130 50 130 50 130 50 130 TimeSet Range min 1 60 1 60 1 60 1 60 1 60 1 60 1 60 SteamPress psi 3 4 4 4 5 5 5 SteamVol cu in min 9 11 13 16 19 21 25 SteamSprayTime sec 100 180 180 240 150 210 120 180 170 230 150 160 120 150 Water Vol cu in 80 160 160 160 330 330 330 ApplicableSpaceof the Room cu ft 90 150 225 300 400 450 500 IMPORTANT Thelist ...

Page 22: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 22 INSTALLATION USER GUIDE WIRINGDIAGRAMS 4 5KW Control panel outside room Control panel inside room 240V ...

Page 23: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 23 INSTALLATION USER GUIDE 6KW Control panel outside room Control panel inside room 240V ...

Page 24: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 24 INSTALLATION USER GUIDE 7 5KW 9KW Control panel outside room Control panel inside room 240V ...

Page 25: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 25 INSTALLATION USER GUIDE 10 5KW 12KW Control panel outside room Control panel inside room 240V ...

Page 26: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 26 INSTALLATION USER GUIDE 15KW Control panel outside room Control panel inside room 240V ...

Page 27: ... thesteam willcomeoutnormally Astimegoeson thetemperaturedisplayedinthecontrolpanelwillrise withthe temperaturein theroombeforeitstopsandstaysatthesettemperature 5 Based on differentrequirementsoftheuserfortemperatureandsteamtime thecontrolpanelcanadjusttemperatureand steam time Whiletestingthemachine setthetimetobe30minutesandthetemperaturetobe120F 6 When theset steamtimeisdue thesystemwillshutof...

Page 28: ...workagain thedigitaltubewilldisplaycurrentroomtemperaturenormally Whenthesystem ison press buttontoturnoffthesystem orwhenthesteamtimeisover thesystem shutsoff 10minutesafterthesystemisshutoff thedrainagefunctionwillbestarted automaticallyfor 7 minutes TIMEANDTEMPERATURE SETTING Whensystem ison pressbuttontwice systemwillcycleswitchintimesetting TEMPsetting andambient TEMP displaystate Whenthedigi...

Reviews: