O P E R A T I O N & S E R V I C E
Service
Risk of burnt, flooding or malfunction.
Make sure that cylinder is empty from water before to open the release latch.
Risk of electric shock
.
Disconnect power supply before to service.
General guidelines for service
When service is due,
steamOres
will stop producing steam and will call for service : status LED is
orange
1. Order a drain for service by touching the ‘’drain for service ‘’ button,
2. Cylinder will be automatically drained and cooled by filling with fresh water at least two times,
until water temperature sensor inside cylinder is measuring a temperature below 140°F [60°C].
3. When status LED is turning
white
, it is safe to open front cover and to proceed to service.
Disconnect from power supply before to open front cover.
4. Confirm that the cylinder temperature is not too hot by touching it quickly with the back of
your hand or fingers.
5. Confirm that cylinder has been fully drained by looking if there is water in transparent hose
located at left side of cylinder.
Release latch
Transparent hose
showing water level
in cylinder
Fill & Drain hose
connector
(release button)
Drain pump
Fill valve
Steam outlet
Safety pin
Figure 16 – steamOres steam cylinder and key components
Summary of Contents for RES Series