Operating Instructions

Additional Features

Operation: 

Make sure the water and power are turned on.  

Simply press USER 1 or USER  2 button to begin the cycle. 

Press the Stop button will end the cycle. After a cycle is started 

it will take a few minutes for the Steam Generator to heat up 

and begin producing steam. This time will be less if the 

InstaMist has been ON. During operation the display will show 

the ambient temperature.To view the remaining cycle time, 

press the Menu button. 

Programming:

 Adjustments can be made to temperature and 

cycle time, while a cycle is started. When the temperature is 

displayed, the set temperature can be viewed or changed by 

momentarily pressing the up or down button. Temperature 

adjustments made when USER 1 cycle is started will be saved 

to USER 1 and likewise for USER 2. All changes made to the 

temperature control are stored in memory until changed again. 

The temperature range is 60°F to 125°F (16°C to 52°C). While 

a cycle is running, pressing the Menu button will show the 

remaining cycle time and this can be adjusted with the up or 

down buttons. This time adjustment is only for remaining time 

of the current steam bath cycle. 

Default Time Setting

: The default time is programmed when 

the cycle is off using the Menu button. Any adjustments made 

to time, when the cycle is off are stored as the new default time 

for both users.  

InstaMist Setting:

 The InstaMist feature can be turned on or 

off when the steam cycle is in the off mode. To adjust this 

setting, press the Menu button until you see the Water Icon, 

press the Up or Down button to change this setting. Display 

“On” or “OF” will appear. InstaMist keeps the steam generator 

warm, for a faster heat up and is ONLY available on the TSG 

model steam generators. 

(InstaMist function is not available on 

the “SMP” models)

 

Fahrenheit or Celsius setting

: To change this setting, while 

the steam cycle is off, press the Menu button until you see an 

“F” or “C” in the display. Use the up or down button to change 

the displayed letter, to correspond to your temperature choice. 

Press the Stop button to exit the Menu mode. Your last setting 

will be saved. 

 

Memory: 

The temperature set points for USER 1, USER 2, the 

default time, and the selection of InstaMist and other settings 

are retained even if there is a power failure.

Service Mode: 

To enter the service mode press and hold the 

Menu button for 5 seconds, until a blue dot lights up in the 

display. The control is now in the service mode. There are two 

features in the service mode. Pressing the Up arrow displays 

the program version, pressing the down arrow, restores to 

factory default.
 

03/17

Pub. No. 271-E

- 3 -

Installation & Operating Instructions

Error Messages: 

This control is programmed with a diagnos-

tic feature to help isolate any potential problems. Errors are 

displayed by flashing an “Er” followed by a 2 digit number. The 

first digit is the device number. Zero for the control and 1-4 for 

the generators. The second digit is the error code for that 

device. Error messages “Er 01”, “Er 02”, and “Er 04” indicate a 

problem internal to the control.  If this occurs, the control 

should be replaced.  Error messages “Er 03” means the 

control could not communicate with a steam generator and 

may be a cable connection problem. If this error occurs, check 

both ends of the control cable for clean, dry and secure 

connections.  Dirty contacts can be cleaned with alcohol and a 

cotton swab or a toothbrush.  This can also happen if the 

control is not sealed and the cable connections get wet. Also 

make sure the generator is not in test mode. Try resetting the 

breaker. Generator error codes are not covered in this 

document. 

NOTE:

 The TSC-250 and TSC-250R controls operate and install the same way, only difference between them is the physical shape.