Operating Instructions
Additional Features
Operation:
Make sure the water and power are turned on.
Simply press USER 1 or USER 2 button to begin the cycle.
Press the Stop button will end the cycle. After a cycle is started
it will take a few minutes for the Steam Generator to heat up
and begin producing steam. This time will be less if the
InstaMist has been ON. During operation the display will show
the ambient temperature.To view the remaining cycle time,
press the Menu button.
Programming:
Adjustments can be made to temperature and
cycle time, while a cycle is started. When the temperature is
displayed, the set temperature can be viewed or changed by
momentarily pressing the up or down button. Temperature
adjustments made when USER 1 cycle is started will be saved
to USER 1 and likewise for USER 2. All changes made to the
temperature control are stored in memory until changed again.
The temperature range is 60°F to 125°F (16°C to 52°C). While
a cycle is running, pressing the Menu button will show the
remaining cycle time and this can be adjusted with the up or
down buttons. This time adjustment is only for remaining time
of the current steam bath cycle.
Default Time Setting
: The default time is programmed when
the cycle is off using the Menu button. Any adjustments made
to time, when the cycle is off are stored as the new default time
for both users.
InstaMist Setting:
The InstaMist feature can be turned on or
off when the steam cycle is in the off mode. To adjust this
setting, press the Menu button until you see the Water Icon,
press the Up or Down button to change this setting. Display
“On” or “OF” will appear. InstaMist keeps the steam generator
warm, for a faster heat up and is ONLY available on the TSG
model steam generators.
(InstaMist function is not available on
the “SMP” models)
Fahrenheit or Celsius setting
: To change this setting, while
the steam cycle is off, press the Menu button until you see an
“F” or “C” in the display. Use the up or down button to change
the displayed letter, to correspond to your temperature choice.
Press the Stop button to exit the Menu mode. Your last setting
will be saved.
Memory:
The temperature set points for USER 1, USER 2, the
default time, and the selection of InstaMist and other settings
are retained even if there is a power failure.
Service Mode:
To enter the service mode press and hold the
Menu button for 5 seconds, until a blue dot lights up in the
display. The control is now in the service mode. There are two
features in the service mode. Pressing the Up arrow displays
the program version, pressing the down arrow, restores to
factory default.
03/17
Pub. No. 271-E
- 3 -
Installation & Operating Instructions
Error Messages:
This control is programmed with a diagnos-
tic feature to help isolate any potential problems. Errors are
displayed by flashing an “Er” followed by a 2 digit number. The
first digit is the device number. Zero for the control and 1-4 for
the generators. The second digit is the error code for that
device. Error messages “Er 01”, “Er 02”, and “Er 04” indicate a
problem internal to the control. If this occurs, the control
should be replaced. Error messages “Er 03” means the
control could not communicate with a steam generator and
may be a cable connection problem. If this error occurs, check
both ends of the control cable for clean, dry and secure
connections. Dirty contacts can be cleaned with alcohol and a
cotton swab or a toothbrush. This can also happen if the
control is not sealed and the cable connections get wet. Also
make sure the generator is not in test mode. Try resetting the
breaker. Generator error codes are not covered in this
document.
NOTE:
The TSC-250 and TSC-250R controls operate and install the same way, only difference between them is the physical shape.