Steamhead Installation
Steamhead should be mounted
18" above the finished floor or
6" above the rim of the tub as
far from the bather as possible
SMC-150 must be mounted
inside the steamroom. Locate
away from the direct line of
shower spray and do NOT
locate above steamhead.
All Instructions must be given to the homeowner for future use.
®
Modular Jack
Knockouts for
Strain Relief
Clamps
Printed
Circuit Board
Multi-Conductor
Control Cable
(25 feet)
¾" Conduit
To Control
Telco Splitter for use
when installing an
auxilary control.
Supplied with
SMC-120
START
STOP
®
SMC-120
Auxilary Outside
Control
TEMPERATURE
START
STOP
®
SM Series
Steam Generator
01/12
Pub. No. 122-E
- 2 -
IMPORTANT: The adhesive on the back of the SMC-150 control will NOT
seal this control. It is the responsibility of the installer to seal this control to
the wall with the supplied silicone. Water damage to the control is not
covered by the warranty.
Figure 4 - Installation Suggestions
Operating Instructions
Additional Features
Operation: Make sure the water and power are turned on.
Simply press the Start/Stop keypad to begin the previously
programmed cycle. Pressing the Start/Stop keypad a second
time will cancel the cycle. After a cycle is started it will take a
few minutes for the Steam Generator to heat up and begin
producing steam. During operation the display will show the
ambient temperature. The heat icon will cycle on and off as the
temperature is maintained.
Programming: Adjustments can be made to the temperature
control while the system is on or off. Any time the temperature is
displayed, it can be adjusted by simply pressing the Up or Down
keypad. All changes made to the temperature control are stored
in memory until changed again. The temperature range is 50°F
to 130°F (10°C to 55°C).
Figure 2
Figure 3
Installation & Operating Instructions
Memory: The temperature setpoint is retained
even if there is a power failure.
Fahrenheit/Celsius: The temperature display
may be changed to Fahrenheit or Celsius by
simultaneously pressing and holding the Up and
Down keypad for 5 seconds while the system is
off. The display will show the current setting “F”
or “C” and then alternate when the change is
complete.
Error Messages: This control is programmed
with a diagnostic feature to help isolate any
potential problems. Error messages E0, E1, E2
and E3 indicate a problem internal to the control.
If this occurs, the control should be repaired or
replaced. Error messages E4, E5 and E6
indicate a communication problem with the
steam generator. If this error occurs, check both
ends of the control cable for clean, dry and
secure connections. Dirty contacts can be
cleaned with alcohol and a cotton swab or a
toothbrush. This can also happen if the control
is not sealed and the cable connections get wet.
Operating Instructions
Model: SMC-150
labeled “Remove Before Installation”. Remove protec-
tive cap from cable and plug into jack. Check that the
orientation of the plug properly aligns with the jack. A
snap will indicate the plug is installed correctly (see
Figure 3).
WARNING: Test the control for operation before
continuing on to the next step.
g) Peel adhesive liner from back of the control. Apply
the control to the wall. Press firmly and hold for a
few seconds.
h) After the control is in place, apply silicone (supplied)
around the control to form a watertight seal.
SM Series
Steam Generator