Steamhead Installation

 

Steamhead should be mounted 

18" above the finished floor or 

6" above the rim of the tub as 

far from the bather as possible

SMC-150 must be mounted 

inside the steamroom. Locate 

away from the direct line of 

shower spray and do NOT 

locate above steamhead.

All Instructions must be given to the homeowner for future use.

®

Modular Jack

Knockouts for

Strain Relief

Clamps

Printed

Circuit Board

Multi-Conductor

Control Cable

(25 feet)

¾" Conduit

To Control

Telco Splitter for use 
when installing an 
auxilary control. 
Supplied with 
SMC-120

START

STOP

®

SMC-120

Auxilary Outside 

Control 

TEMPERATURE

START

STOP

®

SM Series 
Steam Generator

01/12

Pub. No. 122-E

- 2 -

IMPORTANT: The adhesive on the back of the SMC-150 control will NOT 
seal this control. It is the responsibility of the installer to seal this control to 
the wall with the supplied silicone. Water damage to the control is not 
covered by the warranty.

Figure 4  - Installation Suggestions

Operating Instructions

Additional Features

Operation: Make sure the water and power are turned on.  
Simply press the Start/Stop keypad to begin the previously 
programmed cycle. Pressing the Start/Stop keypad a second 
time will cancel the cycle. After a cycle is started it will take a 
few minutes for the Steam Generator to heat up and begin 
producing steam. During operation the display will show the 
ambient temperature. The heat icon will cycle on and off as the 
temperature is maintained.

Programming: Adjustments can be made to the temperature 
control while the system is on or off. Any time the temperature is 
displayed, it can be adjusted by simply pressing the Up or Down 
keypad. All changes made to the temperature control are stored 
in memory until changed again. The temperature range is 50°F 
to 130°F (10°C to 55°C).

Figure 2

Figure 3 

Installation & Operating Instructions

Memory: The temperature setpoint is retained 
even if there is a power failure.

Fahrenheit/Celsius: The temperature display 
may be changed to Fahrenheit or Celsius by 
simultaneously pressing and holding the Up and 
Down keypad for 5 seconds while the system is 
off. The display will show the current setting “F” 
or “C” and then alternate when the change is 
complete.

Error Messages: This control is programmed 
with a diagnostic feature to help isolate any 
potential problems.  Error messages E0, E1, E2 
and E3 indicate a problem internal to the control.  
If this occurs, the control should be repaired or 
replaced.  Error messages E4, E5 and E6 
indicate a communication problem with the 
steam generator.  If this error occurs, check both 
ends of the control cable for clean, dry and 
secure connections.  Dirty contacts can be 
cleaned with alcohol and a cotton swab or a 
toothbrush.  This can also happen if the control 
is not sealed and the cable connections get wet.

Operating Instructions

Model: SMC-150

labeled “Remove Before Installation”. Remove protec-
tive cap from cable and plug into jack. Check that the 
orientation of the plug properly aligns with the jack. A 
snap will indicate the plug is installed correctly (see 
Figure 3).

    WARNING: Test the control for operation before 

continuing on to the next step.

g) Peel adhesive liner from back of the control. Apply      

the control to the wall. Press firmly and hold for a        
few seconds. 

h) After the control is in place, apply silicone (supplied) 

around the control to form a watertight seal.