61
www.steamax.com
STEAMAX REULEAUX RX200S – ERROR MESSAGES & PROTECTIONS
Over 10 Second Protection
Device too hot
Low Atomizer Protection
Atomizer Protection & No Atomizer
Temperature Protection
If you hold the fire button longer than 10 seconds, the device switches itself off automatically. “
OVER 10S PROTECT
” will appear on the display.
When the temperature of the device becomes too hot, the power turns off and the display will read “
DEVICE TOO HO
T”. You will be able to
use the device once it has cooled down.
If the resistance of the coil is lower than 0.1 ohm in VW mode or 0.05 ohm in TC or TCR mode, the display shows “
ATOMIZER LOW
”.
If an voltage surge occurs at the atomizer, the unit will display “ATOMIZER SHORT”. The display will read “
NO ATOMIZER FOUND
” when
there is no atomizer connected.
If the temperature of the atomizer coil is above the temperature you set, the device will display “
TEMP PROTECT
”. You can continue to use
the device normally.