background image

STEALTH DIGI-ARC140ST DV

Problems 

Causes 

Solutions

Power lamp not lit 

1. No electricity input 

1. Check incoming line

 

2. Machine switch fails 

2. Replace switch

Fan not rotating 

1. Fan power line is off 

1. Reconnect the line

 

2. Fan enclosure is blocked 

2. Unblock the enclosure 

 

3. Fan fails 

3. Replace the fan

 

4. Machine fails 

4. Return to manufacturer or

 

 

    service centre

Warning lamp lights  1. Over heat (yellow lamp lights) 

1. Welding after cooling

 

2. Over current (Green lamp lights)  2. Input voltage too low or the 

 

 

    machine fails

No output of welder  1. Over current protection 

1. Over load using

 

2. Welder fails 

2. Maintenance in manufacturer 

 

 

    or service centre

Output current 

1. Input voltage is low 

1. Stabilise over 5KVA 

decreased 

2. Input line is too thin 

2. Thicken power line

Current cannot be 

1. Connecting line of the 

1. Reconnect the line

regulated 

    potentiometer is off 

 

2. Potentiometer for current  

2. Replace potentiometer 

 

    regulation fails

TROUBLESHOOTING

Summary of Contents for DIGI-ARC140ST DV

Page 1: ...IGBT INVERTER DC MMA LIFT TIG WELDING MACHINE Part No 9020 DIGI ARC140ST DV OPERATING INSTRUCTIONS Suitable for 110V or 240V...

Page 2: ...HINE WHEN REPAIRING OR ADJUSTING INSPECT BEFORE EVERY USE ONLY USE IDENTICAL REPLACEMENT PARTS 10 FOLLOW ALL MANUFACTURER S RULES ON OPERATING SWITCHES AND MAKING ADJUSTMENTS 11 ALWAYS WEAR PROTECTIVE...

Page 3: ...easures of the welder are excellent The machine is reliable light weight and easy to use It is particularly suitable for plant and mine build decoration and maintenance sectors 2 OPERATING CONDITION A...

Page 4: ...ng column connect the protection grounding of the welder d Welding operation should be carried out in dry and good ventilating area The surrounding objects should be not less than 0 5m away from the w...

Page 5: ...nnection B positive connection HOLDER WORKPIECE HOLDER WORKPIECE 6 2 DC ARGON ARC WELDING LIFT TIG 6 2 1 Put switch 2 MMA TIG switch onto the position TIG 6 2 2 Connect gas inlet pipe of the welding t...

Page 6: ...amp lights 1 Over heat yellow lamp lights 1 Welding after cooling 2 Over current Green lamp lights 2 Input voltage too low or the machine fails No output of welder 1 Over current protection 1 Over loa...

Page 7: ...Do not touch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese d...

Page 8: ...tila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci n de poder de la m quina antes de iniciar cualquier servicio D branchez le...

Reviews: