3. Instructions for start up

3.1 Positioning

BASICS

• The equipment comes with a suction tube and with an

impulsion tube, the first having a larger diameter than

the second. Assembling is designed in such a manner

that it is impossible to assemble the tubes mistakenly

or to insert them mistakenly into the sockets.

• Depending on the use, you may mount the one-

segment the two-segment tube by means of the pin

connection and the pair of screws thereof.

• As a safety measure, the machine has a sensor that

prevents operation when the cover (14) of the suction

device is open or the conduct is not installed well.

• Always position the tubes with the motor turned-off.

ASSEMBLING THE IMPULSION TUBE

• Insert the tube directly into the socket 14 respecting the

upper groove and tighten the fastening wing nut. If you

wish, you may mount the deflector terminal to increase

the sweeping pressure.

ASSEMBLING THE SUCTION TUBE

• Open the lid of the suction socket 13 by smoothly

levering with a flat screwdriver at the right of the retainer

clip 16.

• Insert the tube in such a manner that the radial

projection presses on the safety sensor that is next to

the hinge of the lid 14. Once introduced turn leftwards

to fasten the tube.

• Assemble the suction bag to the impulsion socket by

fitting the upper pin and tightening the fastening wing

nut.

Before carrying out any work at the blower, 

always stop the motor and separate the spark 

plug connectors.

Always wear protective gloves.

Start the blower only after having assembled it 

completely.

WARNING:

Do not try to collect large wood shavings, metal, 

glass, stones, liquids, lighted cigarettes, pyrotechnic 

products or similar ones.

Always assemble the tube of the suction device 22 in the 

correct manner before starting the machine. Operation 

without the tube of the suction device 22 is dangerous; 

the propeller may trap your fingers or clothing and cause 

serious damages.

Do not try to disassemble the tube of the suction device 22 

when the machine is operating.

3.2 Illustrated description of functions

1. ON/OFF  switch.

2. Main  handle.

3. Trigger.

4. Priming  pump.

5. Air filter cover.

6. Choke  lever.

7. Starter  knob.

8. Fuel  tank.

9. Fuel tank lid.

 10. Muffler.

 11.   Support  grip.

 12.   Sparkplug.

 13. Cover of the suction device.

 14. Suction device duct.

 15. Suction cover clip.

 16. Air filter cover clip.

4. Operating instructions

WARNINGS:

• Do not allow the motor to be started at a place where

refueling has been made.

• Exhaust gas is toxic. Do not start the motor at a location

without adequate ventilation such as interiors, tunnels,

etc.

• Once started, if felt rare in sound, smell, vibration, etc.

stop the motor immediately and check it.

• Check that the motor will stop when the stop switch is

in position “O”.

• When the choke lever is raised higher than he position

“CLOSE” the motor may become damaged.

• When the motor detonates and stops, put this lever

again into position “OPEN” and pull the starter knob

several times to start the motor again.

• If the operator keeps on pulling the starter when the

lever of the throttle is in position “CLOSE”, it is possible

that  it  results  difficult  to  start  the  motor  due  to  fuel

flooding.

• In case of fuel choking, remove the sparkplug and pull

the grip several times to discharge any excess of fuel.

Dry the sparkplug’s electrode.

4.1 General instructions for use

Starting mode

1) When the motor is cold or after refueling:

-  Place the machine on a flat surface.

-  Put the stop switch into position “I”.

-  Continue pushing the priming pump until fuel enters

into it.

• Generally, fuel enters into the carburetor after having

pushed 7 to 10 times.

• When the priming pump is pushed excessively, an

excess of gasoline returns to the fuel tank.

-  Turn the choke lever (starter) to the left to the closed

position.

-  Hold the main handle with your left hand to avoid 

that the motor moves.

Summary of Contents for GAS VENTO25

Page 1: ...es rea Empresarial Andaluc a Sector 1 C Sierra de Cazorla 7 28320 Pinto Madrid SPAIN Email sales grupostayer com Email info grupostayer com GAS VENTO25 IT GB FR P Istruzioni d uso Operating instructio...

Page 2: ...2 2 FIG 1 FIG 2 2 16 5 8 10 14 11 11 12 3 9 7 6 13 2 8 9 4 5 6...

Page 3: ...3 3 FIG 4 FIG 3 2 1 3 2 7 13 13 1 14 10 11 15 16...

Page 4: ...ENGLISH 4 4 6 1 GAS VENTO25 KW 0 65 min 1 3000 9000 C C cm3 25 m 0 9 L 450 Km h 322 m3 min 12 2 L 0 6 Kg 2 5 K 3db LPA dB A 99 LWA dB A 107 K 1 5 m s2 ah m s2 4...

Page 5: ...ctive gloves are to be used Wear ear protectors Keep persons and animals out of the working area Wear eye and ear protection Fuel gasoline Manual start of the motor Emergency stop First Aid Recycling...

Page 6: ...d suffocation Carbon monoxide is an odorless gas Always make sure that there is a correct ventilation Stop the motor when resting and when leaving the blower unattended Place it at a safe location to...

Page 7: ...the suction device 22 is dangerous the propeller may trap your fingers or clothing and cause serious damages Do not try to disassemble the tube of the suction device 22 when the machine is operating 3...

Page 8: ...e Empty the bag before it has been filled completely You may cause fire Hang the belt of the dust bag over your shoulder and adjust the length of the belt to facilitate operation Make sure that the du...

Page 9: ...chine for a long period of time drain all fuel from the fuel tank and carburetor and keep it at a dry and clean site Discharge fuel completely from the fuel tank and carburetor in accordance with the...

Page 10: ...ith address at Calle Sierra de Cazorla 7 rea Empresarial Andaluc a Sector 1 28320 PINTO MADRID Tel 34 91 691 86 30 Fax 34 91 691 86 31 CERTIFIES That the machine Type Mulching Vacuum Blower Models GAS...

Page 11: ...www grupostayer com rea Empresarial Andaluc a Sector 1 C Sierra de Cazorla 7 28320 Pinto Madrid SPAIN Email sales grupostayer com Email info grupostayer com...

Reviews: