8 Components of the Stud Welding Unit
©Walter Stauffenberg GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
8.2
Operation Panel and Display
1
2
3
4
5
6
1
2
3
4
5
6
- Welding current
- Welding time
- Ready indicator
- Contact
- Trigger
- Temperature
In the lower part of the operation panel are light-emitting diodes (LED) with the
following meanings:
Yellow
Lights up when the stud welding unit is ready for welding.
Yellow
Lights up when electrical contact exists between the welding
element and the workpiece.
Yellow
Lights up when the welding gun button is triggered.
Yellow
The stud welding unit is locked
– if the stud welding unit is overheated. After a short cooling
period, the work can be continued.
8.3
Mains Switch
1
The switch for mains mode is located on the
rear of the stud welding unit.
1 - Mains switch