D2275-02-02 SEM315 CN4978 WEB User guide 

Fig 2

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
* Resistance Range, (10 to 390) 

 (End to End) Larger values can be accommodated by linking 

terminals as shown. 
 

 

4.0 HART PROGRAMMING

 

 
Consult HART website for more details: www.hartcomm.org 
 

 

4.1 CONNECTION ARRANGEMENT FOR HART COMMUNICATOR

 

 

Fig 3.1a

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Page 5 

Fig 3.1b

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

4.2 CONNECTION ARRANGEMENTS FOR HART MODEM (e.g. M-CONFIG)

 

 
 

Fig 3.2a

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Page 6 

R   > 250 

L

mA

-

+

Current 

Meter

+

-

Power 

Supply

- Black 

Connector

+

HART Modem 

(To PC)

-

1 (+)

2 (-)

+ Red 
Connector

Summary of Contents for SEM315

Page 1: ...TTER Status Instruments Ltd Green Lane Business Park Tewkesbury Glos GL20 8DE Tel 44 0 1684 296818 Fax 44 0 1684 293746 Email sales status co uk Web www status co uk INDEX SECTION CONTENTS PAGE NO 1 0 DESCRIPTION 1 2 0 SPECIFICATION 1 3 3 0 INSTALLATION 4 5 4 0 HART PROGRAMMING 5 7 ...

Page 2: ...e X 3 User defined Linearisation BS EN60584 01 BS 4937 IEC 584 1 multi segment Polynomials Basic Measurement Accuracy 2 0 04 FRI 0 04 RDG or 0 5 C whichever is greater Thermal Drift Span 0 01 C Cold Junction Error 0 5 C Cold Junction Tracking 0 05 C C Cold Junction Range 40 to 85 C Page1 2 3 MILLIVOLT INPUT Input Voltage Source Range 10 to 75 mV Characterisation Linear Custom X 3 Minimum Span 5 mV...

Page 3: ... be mounted in any orientation Care must be taken when locating the transmitter to ensure the ambient temperature remains within the specified operating range Figure 1 shows the mechanical layout of the transmitter Fig 1 All Dimensions in mm 3 2 ELECTRICAL Connections to the transmitter are made to the tension clamp terminals provided on the front face Output signal wiring should use screened twis...

Page 4: ...g terminals as shown 4 0 HART PROGRAMMING Consult HART website for more details www hartcomm org 4 1 CONNECTION ARRANGEMENT FOR HART COMMUNICATOR Fig 3 1a Page 5 Fig 3 1b 4 2 CONNECTION ARRANGEMENTS FOR HART MODEM e g M CONFIG Fig 3 2a Page 6 R 250 L mA Current Meter Power Supply Black Connector HART Modem To PC 1 2 Red Connector ...

Page 5: ...or or HART modem across the load in Figure 3 1a and 3 2a respectively Page 7 ALSO AVAILABLE Smart In Head Temperature Transmitters Din Rail Mounted Temperature Transmitters Panel Field Temperature Indicators Temperature Probes Trip Amplifiers Signal Conditioners And many other products For further information on all products Status Instruments Ltd Green Lane Business Park Tewkesbury Glos GL20 8DE ...

Reviews: