Precision Level System

User Guide

BA 1044 E  07/15

Summary of Contents for BG 840100

Page 1: ...Another fine solution by Precision Level System User Guide BA 1044 E 07 15 ...

Page 2: ...mprove ments or changes to the product range have been carried out Use the link below to make sure you have the most up to date version of your User Manual www statuspro com The System includes the following 1 x BT 840100 µLevel single 1 x BT 840110 Case for µLevel 1 x BT 840120 Foam inlay for µLevel Case 1 x BT 840170 Optional Software Smartlevel Pro Cable Kit Please make sure that your system is...

Page 3: ...nction of the Level Meter 15 4 6 Measurement Connecting with Computer 15 5 ADJUSTMENT OF THE APPARATUS 16 5 1 Relative Zero Setting 16 5 2 Absolute Zero Setting 16 5 3 Scale of the Apparatus Displayed Value 17 5 4 Renew the Leave Factory Settings 18 6 TECHNICAL DATA 19 7 LEVEL ANDROID SOFTWARE OPTIONAL 20 7 1 Software Installation 20 7 2 µLevel registration 20 7 3 Differential Delta and Rightangle...

Page 4: ...ness of products could be measured automatically and calculated measuring result and graph could be output and printed Ergonomical Design self contained functions will bring your measur ing work beat all surprise and kilter As this Digital Level Meter has a lot of functions carefulness reading of the operation manual before using could guide you making full use of the various functions 2 Notes on ...

Page 5: ...spray as well as dust Clean the equipment using a soft cotton cloth and a mild soap solution Laser apertures as well as well as sensor areas should only be cleaned using a soft dry and dust free cloth Do not use paper towels to clean glass surfaces as they could scratch Avoid contact with grease oil or oil based solutions when handling the equipment Caution Do not try to recharge normal batteries ...

Page 6: ...re trouble free processing of the service and calibration checks simply fill in the form you will find using the following link www statuspro com 2 5 Liability Exclusion The Status Pro GmbH does not accept responsibility for damage incurred through incor rect use or handling of the equipment To ensure correct usage a founded knowledge of the equipment is essential It is of the utmost importance th...

Page 7: ... Reminding When begin to blinking all of the batteries should be replaced New batteries could not be mixing used with old batteries If the apparatus will not be used for a long time the batteries should be taken out in case of the leakage of the batteries rust other components which may cause the apparatus can not work New batteries could not be mixing used with old batteries 3 2 Button panel Indu...

Page 8: ...n mm Display for measuring unit in inch Measurement with 1µm m resolution Measurement with 10µm m resolution Zero Setting Voltage Temperature Read stored data Delete stored data Scale Restoration Serial number Serial number for current data The last data stored Display of measurement readings Power low Tilt direction display right side high Tilt direction display left side high Minus display Radix...

Page 9: ...djustment zero setting reading reset see Function Choice Touch the button radian unit mm m and angle unit second could be transformed This function could only be available at measuring phase and no use at other measuring phase 1 When choose radian unit to measure it display the measuring unit mm m It expresses the gradient height difference at length of 1 meter In the practice inspection as the sp...

Page 10: ...asuring phase suit to different accuracy inspections Please choose proper product and measuring phase accordingly The higher measuring phase limit the temperature and environment strictly If environment and temperature could not be ensured as requested the apparatus may be not stabilized Zero Setting Being at this mode press button and the Level Meter zero position could be set 1 At the working su...

Page 11: ... at left of the E level meter press once SCL RST button LED will show then scale at Small Angle Inspection Instrument Reminding The E level meter need to be scaled at Small Angle Inspection Instrument by metrology unit could not be scaled by end user unbending in case effect the measuring accuracy of the E level meter Restoration Plug the instrument screwdriver into the small hole at left of the E...

Page 12: ... 2 C humidity less than 75 and temperature variation per hour less than 1 C Reminding The level meter may hop count when the environment can not meet the requirement above Please remain enough time for constant temperature if the working environment changed frequently If the display data of level meter more than 1999 the data will beating and flashing all the time means it beyond the measuring ran...

Page 13: ...w at the left side of the shown value tilt direction show Figure a2 3 If tilt angle is over the show range 1999 the displayed value will blinking ceaseless The maximum display is 9999 4 3 Level Inspection and Adjustment for Working Surface 1 Put the Digital E level meter on the inspected surface record the first shown value a1 Then transfer the E lever meter by 180 at the same position the second ...

Page 14: ...rface nor mally line by diagonal or reseau Please reference to concerned metrology and inspection rules for more detailed contents of the straightness flatness inspection and data processing Reminding Before the inspection the inspected surface need to be adjusted to be at level mode Digital E level meter need to be fixed reliably on the span bridge Measuring unit should be chosen mm m The directi...

Page 15: ...e first stored data Two kinds of measuring units could not be stored at same time in case something wrong happen at the application software when output Reminding When use store function in the measurement measuring data for several inspected work pieces could be stored When connect with the measuring soft ware of computer the sequence of data reading need to be noticed in case of confusion 4 6 Me...

Page 16: ...r of the digital level meter 5 2 Absolute Zero Setting Turn around the level meter by 180 degree 1 Keep the digital level meter unchanged press key or once then turn around the level meter by 180 degree replace it to original posi tion press key or once again then the digital level meter has been adjusted to absolute zero position the displayed value of the level meter at this time is the offset o...

Page 17: ...Put the digital level meter being scaled on the level working table of the small angle inspection instrument make its vertical direction to be same as that of the digital level meter then insert the plug of the control box into the handgrip of the level meter Digital level meter being scaled level working table indication needle gauges adjust screw bridge shape working table 3 Insert the instrumen...

Page 18: ... side indication needle adjust the small angle inspection instrument and make the displayed value of the indication needle to zero position at such time press the key Delete of the control box the level meter will show 500 8 Insert the instrument screwdriver into the small hole at left side of the digital level meter press the scale restoration key twice when LED show then it comes into the measur...

Page 19: ... error in measurement range 1 A 2 A measurement value in µm m Stability 6 µm 4h Repeating accuracy 1µm m Stability time 10 seconds Zero values error 1µm m Environmental condition 20 2 C temperature change 0 5 C h Power supply 4 x AA batteries or rechargeable batteries Operating time approx 14 hours Dimensions 150 x 47 x 170 mm Base length 150mm Base type Prisma Weight 1 3 kg ...

Page 20: ...te Unknown Sources You can now Install the apk File with the µLevel Ext Display Software 7 2 µLevel Registration When you start the app you will see the following Screen First you will need to connect one of your µlevels to your Android per Bluetooth The first time you connect the µLevel to your Android you must go to Set up and then Bluetooth settings Now select Scan for devices make sure that yo...

Page 21: ... your chosen µLevel will be continuously displayed on your Android Display and Functions Direction of Inclination The Software displays the direction of inclination oft the µLevel A small µLevel symbol is displayed adjacent the measured value Zeroing Just press the 0 symbol to Zero your µlevel at ist current value The measured value will correspondingly change to 0 21 LEVEL ANDROID SOFTWARE Status...

Page 22: ...u will have one of the following setups Either you want a differ ential measurement µL1 µL2 or you are using both at rightangles and you want the resultant inclination To toggle just touch the symbol on the third line Display transfer of the µLevel The µLevel will only transmit data to your Android when the µLevel is in the measurement mode I or II II In measurement mode II the range is 4 Decimal ...

Page 23: ...laces If the µLevel is doing something else like ZERO VBAT C DATA oder DEL the Android will display MODE Go back to measurement mode I or II and you will see the vales displayed again 7 4 Disconnect and exit the app Tip the Bluetooth symbol on the unit you wish to disconnect The disconnect dialog will start ...

Page 24: ... Card recommend Installation of the Software There are two possible ways of installing the SmartLevel Pro Software 1 Installation with Browser Before starting the installation make sure that all the instruments are correctly connected and the interface SD Serial 0 or DL serial is also properly installed to the serial port to the computer COM1 Insert the install CD into the CD ROM drive of your com...

Page 25: ...Follow the directives on the monitor Removal of the Software The software SmartLevel Pro can be removed as follows 1 Chose SET UP CONTROL PANEL SOFTWARE in the filed installed software you will find SmartLevel Pro 2 With REMOVE the software will be removed from your PC 8 2 Program Operating Main icon Straightness Parallelism icon Flatness icon File Menu 25 Status Pro µLevel User Guide SMARTLEVEL P...

Page 26: ...d of Straightness The Least Square Evaluate Method of Straightness The Minimum Zone Evaluate Method of Straightness The EndPoint Evaluate Method of Paralism The Least Square Evaluate Method of Paralism The Minimum Zone Evaluate Method of Paralism The Grid Evaluate Method of Flatness The Diagonal Evaluate Method of Flatness The Least Square Evaluate Method of Flatness The Minimum Zone Evaluate Meth...

Page 27: ...Dicay Var Calculate 8 4 Measuring object The Basic 1 Instrument Connected to Computer 2 Change the Instrument On Measuring Process 3 General Information About Error 4 In the Software the following methods of aligning the measuring objects are possible Alignment according to the method Endpoints Alignment according to the method MinZone ISO 1101 Alignment according to the method Least Square Linear...

Page 28: ...ing Straightness Step 1 The Parameter Setup L Length The Measuring length click the mouse right key to standard length StepN Step Number StepL Step Length StepL L StepN 2 The Measuring Process KeyBoard Read one Data SMARTLEVEL PRO SOFTWARE ...

Page 29: ...gning Measuring Paralism Step 1 Setup Parameter L Length The Measuring length click the mouse right key to standard length StepN Step Number StepL Step Length StepL L StepN 29 Status Pro µLevel User Guide SMARTLEVEL PRO SOFTWARE ...

Page 30: ...Keyboard Online Import Data Methods of aligning Paralism Measuring Flatness Step With Grid 1 Setup Parameter L Length The Measuring length click the mouse right key to standard length StepN Step Number StepL Step Length StepL L StepN SMARTLEVEL PRO SOFTWARE ...

Page 31: ...31 Status Pro µLevel User Guide 2 The Measuring Process 3 Methods of aligning Flatness 4 Color Graph 5 Calculated Data 6 Measuring Data SMARTLEVEL PRO SOFTWARE ...

Page 32: ...uring Flatness Step With Diagonal 1 Setup Parameter L Length The Measuring length click the mouse right key to standard length StepN Step Number StepL Step Length StepL L StepN 2 The Measuring Process 3 Color Graph SMARTLEVEL PRO SOFTWARE ...

Page 33: ...use of a laser beam reference together with tradition industrial measurement techniques has made it possible to build tools which simplify these alignment procedures Status Pro develops and manufac tures laser alignment equipment and we are committed to this process Most of our customers are machine builders assembly and quality control people Typically our customers require a complete solution pa...

Page 34: ...34 Status Pro µLevel User Guide PRODUCTS SERVICES ...

Page 35: ...35 MEMO Status Pro µLevel User Guide ...

Page 36: ...15 Status Pro Maschinenmesstechnik GmbH This document or parts thereof may not be copied or other wise reproduced without the permission of Status Pro GmbH The technical details are subject to change without notifi cation We would appreciate being informed of any errors in this document ...

Reviews: