Static Clean Hepa Clean 3000 Installation Operation & Maintenance Download Page 3

A

Ad

djju

us

sttiin

ng

g  tth

he

e  P

Ph

ho

otto

oe

elle

ec

cttrriic

c  c

ce

ellll  iin

n  tth

he

e  c

clle

ea

an

niin

ng

g  c

ch

ha

am

mb

be

err::

Before adjusting the cell be sure that the perforated stainless
steel work surface on the floor of the cleaning chamber is
clean, in place and properly seated and that the cell is facing
straight downward. If not, the cell will not perform properly or
may not perform at all.

To adjust the eye:

• Turn the system switch to the automatic position.
• Use a small eyeglass screwdriver to turn the sensitivity

adjustment screw (on the cell) counter clockwise all
the way. The green LED on the cell should not be
illuminated at this time. Make sure neither your hand
nor any other object is obstructing the face of the cell
while you slowly turn the sensitivity adjustment screw
clockwise just enough until the green LED lights up.
Stop there.

• Check this adjustment by putting your hand under the

cell; this should activate the system and set it up for
maximum sensitivity.

• Next, adjust the time delay to a setting that would

enable the operator sufficient cleaning time and shut
off after a reasonable idle time. (1second to 30
seconds)

Spare Parts

7.5Kv Power Supply item # 2224
Static Bar item # 4402
Blower item # 1230
Blower Capacitor item # 3089
Blower Inlet Guard item # 3091
Pre-filter Assembly item # 4212
HEPA Filter item # 1231
Photoelectric cell item # 1229
Fluorescent Light assembly item # 2537

Specifications

Exterior

Cleaning Chamber

Width:

14 inches

14 inches

Height:

26 inches

10 inches

Depth:

33 inches

20 inches

Weight:

approximately 95 pounds

Max. Current:

3 amperes

Input Power:

115 VAC 50/60Hz

Features:

• Stainless Steel Construction
• HEPA filter (99%efficient at 0.3 micron)
• Multi-layered pre-filter
• Direct drive high velocity air blower with balanced

impeller for quiet operation

• Lighted rocker switch
• Fluorescent Interior work light
• Perforated stainless steel work surface
• Motion sensor for automatic operation
• Solenoid valve for automatic operation
• Removeable side panels for pass through operation;