ANTI-TILT DEVICE
The cooker must be fitted with an anti-tilt/restraint device to prevent it tipping
forward when in use. To use the floor mounted bracket supplied, see the
instructions provided.
LEVELLING
Place a spirit level on an oven pan or shelf and adjust the feet accordingly. Make
sure that the appliance is stable and does not rock.
GAS CONNECTION
Always grip the appliance inlet fitting firmly when
fitting the hose to prevent any damage occurring.
Never check for gas leaks with a naked flame.
The cooker is fitted with a ½’’ BSP internal thread situated at the rear right corner.
A flexible hose of correct rating in size and temperature should be used. For
Natural Gas it will be a black hose with a yellow band or label and should comply
with BS 669
LPG hoses should be suitable for LP gases up to 50 mbar pressure and 70
0
C
temperature rise. It will be a black hose with a red band or label.
Hoses should not exceed 1.5m in length.
Pressure setting – G20 Natural Gas @ 20 mbar
G30 Butane @ 28.3 mbar
G31 Propane @ 37 mbar
NOTE;
The gas hose and electrical cables of your cooker must
not come into direct contact with any hot or sharp surfaces or
objects. Do not move the appliance after the gas connection has
been made. Make sure that the hose is not kinked, damaged or
trapped.
1 5
Summary of Contents for LEGACY 50 GSLF
Page 2: ......