background image

16

Model TPG/TPX/TPO/TPD Limited Warranty

CERTIFIED FACTORY START - UP REQUIRED

To activate your warranty, contact your local sales representative or Authorized Start-up Agent to arrange for a FREE Certified Start-up.

State Water Heaters, the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater.

1. THE TANK

If the glass lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water

therein, during the first THREE years after initial installation, the warrantor will at its option, provide a replacement State water heater of equivalent

size and current model, less burner and controls. Some government agencies are requiring energy efficient standards for water heaters. In the

event regulations prohibit sale of a model of equivalent size and construction, State Water Heaters will provide a model which complies with the

regulations of your area, in which case the consumer will be charged the difference in price between the like replacement and the energy efficient
model required. The warranty on the replacement water heater will be limited to the unexpired term of the original warranty.

2. ALL OTHER PARTS

If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in

material or workmanship, the warrantor will repair such part or portion at its option.

3. CONDITIONS AND EXCEPTIONS

This warranty shall apply only if a certified factory start-up was performed and if the water heater is installed in accordance with local plumbing and

building codes, ordinances and regulations, the printed instructions provided with it and good industry practices.  In addition, a temperature and

pressure relief valve, approved by the American Society of Mechanical Engineers, must have been installed.

a)  This warranty shall apply only when the heater is:

(1)  owned by the original purchaser.

(2) sized in accordance with proper sizing techniques for commercial water heaters.

(3) bearing a rating plate which has not been altered, defaced or removed except as required by the warrantor.

(4) used in an open system, or in a closed system with a properly sized and installed thermal expansion tank.

(5) fired with the fuel for which it was factory built.

(6) fired at the factory rated input.

(7) used at temperatures not exceeding the maximum setting of its thermostat;

(8) used at water pressure not exceeding the working pressure shown on the water heater;

(9) used when operated free from the damaging effects of uncontrolled water hammer;

(10) used when filled with potable water, free to circulate at all times and the tank free of damaging water sediment or scaled deposits;

(11) in a non-corrosive and not-contaminated atmosphere;

(12) in its original installation location;

(13) used with factory approved anode(s) installed;

(14) in the United States, its territories or possessions, and Canada.

b)  Any accident to the water heater, any misuse, abuse (including freezing) or alteration of it, any operation of it in a modified

      form, or any attempt to repair tank leaks will void this warranty.

c)  This warranty is void if a device acting as a backflow prevention device (check valves etc.) is installed in the cold water supply the heater is

     connected to, unless an effective method of controlling thermal expansion is also installed at the heater(s) and operational at all times.  The

     relief valve installed on the heater is not an acceptable method.

4. SERVICE AND REPAIR EXPENSES

Under the limited warranty the warrantor will provide only a replacement water heater or part thereof. The owner is responsible for all other costs.

Such costs may include but are not limited to:

a)  Labor charges for service removal, repair or reinstallation of the water heater or any component part;

b)  Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest distributor and

     returning the claimed defective heater or part to such distributor.
c)  All cost necessary or incidental for any material and/or permits required for installation of the replacement heater or part.

5. LIMITATIONS ON IMPLIED WARRANTIES

Implied warranties, including the warranty of merchantability imposed on the sale of this heater under state law are limited to one (1) year duration

for the heater or any of its parts.  Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply
to you.

6. CLAIM PROCEDURE

Any claim under the warranty should be initiated with the dealer who sold the heater, or with any other dealer handling the warrantor’s products.

If this is not practicable, the owner should contact:

State Water Heaters
500 Lindahl Parkway
Ashland City, TN 37015

a)  The warrantor will only honor replacement with identical or similar water heater or parts thereof, which are manufactured or distributed by the

            warrantor.

b)  Dealer replacements are made subject to in-warranty validation by warrantor.

7. DISCLAIMERS

NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF OF THE WARRANTOR WITH RESPECT TO THE HEATER

OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE HEATER.  THE WARRANTOR SHALL NOT BE RESPONSIBLE

FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER

CONSEQUENTIAL DAMAGE.  THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE

TO ANY PERSONS OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING IN CONTRACT OR IN TORT.

a)  Some states do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may

      not apply to you

b)  This warranty gives you specific legal rights, and you may also have other rights, which may vary, from state to state.

Fill in the following for your own reference.  KEEP IT.  Registration is not a condition of warranty.  The model and serial number are found on the
heater’s rating plate.

Model No.

 _____________________ 

Serial No.

 ______________________________________ 

Date Installed 

___________________

Dealer’s Name __________________________________________________________________________________________________________
Dealer’s Address __________________________________________________________________Phone Number _________________________
City and State _____________________________________________________________________ Zip _________________________________

KEEP THIS WARRANTY POSTED ADJACENT TO THE HEATER FOR FUTURE REFERENCE.

Summary of Contents for TPD-140-140

Page 1: ...USING APPLIANCE ASME WARNING PROPANE MODEL Water heaters for propane gas are different from natural gas models A natural gas heater will not function safely on propane gas and no attempt should be ma...

Page 2: ...an Gas Association Laboratories 55 Scarsdale Road Don Mills Ontario Canada M3B 2R3 TABLE OF CONTENTS This manual is supplemented by the power burner manual All information including start up and maint...

Page 3: ...THE FLOW OF COMBUSTION AND VENTILATING AIR ADEQUATE AIR FOR COMBUSTION AND VENTILATION MUST BE PROVIDED FOR SAFE OPERATION LIQUID PETROLEUM MODELS Water heaters for propane or liquefied petroleum gas...

Page 4: ...American Insurance Association 85 John Street New York NY 11038 Note Some gas utility companies derate the heating value of the supplied gas at high elevations Your authorized State Start Up Agent mus...

Page 5: ...18 Inches FRONT 18 Inches BACK 0 Inches Back 6 Inches TOP 5 Inches Top 12 Inches LEFT SIDE 0 Inches LEFT SIDE 6 Inches RIGHT SIDE 0 Inches RIGHT SIDE 6 Inches NOTE If a chimney connector is used the m...

Page 6: ...STION OR RECIRCULATION OF FLUE GASES SUCH CONDITIONS CAUSE SOOTING OR RISKS OF FIRE AND ASPHYXIATION Heater must be protected from freezing downdrafts during shutdown periods Remove all soot or other...

Page 7: ...OCATED IN FREEZING AREAS DO NOT THREAD OR CAP THE END OF THIS LINE RESTRICTED OR BLOCKED DISCHARGE WILL DEFEAT THE PURPOSE OF THE VALVE AND IS UNSAFE DISCHARGE LINE SHALL BE INSTALLED TO ALLOW COMPLET...

Page 8: ...UAL GAS SHUTOFF VALVE BEFORE PLACING THE HEATER IN OPERATION CHECK FOR GAS LEAKAGE USE SOAP AND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THE PURPOSE OF LOCATING GAS LEAKS DO NOT USE MATCHES CAN...

Page 9: ...9 TYPICAL WIRE DIAGRAM TPG 270 2 500 KBTUH TPO 800 2 500 KBTUH TPD 400 2 500 KBTUH TYPICAL WIRE DIAGRAM TPG 140 255 KBTUH...

Page 10: ...10 TYPICAL WIRE DIAGRAM TPO 140 720 KBTUH TYPICAL WIRE DIAGRAM TPD 140 300 KBTUH...

Page 11: ...ired should be performed by an Authorized State Service Agent GENERAL NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTAL...

Page 12: ...Inspect Quarterly non detergent motor oil Power Burner Combustion and Ignition Inspection Semi Annually test kit Device 2 test specifications Main Burner Check Flame Annually Flue Baffle Pipe 3 Cleani...

Page 13: ...ary 9 Replace outer jacket cover plate RELIEF VALVE At least twice a year the temperature and pressure relief valve should be checked to ensure that it is in operating condition To check the relief va...

Page 14: ...n incoming water temperature was warm colder water creates the effect of less hot water 5 Look for hot water wastage and leaking or open hot water faucets 6 Sediment or lime scale may be affecting wat...

Page 15: ...ist of Installation of a second relief valve with lower setting than the primary relief valve An expansion tank of suitable size and pressure rating and provision to avoid water logging REPLACEMENT PA...

Page 16: ...evice acting as a backflow prevention device check valves etc is installed in the cold water supply the heater is connected to unless an effective method of controlling thermal expansion is also insta...

Reviews: