State Water Heaters SEH-200 Instruction Manual Download Page 20

20

Bottom of Menu

Elapsed time 

Total accumulated time the control system (water heater) has been 

energized.

total heating time

Total accumulated time the control system has been in the heating 

mode. IE: any heating elements have been energized.

Element # Cycles

Total  accumulated  count  of  heating  cycles  for  each  heating 

element.

Element # on time

Total accumulated heating on time for each heating element.

CCB Version

Software version for Central Control Board.

uIM Version

Software version for User Interface Module

CurrEnt fault / alErt MEnu

This menu displays non adjustable operational information. With the 

Fault History sub menu selected in Main Menu; press the Operational 

Button  underneath “SELECT” to display the current Fault or Alert 

message.  If  there  is  not  a  Fault  or Alert  condition  currently  active 

“(none)” is displayed to the right of this menu.

Main Menu - Current fault selected

fault hIstory MEnu

This  menu  displays  non  adjustable  operational  information.  The 

control  system  records  and  stores  the  last  9  Fault  and  Alert 

messages  in  chronological  order  in  this  menu.  The  most  recent 

will be at the top of the list. A time stamp is displayed below each 

listed  Fault  and Alert  message  showing  when  the  Fault  or Alert 

condition occurred.

The Fault History is useful when dealing with intermittent operational 

problems or when the customer has reset the control system prior to 

a service agent’s arrival.

With  a  Fault  or  Alert  item  selected  press  the  Operational  Button 

underneath  “VIEW”  to  display  the  details  for  the  Fault  or  Alert 

message. The Fault/Alert message screen displays a brief description 

of  the  condition,  contact  information  and  access  to  the Advanced 

service information sub menu.

fault history Menu

Current/history fault Message

fault oCCurrEnCE MEnu

Total  accumulated  number  each  individual  Fault  condition  has 

occurred  is  displayed  in  this  menu.  This  running  total  of  Fault 

Occurrences can be useful in determining which (if any) operational 

problems have been persistent.

fault occurrence Menu

Summary of Contents for SEH-200

Page 1: ...nstruction Manual place these instructions adjacent to heater and notify owner to keep for future reference COMMERCIAL ELECTRIC WATER HEATER MODELS SEV 150 THRU SEV 10000 SEH 200 THRU SEH 10000 UP TO...

Page 2: ...about the type of hazard what can happen if you do not follow the safety message and how to avoid the risk of injury The California Safe Drinking Water and Toxic Enforcement Act requires the Governor...

Page 3: ...perly may also cause erratic control system operation on ELECTRONIC CONTROL models This water heater must be connected to a grounded metal permanent wiring system or an equipment grounding conductor m...

Page 4: ...It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation operation and maintenance of the water heater It also contains warnings throug...

Page 5: ...ter circuits and includes wiring diagrams Control Circuits The water heater is equipped with an electronic control system The system includes a CCB Central Control Board circuit board an immersion tem...

Page 6: ...C1 C5 C4 C3 C2 C1 N GRN GRN BLK BLK X FMR ECO TEMP 120V BLK BLU RED RED RED RED SDI 24V X FMR PRIMARY FUSES X FMR 120V SEC SEC FUSE PILOT SWITCH BLK BLK JUMPER TO DISPLAY LWCO 5 4 3 2 1 FUSES CNTCTR...

Page 7: ...f scalds Some States require settings at specific lower temperatures See Figure 1 which shows the approximate time to burn relationship for normal adult skin MIXING VALVES DANGER Water temperature ove...

Page 8: ...water temperature This is an adjustable user setting in the control system s Temperatures Menu This and all control system menus are accessed through the UIM User Interface Module located on the front...

Page 9: ...irectly above each button on the LCD screen The function will change depending on what menu is currently displayed or what menu item is selected When no text appears on the LCD screen above an Operati...

Page 10: ...used the fault is corrected Power to the water heater must be cycled off and on to reset the control system Note cycling power will not reset the control system if the condition that caused the fault...

Page 11: ...peration total heating cycle time heating cycle count heating element s cycle count and on time along with UIM and CCB software revisions can be viewed in this menu Current Fault Alert Displays any cu...

Page 12: ...equipped with 3 heating elements with an Operating Set Point of 120 F and all Differential settings at 2 F the On Off sequencing of heating elements would be as follows ELEMENT NUMBER DIFFERENTIAL SET...

Page 13: ...eratures is not selected use the Up and Down buttons to select this menu item With the Operating Set Point selected highlighted in black in the Temperatures Menu press the Operational Button underneat...

Page 14: ...ontacts on the external control per all applicable building codes This is a switching circuit only DO NOT apply any external voltage or connect any load IE relay coil to either circuit Element On Disp...

Page 15: ...or not Daily Operating Mode Sun Mon Tue Wed Thu Fri Sat Seven daily sub menus are listed at the bottom of the Economy Mode Setup menu There are 3 Operating Modes in each sub menu Normal Operation All...

Page 16: ...ss the Operational Button underneath CHANGE to activate the adjustment mode for the Setpoint Adjustment value Use the Up Down buttons to change the Setpoint Adjustment to the desired value The Setpoin...

Page 17: ...s to ACCEPT CANCEL when the adjustment mode is activated and how the current setting is outlined rather than highlighted in black Press the Operational Button underneath ACCEPT to enter and confirm th...

Page 18: ...E buttons to enter the Mon sub menu as described above Use the Up Down buttons to select highlight in black the Normal Operation Between setting Press the Operational Button underneath SELECT to chang...

Page 19: ...ternal notification when current tank temperature drops below programmable Alarm SP Fault or Alert Used for external notification whenever a Fault or Alert condition is active Fault Used for notificat...

Page 20: ...menu displays non adjustable operational information The control system records and stores the last 9 Fault and Alert messages in chronological order in this menu The most recent will be at the top o...

Page 21: ...actory Defaults ACTION DISPLAY From the Main Menu use the Up Down buttons to select highlight in black the Restore Factory Defaults menu Press the Operational Button underneath SELECT The Restore Fact...

Page 22: ...it switch may have activated See the Temperature Regulation section of this manual for more information on how to reset the ECO high limit controls Repeated activation of the ECO high limit switch sho...

Page 23: ...NOTES...

Page 24: ...500 Tennessee Waltz Parkway Ashland City TN 37015 Phone 800 365 0024 Parts 800 433 2545 Fax 800 644 9306 www statewaterheaters com Copyright 2010 A O Smith Corporation All rights reserved...

Reviews: