10
Vertical Height (Extension Kit)
It is simple to determine which kit is needed for vertical height. Take the
total height (to the top of the flue) required and comparing that to “F
dimension” in the chart #1, it can be determined which kit needs to be
used vertically.
FIGURE 11.
FIGURE 12.
CHART #1.
BTU’s
DIMENSION “F” (IN INCHES)
*Gal.
in 1000’s
9000687 9001246
9001247
9001248
Cap. Nat/L.P
STD.
MI N.
MAX.
MIN.
MAX.
MIN.
MAX.
40
36/36
63 3/4
72
77
77
88
88
110
50
38/38
72
80 3/4
86
86 1/4 97 1/4
97 1/4 118 3/4
40
40/40
63 3/4
72
77
77
88
88
110
50
48/44
76
84 1/4 89 3/4 89 3/4 100 3/4 100 3/4 122 3/4
75 55 NAT.
76 1/4 84 1/2 89 1/2 89 1/2 100 1/2 100 1/2 122 1/2
BTU’s
DIMENSION “F” (IN CENTIMETERS)
*Gal.
in 1000’s
9000687 9001246
9001247
9001248
Cap. Nat/L.P STD. MIN. MAX. MIN. MAX. MIN. MAX.
40
36/36
162
183
196
196
224 224 279
50
38/38
183
205
218
219
247
247 302
40
40/40
162
183
196
196
224 224 279
50
48/44
193
214
228
228 256 256 312
75 55 NAT.
194
215
227
227 255 255 311
*Check the model and rating plate attached to the water heater for
specific model number and other detailed information.
Horizontal (Extension Kit)
To determine the horizontal length and extension kit needed, simply
plug the dimensions “D” and “G” into the equation below. The answer
“E” should then be located in Chart #2. The size range in which “E”
dimension falls indicates the kit that should be used horizontally to
obtain the desired length.
“D”
= The wall thickness
“G”
= The distance wanted between the edge of the water heater
and the
inside
edge of the wall
“E”
= The distance the extension kit must be able to extend
The Equation: D + G = E
FIGURE 13 .
CHART #2.
DIMENSION “E” (IN INCHES)
40-50 GAL.
75 GAL.
VENT KITS
MIN
MAX
MIN
MAX
9000687-Std.
3 1/2
10
7/8
7 3/8
9001246
10
15 1/2
7 3/8
12 7/8
9001247
15 1/2
26 1/2
12 7/8
23 7/8
9001248
26 1/2
48
23 7/8
45 3/8
DIMENSION “E” (IN CENTIMETERS)
40-50 GAL.
75 GAL.
VENT KITS
M I N
MAX
M I N
MAX
9000687-Std.
8.9 cm
25.4 cm
2.2 cm
18.7 cm
9001246
25.4 cm
29.4 cm
18.7 cm
32.7 cm
9001247
39.4 cm
67.3 cm
32.7 cm
60.6 cm
9001248
67.3 cm
121.9 cm
60.6 cm
115.3 cm
BTU’s
DIMENSION “A, B, C” ( INCHES /CENTIMETERS )
*Gal.
in 1000’s
Cap. Nat.
A
B
C
40
36/36
48 3/4”
124 cm
41 3/4”
106 cm
21”
53 cm
50
38/38
57 1/2”
146 cm
50 1/2”
128 cm
21”
53 cm
40
40/40
48 3/4”
124 cm
41 3/4”
106 cm
21”
53 cm
50
48/44
61”
155 cm
54”
137 cm
21”
53 cm
75 55 NAT.
63”
160 cm
54 3/4”
139 cm
26 1/4” 67 cm