background image

Nominal

Input

Output (Gallons)

Storage

Rating

Ship.

Model Number

Capacity

BTU/Hr.

First

Recovery

Dimensions In Inches

Wt.

Motor HP

U.S.

Natural

Hour

w/Burner

120V 60 Hz 1

Gallons

Gas

Rating

80°F Rise 100°F Rise 140°F Rise

A

B

C

D

E

F

G

H

J

(lbs.)

TPG 150 140 NEA

150

140,000

256

170

136

97

83

1

2

14

1

2

27

3

4

1

1

4

36

1

2

5

47

73

1292

TPG 150 199 NEA

150

199,000

313

241

193

138

83

1

2

14

1

2

27

3

4

1

1

4

36

1

2

6

47

73

1292

1

7

HP - 2.5 Amps

TPG 150 255 NEA

150

255,000

367

359

247

176

83

1

2

14

1

2

27

3

4

1

1

4

36

1

2

6

47

73

1292

TPG 150 270 NEA

150

270,000

382

327

262

187

83

1

2

14

1

27

3

4

1

1

4

36

1

2

6

57

1

2

73

1397

TPG 150 400 NEA

150

400,000

507

485

387

277

83

1

2

14

1

27

3

4

1

1

4

36

1

2

7

57

1

2

73

1397

1

4

HP - 4.6 Amps

TPG 150 540 NEA

150

540,000

644

654

524

374

83

1

2

14

1

27

3

4

1

1

4

36

1

2

8

57

1

2

73

1505

TPG 150 720 NEA

150

720,000

818

873

698

499

83

1

2

14

1

1

4

27

3

4

1

1

4

36

1

2

10

57

1

2

73

1510

1

3

HP - 5.5 Amps

TPG 200 300 NEA

200

300,000

451

364

291

208

83

1

2

15

1

32

1

2

1

1

2

44

3

4

6

66

1

2

73

2098

1

4

HP - 4.6 Amps

TPG 200 600 NEA

200

600,000

742

727

582

416

83

1

2

15

1

32

1

2

1

1

2

44

3

4

8

66

1

2

73

2098

TPG 200 800 NEA

200

800,000

936

970

776

554

83

1

2

15

1

1

4

32

1

2

1

1

2

44

3

4

10

66

1

2

73

2103

1

3

HP - 5.5 Amps

TPG 200 1000 NEA

200

1,000,000

1130

1212

970

693

83

1

2

15

1

1

4

32

1

2

1

1

2

44

3

4

10

66

1

2

73

2103

TPG 200 1250 NEA

200

1,250,000

1372

1515

1212

866

83

1

2

15

1

1

4

32

1

2

1

1

2

44

3

4

12

66

1

2

73

2467

1

2

HP - 7.4 Amps

TPG 200 1500 NEA

200

1,500,000

1615

1818

1455

1039

83

1

2

15

1

1

2

32

1

2

1

1

2

44

3

4

12

81

1

2

73

2757

TPG 300 300 NEA

300

300,000

531

364

291

208

91

1

2

14

1

26

1

2

1

1

2

44

3

4

6

66

1

2

83

2150

1

4

HP - 4.6 Amps

TPG 300 600 NEA

300

600,000

822

727

582

416

91

1

2

14

1

26

1

2

1

1

2

44

3

4

8

66

1

2

83

2150

TPG 300 800 NEA

300

800,000

1016

970

776

554

91

1

2

14

1

1

4

26

1

2

1

1

2

44

3

4

10

66

1

2

83

2308

1

3

HP - 5.5 Amps

TPG 300 1000 NEA

300

1,000,000

1210

1212

970

693

91

1

2

14

1

1

4

26

1

2

1

1

2

44

3

4

10

66

1

2

83

2308

TPG 300 1250 NEA

300

1,250,000

1452

1515

1212

866

91

1

2

14

1

1

4

26

1

2

1

1

2

44

3

4

12

66

1

2

83

2584

1

2

HP - 7.4 Amps

TPG 300 1500 NEA

300

1,500,000

1695

1818

1455

1039

91

1

2

14

1

1

2

26

1

2

1

1

2

44

3

4

12

81

1

2

83

2774

TPG 400 600 NEA

400

600,000

902

727

582

416

91

1

2

15

1

32

1

2

2

55

8

76

1

2

81

3207

1

4

HP - 4.6 Amps

TPG 400 800 NEA

400

800,000

1096

970

776

554

91

1

2

15

1

1

4

32

1

2

2

55

10

76

1

2

81

3212

TPG 400 1000 NEA

400

1,000,000

1290

1212

970

693

91

1

2

15

1

1

4

32

1

2

2

55

10

76

1

2

81

3212

1

3

HP - 5.5 Amps

TPG 400 1250 NEA

400

1,250,000

1532

1515

1212

866

91

1

2

15

1

1

4

32

1

2

2

55

12

76

1

2

81

3212

TPG 400 1500 NEA

400

1,500,000

1775

1816

1455

1039

91

1

2

15

1

1

2

32

1

2

2

55

12

91

1

2

81

3402

TPG 400 1750 NEA

400

1,750,000

2017

2121

1697

1212

91

1

2

15

2

32

1

2

2

55

14

91

1

2

81

3528

1

2

HP - 7.4 Amps

TPG 400 2000 NEA

400

2,000,000

2259

2424

1939

1385

99

1

2

15

2

32

1

2

2

55

14

91

1

2

89

3669

TPG 500 2250 NEA

500

2,250,000

2582

2727

2182

1558

110

15

2

32

1

2

2

55

16

91

1

2

100

4277

3

4

HP - 10.2 Amps

TPG 500 2500 NEA

500

2,500,000

2824

3030

2424

1732

110

15

2

32

1

2

2

55

16

91

1

2

100

4419

TPG 600 720 NEA

600

720,000

1178

873

698

499

119

15

1

1

4

32

1

2

2

55

10

76

1

2

109

3667

TPG 600 1000 NEA

600

1,000,000

1450

1212

970

693

119

15

1

1

4

32

1

2

2

55

10

76

1

2

109

3667

1

3

HP - 5.5 Amps

TPG 600 1250 NEA

600

1,250,000

1692

1515

1212

866

119

15

1

1

4

32

1

2

2

55

12

76

1

2

109

3667

TPG 600 1500 NEA

600

1,500,000

1935

1816

1455

1039

119

15

1

1

2

32

1

2

2

55

12

91

1

2

109

3837

TPG 600 1750 NEA

600

1,750,000

2177

2121

1697

1212

119

15

2

32

1

2

2

55

14

91

1

2

109

3837

1

2

HP - 7.4 Amps

TPG 600 2000 NEA

600

2,000,000

2419

2424

1939

1385

119

15

2

32

1

2

2

55

14

91

1

2

109

3837

TPG 600 2250 NEA

600

2,250,000

2662

2727

2182

1558

119

15

2

32

1

2

2

55

16

91

1

2

109

4477

3

4

HP - 10.2 Amps

TPG 600 2500 NEA

600

2,500,000

2904

3030

2424

1732

119

15

2

32

1

2

2

55

16

91

1

2

109

4619

TPG Power Gas Large Volume Commercial Water Heaters

COMMERCIAL

The Expert’s Choice

®

500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com

SPECIFICATIONS

Certified Minimum Installation Clearances to Combustibles:

Front: 18 inches
Back: 0 inches
Sides: 0 inches
Top:

5 inches

A clearance of 24 inches should be maintained from
serviceable parts such as relief valve, power burner, drain
valve and anodes (anodes are located on side above cold
water inlet).

Minimum gas supply pressure: 7 Inches W.C.
Maximum gas supply pressure: 13 Inches W.C.

TPG models are Category I appliances (Fan Assisted) and
require a negative draft. These units should only be
commonly vented with other Category I negative draft
appliances per the latest addition of the National Fuel Gas
Code. An approved/listed Type “B” venting material is
recommended. A negative draft of -0.02˝ to -0.07 is required
in the vent.

TPG models are available in both natural gas and propane. To
order propane, change the “N” to “P” in the model number.
Example: TPG 150 140 

P

EA

ASME

Summary of Contents for Gas

Page 1: ...lectronic flame safeguard control with intermittent spark ignition Also included are main and pilot automatic gas valves plus gas pressure regulators diaphragm air switch for proof of blower operation TPX Low NOX Models are factory standard with modulating fire The burner automatically adjusts the firing rate and the Btu output to maintain precise system temperature control Fully Automatic Control...

Page 2: ... 55 10 761 2 81 3212 TPG 400 1000 NEA 400 1 000 000 1290 1212 970 693 911 2 15 11 4 321 2 2 55 10 761 2 81 3212 1 3 HP 5 5 Amps TPG 400 1250 NEA 400 1 250 000 1532 1515 1212 866 911 2 15 11 4 321 2 2 55 12 761 2 81 3212 TPG 400 1500 NEA 400 1 500 000 1775 1816 1455 1039 911 2 15 11 2 321 2 2 55 12 911 2 81 3402 TPG 400 1750 NEA 400 1 750 000 2017 2121 1697 1212 911 2 15 2 321 2 2 55 14 911 2 81 35...

Page 3: ...0 1130 1212 970 693 831 2 15 11 4 321 2 11 2 60 10 72 73 TPX 200 1250 NEA 200 1 250 000 1372 1515 1212 866 831 2 15 11 4 321 2 11 2 60 12 72 73 TPX 200 1500 NEA 200 1 500 000 1615 1818 1455 1039 831 2 15 11 2 321 2 11 2 60 12 72 73 TPX 300 800 NEA 300 800 000 1016 970 776 554 911 2 14 11 4 261 2 11 2 60 10 72 83 TPX 300 1000 NEA 300 1 000 000 1210 1212 970 693 911 2 14 11 4 261 2 11 2 60 10 72 83 ...

Page 4: ...911 2 14 261 2 11 2 443 4 12 811 2 83 2774 3 4 HP 10 2 Amp TPO 400 600 OEA 411 600 000 4 2 727 582 416 911 2 15 321 2 2 55 8 761 2 81 3207 1 4 HP 4 6 Amp TPO 400 800 OEA 411 800 000 5 7 970 776 554 911 2 15 321 2 2 55 10 761 2 81 3212 TPO 400 1000 OEA 411 1 000 000 7 1 1212 970 693 911 2 15 321 2 2 55 10 761 2 81 3212 1 3 HP 5 5 Amp TPO 400 1250 OEA 411 1 250 000 8 9 1515 1212 866 911 2 15 321 2 2...

Page 5: ...P 4 6 Amp TPD 400 800 ONEA 411 800 000 5 7 970 776 554 911 2 15 11 4 321 2 2 55 10 761 2 81 3212 TPD 400 1000 ONEA 411 1 000 000 7 1 1212 970 693 911 2 15 11 4 321 2 2 55 10 761 2 81 3212 1 3 HP 5 5 Amp TPD 400 1250 ONEA 411 1 250 000 8 9 1515 1212 866 911 2 15 11 4 321 2 2 55 12 761 2 81 3212 TPD 400 1500 ONEA 397 1 500 000 10 7 1816 1455 1039 911 2 15 11 2 321 2 2 55 12 911 2 81 3402 TPD 400 175...

Page 6: ...2 3 handhole cleanouts and carry a National Board stamping The heater s shall be ASME and the entire unit listed by Underwriters Laboratories Controls shall include high temperature limit control manual reset upper and lower thermostats combination temperature and pressure gauge low water cutoff ASME rated temperature and pressure relief valve and barometric draft regulator Control compartment doo...