background image

COMMERCIAL

The Expert’s Choice

®

500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com

Large Volume Power Burner: Gas, Oil & Dual Fuel Commercial Water Heaters

Limited Warranty Outline

If the tank should leak any time during the first three years, under
the terms of the warranty, State Water Heaters will repair or replace
heater; installation, labor, handling and local delivery extra.

– NOTE: This Outline Is NOT A Warranty.

For complete information,

consult the written warranty or State Water Heaters.

TPO – Oil Fired Models: No. 1 or 2 Oil

Multi-annular fuel containment combustor head

Available for firing light fuel oils including diesel

Oil ignition transformer

Integral 2-stage fuel unit

Squirrel cage blower

Oil safety valve

TPD – Dual Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil

Multi-annular fuel containment combustor head

Gas electric pilot and gas ignition transformer

Pilot and main pressure regulators

Air safety switch

Manual fuel selector switch

Integral 2-stage fuel unit

Squirrel cage blower

Meets or exceeds current edition of ASHRAE/IES-90.1-1999.

Low NO

X

– TPX Low NO

X

models meet or exceed current Texas and

California SCAQMD air quality standards.

UL

– Entire unit UL listed (File No. MH11631).

Glass-Lined Tank

– Exclusive corrosion protection with glass-

lining on all interior surfaces. Multiple anodes provide even more
corrosion protection.

ASME Construction Standard

– 160 PSI working pressure on all models.

Powered Gas Burner

– Powered burner has electronic flame

safeguard control with intermittent spark ignition. Also included are
main and pilot automatic gas valves plus gas pressure regulators,
diaphragm air switch for proof of blower operation.

TPX Low NO

X

Models are factory standard with modulating fire.

The burner automatically adjusts the firing rate and the Btu output
to maintain precise system temperature control.

Fully Automatic Controls With Safety Shutoff

– High temperature

limit control (manual reset). ASME rated temperature and pressure
relief valve. Hinged door control compartment for ease of access. Two
thermostats, upper and lower, for accurate temperature control.
Standard control is for 120˚F - 180˚F water service.

Jacket And Insulation

– Heavy gauge steel with baked powder coat

finish. Insulated with high-density foam insulation that meets or
exceeds all required standards.

Professional Start-Up Service Furnished To Assure Most Efficient
Combustion And Safe Initial Start-Up.

Other Features

Two layers of high temperature ceramic fiber insulation in
combustion chamber

Flame inspection port opening

Mounted on rugged channel iron skids

Combination temperature and pressure gauge

Low water cutoff

ASME rated temperature and pressure relief valve

Barometric draft regulator

Two cleanout inspection openings

120 volt control circuit

Drain valve

Removable lifting lugs

Options

Factory Mutual approved control arrangement

Industrial Risk Insurance (IRI Gas Train)

5 year or 10 year limited warranty

High or low water pressure switch

180°F water service thermostats

A.G.A. rated T & P Valve

Modular graphic burner systems management on heaters with
270,000 Btu input and over

Combustion Air intake Adapter

Summary of Contents for Gas

Page 1: ...lectronic flame safeguard control with intermittent spark ignition Also included are main and pilot automatic gas valves plus gas pressure regulators diaphragm air switch for proof of blower operation TPX Low NOX Models are factory standard with modulating fire The burner automatically adjusts the firing rate and the Btu output to maintain precise system temperature control Fully Automatic Control...

Page 2: ... 55 10 761 2 81 3212 TPG 400 1000 NEA 400 1 000 000 1290 1212 970 693 911 2 15 11 4 321 2 2 55 10 761 2 81 3212 1 3 HP 5 5 Amps TPG 400 1250 NEA 400 1 250 000 1532 1515 1212 866 911 2 15 11 4 321 2 2 55 12 761 2 81 3212 TPG 400 1500 NEA 400 1 500 000 1775 1816 1455 1039 911 2 15 11 2 321 2 2 55 12 911 2 81 3402 TPG 400 1750 NEA 400 1 750 000 2017 2121 1697 1212 911 2 15 2 321 2 2 55 14 911 2 81 35...

Page 3: ...0 1130 1212 970 693 831 2 15 11 4 321 2 11 2 60 10 72 73 TPX 200 1250 NEA 200 1 250 000 1372 1515 1212 866 831 2 15 11 4 321 2 11 2 60 12 72 73 TPX 200 1500 NEA 200 1 500 000 1615 1818 1455 1039 831 2 15 11 2 321 2 11 2 60 12 72 73 TPX 300 800 NEA 300 800 000 1016 970 776 554 911 2 14 11 4 261 2 11 2 60 10 72 83 TPX 300 1000 NEA 300 1 000 000 1210 1212 970 693 911 2 14 11 4 261 2 11 2 60 10 72 83 ...

Page 4: ...911 2 14 261 2 11 2 443 4 12 811 2 83 2774 3 4 HP 10 2 Amp TPO 400 600 OEA 411 600 000 4 2 727 582 416 911 2 15 321 2 2 55 8 761 2 81 3207 1 4 HP 4 6 Amp TPO 400 800 OEA 411 800 000 5 7 970 776 554 911 2 15 321 2 2 55 10 761 2 81 3212 TPO 400 1000 OEA 411 1 000 000 7 1 1212 970 693 911 2 15 321 2 2 55 10 761 2 81 3212 1 3 HP 5 5 Amp TPO 400 1250 OEA 411 1 250 000 8 9 1515 1212 866 911 2 15 321 2 2...

Page 5: ...P 4 6 Amp TPD 400 800 ONEA 411 800 000 5 7 970 776 554 911 2 15 11 4 321 2 2 55 10 761 2 81 3212 TPD 400 1000 ONEA 411 1 000 000 7 1 1212 970 693 911 2 15 11 4 321 2 2 55 10 761 2 81 3212 1 3 HP 5 5 Amp TPD 400 1250 ONEA 411 1 250 000 8 9 1515 1212 866 911 2 15 11 4 321 2 2 55 12 761 2 81 3212 TPD 400 1500 ONEA 397 1 500 000 10 7 1816 1455 1039 911 2 15 11 2 321 2 2 55 12 911 2 81 3402 TPD 400 175...

Page 6: ...2 3 handhole cleanouts and carry a National Board stamping The heater s shall be ASME and the entire unit listed by Underwriters Laboratories Controls shall include high temperature limit control manual reset upper and lower thermostats combination temperature and pressure gauge low water cutoff ASME rated temperature and pressure relief valve and barometric draft regulator Control compartment doo...

Reviews: