background image

For more information on State On-Demand Water Heaters, contact: 
State Water Heaters 
500 Tennessee Waltz Parkway  
Ashland City, TN 37015

800-365-0024 Toll-free USA

www.statewaterheaters.com

SRGSS02007

April 2010R

 

Specifications 

Specifications are subject to change without prior notice. 

The maximum inlet gas pressure must not exceed the value specified by the manufacturer.  The minimum value 
listed is for the purpose of input adjustment. 

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. 

** for commercial and hydronic applications requiring higher temperatures 

Model 

305

200/201 Series 

505

 200/201 Series

705 

Minimum Gas Consumption Btu/h  

15,000   

19,000 

Maximum Gas Consumption Btu/h  

180,000 

199,000 Natural Gas 

190,000 Propane Gas  

237,000 

Hot water capacity (Min - Max) * 

0.6 - 7.5 GPM 

(2.3 - 28.4 L/min) 

0.6 - 9.4 GPM 

(2.3 - 35.5 L/min) 

0.6 - 9.8 GPM    

(2.3 - 37 L/min) 

Interior Hot Water Capacity (45° rise)

 

6.6 GPM (25.0 L/min)  

7.4 GPM (28.0 L/min)  

Natural Gas 

7.1 GPM (26.9 L/min)  

Propane Gas 

8.8 GPM   (33.5 L/min) 

Default Temperature Setting (no controller) 

 

120º F (49º C)

Exterior Hot Water Capacity (45° rise) 

7.4 GPM (28.0 L/min)

8.7 GPM (33.1 L/min)

 

Setting 

 

Maximum Temp Setting (Commercial**) 

160º F (71º C)   

185º F (85º C)    

 

 

 

 

Minimum Temperature Setting  

98º F (37º C) 

 

 

Efficiency Rating / Energy Factor 

84% / .82 E.F.

84%/N.A.

 

 

Electrical 
Consumption  

Normal (Indoor/Outdoor) 

 

65 W/50 W 

 

79 W/55 W 

99 W/72 W 

 

Anti-frost Protection  

100 W  

116 W 

 

 

Minimum Gas Supply 
Pressure  

Natural Gas  

5.0 inch W.C. 

 

 

Maximum Gas Supply 
Pressure  

Natural Gas  

10.5 inch W.C. 

Propane  

13.5 inch W.C. 

Type of Appliance  

Direct Vent, Temperature controlled continuous flow gas hot water system.  

 

 

Approved Gas Type  

Natural Gas or Propane - Ensure unit matches gas type it's being installed on.  

 

 

Ignition System  

Direct Electronic Ignition  

 

 

Water Temperature Control  

Simulation Feedforward and Feedback.  

y  

 

Maximum Water Supply Pressure  

150 PSI  

 

 

Energy Star® Qualified 

Yes 

Yes 

No 

6.6 GPM (25.0 L/min) 

Temperature Controller Default Temperature 

104º F (40º C)

Maximum Temp Setting (Residential)

Selectable at 120º F (49º C) or at 140º F (60º C)

140º F (60º C)

Weight (Indoor/Outdoor) 

Indoor Unit 50 lb (23kg) Outdoor Unit 46 lb (21 kg) 

55 lb (25 kg) 

Noise level 

49dB

Standby 2 

Propane 

8.0 inch W.C.

Operation 

With or without temperature controls, mounted in kitchen, bathroom, etc. 

Connections 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"

Electric Connections 

Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital) 

Water Suppl Pressure 

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum 

performance) 

Temperature Control Cable 

Non-Polarized Two Core Cable (Minimum 22 AWG)

By-Pass Control 

Fixed 

Electronic 

 

 

 

 

 

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

0

25

50

75

100

125

150

Water Flow (gpm) 

delta T - Temperature Rise (ºF) 

705 

505 

305 

ANSZ21.10.3 

 CSA 4.3

224259 SRGSS02007   4

224259 SRGSS02007   4

4/23/10   12:35:14 PM

4/23/10   12:35:14 PM

Reviews: