4.
Connect the Power cable to the Power Source. Upon connection, the display will show the power
logo, as shown in Figure 5-1-1-4.
Figure 5-1-1-4 LOGO
DANGER
(1)
The power supply requirement is 85-264VAC 50 / 60Hz
(2)
If you work on a roof, tower or other high structure or use a ladder or scaffold to access the
work site, follow these precautions to prevent personal injury or death:
❖
Walk only on sound roof structures.
❖
Ensure that the antenna assembly and installation surface are structurally sound so that
they can support all loads (equipment weight, ice, and wind).
❖
Use safety equipment (for example, a lifeline) appropriate for the work location.
❖
Follow all manufacturer safety precautions for all safety and other equipment used.
❖
Perform as many procedures as possible on the ground.
(3)
Do not work in high wind or rain; or if a storm, lightning, or other adverse weather conditions
are either present or approaching.
(4)
Do not connect the other side of the power cable to the power source until the terminal
installation completion.
5.
Deploy the Terminal, move the locking tab downward firstly, and the button will automatically move
downward, then the Terminal is deployed. As shown in Figure 5-1-1-5 and Figure 5-1-1-6.
Figure 5-1-1-5 Deploy the Terminal